United Kingdom

Build Check

Hayloaders Works, Wotton Road, Brill, HP18 9UB, Aylesbury, United Kingdom

UKAS|4044ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
8
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Build Check?

Claim this profile to keep it accurate.

Register record

UKASRefreshed
4044Withdrawn

Certificates and scope

1
UKAS

ISO/IEC 17025

Withdrawn

4044

View scope

Accredited scope, certificate 4044

LineDisciplineMethodMatrixRange
1-ISO/IEC 17025:2017--
2Electrical TestingBS EN ISO 10077-1:2017 BS EN ISO 10077-2:2017 BS EN 673:2011 Lab WINDOWS and DOORS Air permeability BS EN 1026:2016 A Watertightness BS EN 1027:2000 BS EN 1027: 2016 A Resistance to wind load BS EN 12211:2016 A Weathertightness BS 6375-1:2015 A WINDOWS Operating forces BS 6375-2:2009 BS EN 12046-1:2020 A Static torsion BS 6375-2:2009 BS EN 14609:2004 A Racking BS 6375-2:2009 BS EN 14608:2004 A Load bearing capacity of safety devices BS 6375-2:2009 BS EN 14609:2004 As modified by in-house procedure OP208 A DOORS Operating forces BS 6375-2:2009 BS EN 12046-2:2000 BS EN 12217:2003 A Vertical load BS 6375-2:2009 BS EN 947:1999 BS EN 1192:2000; BS 6375-1; BS 6375-2; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 10077-1:2017 BS EN ISO 10077-2:2017 BS EN 673:2011 Lab WINDOWS and DOORS Air permeability BS EN 1026:2016 A Watertightness BS EN 1027:2000 BS EN 1027: 2016 A Resistance to wind load BS EN 12211:2016 A Weathertightness BS 6375-1:2015 A WINDOWS Operating forces BS 6375-2:2009 BS EN 12046-1:2020 A Static torsion BS 6375-2:2009 BS EN 14609:2004 A Racking BS 6375-2:2009 BS EN 14608:2004 A Load bearing capacity of safety devices BS 6375-2:2009 BS EN 14609:2004 As modified by in-house procedure OP208 A DOORS Operating forces BS 6375-2:2009 BS EN 12046-2:2000 BS EN 12217:2003 A Vertical load BS 6375-2:2009 BS EN 947:1999 BS EN 1192:2000Air-
3Mechanical TestingBS EN 948:1999 BS EN 1192:2000 A Soft and heavy body impact BS 6375-2:2009 BS EN 13049:2003 BS EN 949:1999 BS EN 1192:2000 A Hard body impact BS 6375-2:2009 BS EN 950:1999 BS EN 1192:2000 A Load bearing capacity of safety devices BS 6375-2:2009 BS EN 948:1999 as modified by Documented In-House Method No OP208 A DOOR AND SHUTTER ASSEMBLIES Smoke control BS EN 1634-3:2004; BS 6375-2; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; In-House Method NoDOORS; DOOR AND SHUTTER ASSEMBLIES; DOORSETS-
4Materials TestingPAS 24:2022; PAS 24:2016; ISO/IEC 17025:2017DOORSETS; WINDOWS-
5Materials TestingBS EN 13051:2001 Site Hose Test AAMA 501; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025Water-
6Electrical TestingBS EN 14019:2016; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025Drinking water-
7mechanicalEN 14351-1:2006+A2:2016Doors, windows, shutters, blinds, gates and related building hardware-
8mechanicalEN 14351-1:2006+A2:2016Doors, windows, shutters, blinds, gates and related building hardware-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Hayloaders Works, Wotton Road, Brill, Aylesbury, HP18 9UB, GB

51.81614, -0.81304

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.