ECOSUD S.r.l.
Zona Industriale Val Basento snc, 75015, Pisticci, Italy
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at ECOSUD S.r.l.?
Claim this profile to keep it accurate.
Register record
- ACCREDIARefreshed
- 02162Active
Accredited standards
6Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
APAT CNR IRSA 1030 Man 29 2003Name not checked yet
APAT CNR IRSA 1030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2100 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; ISO 5667-5:2006; UNI EN ISO 19458:2006; UNI EN ISO 5814:2013; UNI 10370:2010; ISO 5667-10:2020; ISO 5667-11:2009; UNI 10802:2023
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
APAT CNR IRSA 1030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2100 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; ISO 5667-5:2006; UNI EN ISO 19458:2006; UNI EN ISO 5814:2013; UNI 10370:2010; ISO 5667-10:2020; ISO 5667-11:2009; UNI 10802:2023
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
APAT CNR IRSA 1030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2100 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; ISO 5667-5:2006; UNI EN ISO 19458:2006; UNI EN ISO 5814:2013; UNI 10370:2010; ISO 5667-10:2020; ISO 5667-11:2009; UNI 10802:2023
ISO 5667-11Water quality - Sampling - Part 11: Guidance on sampling of groundwaters
APAT CNR IRSA 1030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2100 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; ISO 5667-5:2006; UNI EN ISO 19458:2006; UNI EN ISO 5814:2013; UNI 10370:2010; ISO 5667-10:2020; ISO 5667-11:2009; UNI 10802:2023
ISO 5814Water quality - Determination of dissolved oxygen - Electrochemical probe method
APAT CNR IRSA 1030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2100 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; ISO 5667-5:2006; UNI EN ISO 19458:2006; UNI EN ISO 5814:2013; UNI 10370:2010; ISO 5667-10:2020; ISO 5667-11:2009; UNI 10802:2023
ISO 19458Water quality - Sampling for microbiological analysis
APAT CNR IRSA 1030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2100 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; ISO 5667-5:2006; UNI EN ISO 19458:2006; UNI EN ISO 5814:2013; UNI 10370:2010; ISO 5667-10:2020; ISO 5667-11:2009; UNI 10802:2023
Scope as published by ACCREDIA
1 line
ISO/IEC 17025
Active02162
Accredited scope, certificate 02162
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | APAT CNR IRSA 1030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2100 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; ISO 5667-5:2006; UNI EN ISO 19458:2006; UNI EN ISO 5814:2013; UNI 10370:2010; ISO 5667-10:2020; ISO 5667-11:2009; UNI 10802:2023 | Waste water | 1 to 13 unità di pH |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- S.C.A SERVIZI CONSULENZA ANALISI AMBIENTALIPisticci · under 1 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003Waste water
- STUDIO ANALISI CHIMICHE E AMBIENTALIPisticci · under 1 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003Waste water
- HYDROLABFerrandina · ~15 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003Waste water
- TECNOLAB della Dott.ssa Serino CaterinaAltamura · ~48 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003Waste water
- GEO LAB S.r.l.Rende · ~121 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003Waste water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.