Registers refreshed 2026-11-20.See refresh dates
Spain

BUQUELAND EMPRESA EUROPEA DE LA INGENIERÍA DE LA CALIDAD

C/ Salvador, nº 3, entresuelo, 15500, Fene, Spain

ENAC 1367/LE2565ISO/IEC 17025Register refreshed 46 days ago

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
8
ENAC certificate
1
Site in our directory
1
ENAC accredited scope

What this lab is accredited for

Our reading of the ENAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 8 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 3452-1Non-destructive testing - Penetrant testing - Part 1: General principles
ISO 5817Welding - Fusion-welded joints in steel, nickel, titanium and their alloys (beam welding excluded) - Quality levels for imperfections
ISO 11666Non-destructive testing of welds - Ultrasonic testing - Acceptance levels
ISO 17637Non-destructive testing of welds - Visual testing of fusion-welded joints
ISO 17638Non-destructive testing of welds - Magnetic particle testing
ISO 17640Non-destructive testing of welds - Ultrasonic testing - Techniques, testing levels, and assessment
ISO 23277Non-destructive testing of welds - Penetrant testing - Acceptance levels
ISO 23278Non-destructive testing of welds - Magnetic particle testing - Acceptance levels

Read from the scope as published by ENAC. Register refreshed 2026-10-10.

Scope as published by ENAC

2 lines
ENAC

ISO/IEC 17025

Active

1367/LE2565

View scope

Accredited scope, certificate 1367/LE2565

LineMethodMatrixRange
1UNE-EN ISO 3452-1; UNE-EN ISO 23277; UNE-EN ISO 17638; UNE-EN ISO 23278; UNE-EN ISO 17640; UNE-EN ISO 11666Uniones soldadas-
2UNE-EN ISO 17637; UNE-EN ISO 5817--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

C/ Salvador, nº 3, entresuelo, Fene, 15500, ES

43.45539, -8.16711

Open in Maps

Accreditation data refreshed from the ENAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.