Registers refreshed 2026-11-08.See refresh dates
United States

Miller-Weber of Texas operated by LK Industries Products

1999 Tellepsen Street, 77023, Houston, TX, United States

Visit website
A2LA 5955.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 5955.01 · 3 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5955.01) Revised 02/27/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 MILLER-WEBER OF TEXAS OPERATED BY LK INDUSTRIES PRODUCTS, LLC 1999 Tellepsen St Houston, TX 77023 David Huber Phone: 713 926 2623 CALIBRATION Valid To: March 31, 2026 Certificate Number: 5955.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Fluid Quantities Parameter/Equipment Range CMC2, 5, 7 (±) Comments Density – Measure & Measuring Equipment 4 (0.625 to 1.910) SG (-1 to 101)° API 0.000 31 SG + 0.1R 0.052° API + 0.1R Comparison to standard hydrometers Volumetric Apparatus – Centrifuge Tubes Other Apparatus Up to 3 ml Up to 100 ml 0.0079 ml 0.044 ml Balance II. Thermodynamics Parameter/Equipment Range CMC2, 7 (±) Comments Temperature – Measure & Measuring Equipment 4 (-80 to -40) °C (-40 to 5) °C 0.022 °C (22 mK) 0.016 °C (16 mK) Hart 5628 precision platinum resistance thermometer
0.625 to 1.91 SG
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5955.01) Revised 02/27/2026 Page 2 of 2 Parameter/Equipment Range CMC2, 7 (±) Comments Temperature – Measure & Measuring Equipment 3 (cont) (5 to 95) °C (95 to 205) °C (205 to 305) °C (305 to 405) °C (-20 to 150) °C 0.013 °C (13 mK) 0.018 °C (18 mK) 0.034 °C (34 mK) 0.035 °C (35 mK) 0.065 °C Hart 1560 blackstack, Hart 2560 SPRT module FlukeCal 1551A Stik thermometer III. Time & Frequency Parameter/Equipment Range CMC2, 7 (±) Comments Rotational Speed – Measure & Measuring Equipment 3 Up to 6000 rpm 1.7 rpm Laser tachometer ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 All comparison temperature calibrations are performed in circulating liquid baths. 5 In the statement of CMC, R is the numerical value of the resolution of the unit under test. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 The type of instrument or material being calibrate d is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1999 Tellepsen Street, Houston, TX, 77023, US

29.75894, -95.36770

Open in Maps

Accreditation data refreshed from the A2LA register on .