What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 5955.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5955.01) Revised 02/27/2026 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
MILLER-WEBER OF TEXAS OPERATED BY LK INDUSTRIES PRODUCTS, LLC
1999 Tellepsen St
Houston, TX 77023
David Huber Phone: 713 926 2623
CALIBRATION
Valid To: March 31, 2026 Certificate Number: 5955.01
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following calibrations
1, 6:
I. Fluid Quantities
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Density – Measure &
Measuring Equipment
4
(0.625 to 1.910) SG
(-1 to 101)° API
0.000 31 SG + 0.1R
0.052° API + 0.1R
Comparison to
standard hydrometers
Volumetric Apparatus –
Centrifuge Tubes
Other Apparatus
Up to 3 ml
Up to 100 ml
0.0079 ml
0.044 ml
Balance
II. Thermodynamics
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Temperature – Measure &
Measuring Equipment
4
(-80 to -40) °C
(-40 to 5) °C
0.022 °C (22 mK)
0.016 °C (16 mK)
Hart 5628 precision
platinum resistance
thermometer | 0.625 to 1.91 SG |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5955.01) Revised 02/27/2026 Page 2 of 2
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Temperature – Measure &
Measuring Equipment
3
(cont)
(5 to 95) °C
(95 to 205) °C
(205 to 305) °C
(305 to 405) °C
(-20 to 150) °C
0.013 °C (13 mK)
0.018 °C (18 mK)
0.034 °C (34 mK)
0.035 °C (35 mK)
0.065 °C
Hart 1560 blackstack, Hart
2560 SPRT module
FlukeCal 1551A Stik
thermometer
III. Time & Frequency
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Rotational Speed –
Measure & Measuring
Equipment
3
Up to 6000 rpm
1.7 rpm
Laser tachometer
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be
considered and this, on its own, could result in the actual measurement uncertainty achievable on a
customer’s site being larger than the CMC.
4 All comparison temperature calibrations are performed in circulating liquid baths.
5 In the statement of CMC, R is the numerical value of the resolution of the unit under test.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The type of instrument or material being calibrate d is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.