Registers refreshed 2026-11-20.See refresh dates
Canada

Durham Pattern & Model

BOWMANVILLE, Canada

Visit website
A2LA 2630.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 2630.01 · 3 lines

LineMethodMatrixRange
1-Steel
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2630.01) 09/17/2024 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 DURHAM PATTERN & MODEL LTD. 22 Caristrap Street Bowmanville, Ontario L1C 3Y7, Canada Brad McIlroy Phone: 905 623 8700 CALIBRATION Valid To: September 30, 2026 Certificate Number: 2630.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Testing/Calibration3 Parameter/Equipment Range CMC2, 4 (±) Comments Dimensional Measurement (3D) – Fixture and Attribute Gauges (3D) Materials: Steel Aluminum Grey Fixture Plank Brown Fixture Plank Materials: Steel Aluminum Grey Fixture Plank Brown Fixture Plank (X, Y, Z) Up To: (1205, 2005, 1005) mm (900, 1600, 600) mm (6.2 + 19L) µm (6.2 + 37L) µm (6.2 + 41L) µm (6.2 + 45L) µm (5.8 + 18L) µm (5.8 + 36L) µm (5.8 + 40L) µm (5.8 + 44L) µm CMM used as measuring/ test equipment: Mitutoyo Bright-A1220 Mitutoyo Bright-A916 Dimensional Measurement (1D) – Attribute Pins and Gauges Up to 76.2 mm Up to 152.4 mm 4.1 µm 19 µm Micrometers used as measuring/test equipment Calipers used as measuring/testing equipment
to 1205 mm
2-Steel
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2630.01) 09/17/2024 Page 2 of 2 Parameter/Equipment Range CMC2, 4 (±) Comments Dimensional Measurement (3D) – Fixtures and Attribute Gauges (3D) Materials: Steel Aluminum Grey Fixture Plank Brown Fixture Plank (X, Y, Z) up to: (500, 400, 400) mm (4.4 + 14L) µm (4.4 + 30L) µm (4.4 + 34L) µm (4.4 + 39L) µm CMM used as measuring/ test equipment: Mitutoyo CRTA-544 ____________________________________________ 1 This laboratory offers commercial dimensional testing/calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 4 In the statement of CMC, L is the numerical value of the nominal length of the measuring device in unit of meter. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
to 500 mm
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.