Twin Peaks
37-39 30th street, 11101, Long Island City, NY, United States
Visit website- Accredited standards
- 7
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 7 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM E94
ASTM E164
ASTM E329
ASTM E446
ASTM E587
ASTM E747
AWS D1.1
BC 1705.38 (2022); BC 1705.39 (2022); BC 1705.26 (2022); BC 1705.5.6 (2022); BC 1705.25.4 (2022); BC 1817 (2022); AWS D1.1; ASME B31.1; ASME B31.3; ASTM E164; ASTM E587; AWS D1.1; ASME B31.1; ASME B31.3; AWS D1.1; ASME B31.1; ASME B31.3; ASTM E94; ASTM E446; ASTM E747; AWS D1.1; ASME B31.1; ASME B31.3; API 1104; ASTM E329
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
8 lines
ISO/IEC 17020
Active5964.01
The scope document we hold says it was valid until 2026-10-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 5964.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17020:2012; Special Inspections Rules of the City of New York, 1RCNY 101-06, Appendix A; New York City Building Codes; The International Building Codes (IBC) 2014 and the 2022 Building Code | - | - |
| 2 | BC 1704.30 (2014); BC 1024.8 (2014); BC 1024.8 (2014); BC 1705.35 (2022); BC 1025.8 (2022); RCNY 101-07; NYCBC 1704; BC 1704.11, (2014); BC 1704.12 (2014); BC 1705.14 (2022); BC 1705.15 (2022); BC 1704.15 (2014); BC 909 (2014); BC 1705.16 (2022); BC 1704.23, (2014); BC 1704.24 (2014); BC 1705.29 (2022); BC1705.30 (2022); BC 1704.27 (2014); BC 1705.17 (2022; BC 1704.31, (2014); BC 1707.7 (2014); BC 2702 (2014); BC 1705.36 (2022); BC 1704.16 (2014); BC 507.16 (2014); MC 1011, 1018 and 1208 (2014); BC 1705.21 (2022); BC 1704.17 (2014); BC 1705.22 (2022); BC 1704.21, (2014); BC 1704.21.1.2 (2014); BC 1704.22 (2014); BC 1705.27.1.2 (2022); BC 1705.27.2 (2022); BC 1705.28 (2022) | - | - |
| 3 | BC 1704.25 (2014); BC 1707.7 (2014); BC 1705.31 (2022); BC 1704.3.1; BC 1704.18 (2014); BC 1704.18 (2014); BC 1704.19 (2014); BC 1704.28 (2014); BC 1705.21 (2022); BC 1705.23 (2022); BC 1705.24 (2022); BC 1705.33 (2022); 2 RCNY 25 – BSA RULE; BC 1704.3.2 (2014); BC 1705.2.2 (2022); BC 1704.3.3 (2014); BC 1705.2.3 (2022); BC 1704.3.2 (2014); BC 1704.3.4; (2014); BC 1705.2.6 (2022); BC 1704.4; (2014); BC 1704.4.1 (2014); BC 1704.4.2 (2014); Table 1704.4 (2014); BC 1705.3 (2022); BC 1704.4 (2014); BC 1705.3 (2022); BC 1704.5 (2014); BC 1705.4 (2022) | - | - |
| 4 | BC 1704.6.1 (2014); BC 1704.6.2 (2014); BC 1704.6.3 (2014); BC 1705.5.1 (2022); BC 1705.5.2 (2022); BC 1705.5.3 (2022); BC 1704.7.1 (2014); BC 1705.5 (2022); BC 1704.7.2, (2014); BC 1704.7.3 (2014); BC 1803.5 (2014); BC 1705.5 (2022); BC 1704.7.4 (2014); BC 1705.6 (2022); BC 1704.8 (2014); BC 1808 (2014); BC 1809 (2014); BC 1810 (2014); BC 1705.6 (2022); BC 1704.9 (2014); BC 1705.19 (2022); BC 1704.20.3 (2014); BC 1814 (2014); BC 1814 (2014); BC 1704.8.5; BC 1704.20.1 (2014); BC 1704.20.4 (2014); BC 1704.20.5 (2014); BC 1705.25.6 (2022); BC 1705.25.5.1 (2022); BC 1705.25.1 (2022) | - | - |
| 5 | BC 1704.20.2 (2014); BC 1705.25.3 (2022); BC 1707.8 (2014); BC 1705.12.5 (2022); BC 1704.32 (2014); BC 1705.37 (2022); BC 1704.14 (2014); BC 1705.2.7 (2022); BC 1708.8 (2022); BC 1705.12.1 (2022); BC 1705.12.2 (2022); BC 1705.12.3 (2022); BC 1705.12.4 (2022); BC 1705.25.2 (2022); BC 1705.26 (2022) | - | - |
| 6 | BC 1705.38 (2022); BC 1705.39 (2022); BC 1705.26 (2022); BC 1705.5.6 (2022); BC 1705.25.4 (2022); BC 1817 (2022); AWS D1.1; ASME B31.1; ASME B31.3; ASTM E164; ASTM E587; AWS D1.1; ASME B31.1; ASME B31.3; AWS D1.1; ASME B31.1; ASME B31.3; ASTM E94; ASTM E446; ASTM E747; AWS D1.1; ASME B31.1; ASME B31.3; API 1104; ASTM E329 | - | - |
| 7 | BC 109.3.1; BC 109.3.5; AC 28.116.2.1; AC 28.116.2.2; BC 109.3.2; BC G105.3; BC 109.3.3; BC 109.3.4; BC 109.3.6; AC 28- 116.2.4.2; AC 28- 116.2.2 | - | - |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. For the inspections to which this accreditation applies, please refer to the organization’s Inspection Body Scope of Accreditation.
Accredited Inspection Body
A2LA has accredited
TWIN PEAKS INC.
Long Island City, NY
for technical competence in and compliance with the
Inspection Body Accreditation Program
This inspection body is accredited in accordance with the recognized International Standard
ISO/IEC 17020:2012 Conformity Assessment – Requirements for the operation of various types of bodies
performing inspection. This accreditation demonstrates technical competence for a defined scope and
the operation of a quality management system.
Presented this 26th day of August 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 5964.01
Valid to October 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Delta Testing Inc. DBA Delta TestingMount Vernon, NY · ~21 kmA2LAShares 1 accredited test methodAWS D1.1
- Sky Testing ServicesWestbury, NY · ~30 kmA2LAShares 1 accredited test methodAWS D1.1
- Metric Consulting & InspectionHicksville, NY · ~35 kmA2LAShares 1 accredited test methodAWS D1.1
- Skytesting CivilBohemia, NY · ~70 kmA2LAShares 1 accredited test methodAWS D1.1
- Tensile Testing MetallurgicalCleveland, OH · ~654 kmA2LAShares 1 accredited test methodAWS D1.1
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.