Skyships Automotive
31 Springfield Lyons Approach, CM2 5LB, Chelmsford, United Kingdom
Visit website- Accredited standards
- 9
- UKAS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the UKAS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 9 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 7637-0Road vehicles - Electrical disturbance by conduction and coupling - Part 0: Definitions and general
ISO 7637-1Road vehicles - Electrical disturbances from conduction and coupling - Part 1: Vocabulary and general considerations
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply linesExclusion
Limits written next to it
ISO 7637-3:2016 (excluding DCC
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methodsExclusion
Limits written next to it
ISO 11452-4:2020 (excluding
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
ISO/IEC 17025:2017 Skyships Automotive Limited Issue No: 001 Issue date: 05 August 2024 Skyships Automotive Limited 31 Springfield Lyons Approach Chelmsford CM2 5; ISO 11452-2:2004 ISO 11452-2:1995 ISO 11452-2:20191 Absorber Lined Chamber 400 MHz to 6 GHz up to 600 V/m ISO 11452-9:2012 ISO 11452-9:20211 1; ISO 7637-0:1990 ISO 7637-1:1990 ISO 7637-1:2015 ISO 7637-2:1990; ISO 7637-2:2011 ISO 7637-3: 2007 ISO 7637-3:2016; ISO 11452-2:2012
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 11452-4:2001 ISO 11452-4:2005 ISO 11452-4:2020; ISO 10605:2001 ISO 10605:2008; ISO 11452-8:2015; IEC 17025
Read from the scope as published by UKAS. Register refreshed 2026-11-20.
Scope as published by UKAS
2 lines
ISO/IEC 17025
Active29498
Accredited scope, certificate 29498
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 Skyships Automotive Limited Issue No: 001 Issue date: 05 August 2024 Skyships Automotive Limited 31 Springfield Lyons Approach Chelmsford CM2 5; ISO 11452-2:2004 ISO 11452-2:1995 ISO 11452-2:20191 Absorber Lined Chamber 400 MHz to 6 GHz up to 600 V/m ISO 11452-9:2012 ISO 11452-9:20211 1; ISO 7637-0:1990 ISO 7637-1:1990 ISO 7637-1:2015 ISO 7637-2:1990; ISO 7637-2:2011 ISO 7637-3: 2007 ISO 7637-3:2016; ISO 11452-2:2012 | Motor Vehicle’s Electronics including: Multi Media, Drive Information and Body Safety, Climate Control, Lighting, Energy Transformation Systems; ESA Component Modules only (excludes EV & REESS high voltage systems) | See scope document |
| 2 | ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 11452-4:2001 ISO 11452-4:2005 ISO 11452-4:2020; ISO 10605:2001 ISO 10605:2008; ISO 11452-8:2015; IEC 17025 | - | to 15 kV |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the UKAS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.