Registers refreshed 2026-11-08.See refresh dates
Spain

EMPRESA MIXTA VALENCIANA DE AGUAS, S.A. (LABORATORIO ETAP LA PRESA)

Carretera Quart-Domeño Km.7 desvio derecha, 46940, Manises, Spain

Visit website
ENAC 1071/LE2088ISO/IEC 17025Register refreshed 2026-10-10

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
13
ENAC certificate
1
Site in our directory
1
ENAC accredited scope

What this lab is accredited for

Our reading of the ENAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 13 standard numbers and the 12 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO11
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 9963-1Water quality - Determination of alkalinity - Part 1: Determination of total and composite alkalinity
ISO 10705-2Water quality - Detection and enumeration of bacteriophages - Part 2: Enumeration of somatic coliphages
ISO 10705-3Water quality - Detection and enumeration of bacteriophages - Part 3: Validation of methods for concentration of bacteriophages from water
ISO 11731Water quality - Enumeration of Legionella

Certificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.

ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
Other standards2
ASTM D1426
EN 27888Water quality - Determination of electrical conductivity

Read from the scope as published by ENAC. Register refreshed 2026-10-10.

Scope as published by ENAC

3 lines
ENAC

ISO/IEC 17025

Active

1071/LE2088

View scope

Accredited scope, certificate 1071/LE2088

LineMethodMatrixRange
1UNE-EN ISO/IEC 17025:2017; SM 4500-H+ B; UNE-EN 27888Aguas de consumo; Aguas continentales tratada no destinadas al consumo-
2UNE-EN ISO 7027-1; UNE-EN ISO 9963-1; UNE 77013; SM 4500-Cl–B; SM 2340 C; ASTM D1426; UNE-EN ISO 7887; SM 4500-NO2–B; SM 4500-NO3–B; SM 3500-Mg B; SM 4500-Cl G; UNE-EN-ISO 6222Aguas de consumo; Aguas continentales tratada no destinadas al consumo-
3UNE-EN ISO 9308-2; UNE-EN ISO 7899-2; UNE-EN ISO 14189; UNE-EN ISO 16266; UNE-EN ISO 10705-2; UNE-EN ISO 10705-3; UNE-EN ISO 11731; PE-EMILAB-205; PE-EMILAB-220; EPA: Method 1623.1Aguas de consumo-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Carretera Quart-Domeño Km.7 desvio derecha, Manises, 46940, ES

39.49299, -0.46214

Open in Maps

Accreditation data refreshed from the ENAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.