Registers refreshed 2026-11-20.See refresh dates
Mexico

Marelli Automotive Lighting LLC - Juarez Test

AVE. DEL CHARRO 1750 NORTE, COL. PARTIDO ESCOBEDO, CIUDAD JUAREZ, 32330, Mexico, CIUDAD JUAREZ, Mexico

Visit website
A2LA 2203.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
1
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

2203.01

The scope document we hold says it was valid until 2026-08-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 2203.01

LineMethodMatrixRange
1FMVSS 571.108 S14.6.6; GM Method: GMW14906-07; GMW14906-09; GMW14906-10; GMW14906-12; GMW14906-13; GMW14906-14; GMW14906-15; VW Method: TL 909-92 para. 2.2.2; TL 909-92 para. 2.2.7.1; TL 909-92 para. 4.2.2; TL 909-92 para. 4.2.7.1; TL 909-92 para. 4.2.7.2; TL 909-92 para. 4.2.11; TL 909-05 para. 4.6; TL 909-13 para 4.9; Ford Method: SDS EX-0009; SDS EX-0012; FCA Method: PF-90078 para 5.3.1; PF-90165 para 5.3.1; PF-90165 para 5.3.2; PF-90165 para 5.3.3; PF-90165 para 5.3.4; MBN LV-124 Sec. K-05; VW Method: TL 909-05 para. 4.1; TL909-13 para 4.11; FMVSS 571.108 S14.6.7; FCA Method: PF-90165 para 5.8.1; VW Method: TL 909-92 para. 4.2.5; VW Method: TL 909-92 para. 2.2.6; TL909-05 para.4.9; PV 3501; TL956:2001-06 para.5.2; TL956:2015 para 6.2; Ford Method: SDS 14451; FCA Method: PF-90078 para 5.8.2; PF-90165 para 5.8.2; MBN LV-124 Sec. K-10automotive components (including headlamps, rear and tail lamps)-
2ASTM B117-73; FMVSS 571.108; FCA Method: PF-90078; FCA Method: PF-90165; MBN LV-124; VW Method: TL 909-92; VW Method: TL909-05; SAE 575-70; SAE 575-88; SAE 575-92; SAE 575-04; GM Method: GMW14906; Ford Method: SDS EX-0011; SAE 575-92-04; Ford Method: SDS EX-0008; SAE J575-70; IP6K Acc DIN40050-9; SAE575-70; SAE575-88; SAE575-92; SAE575-04; Ford Method: SDS EX0226; MBN L-124; Ford Method: SDS 14455; GMN 3148-270 to 310 N
3FMVSS 571.108 S8.1 (10/2007); FMVSS 571.108 S14.2.5; FMVSS 571.108 S14.8.7; ECE Methods R1; ECE Methods R8; ECE Methods R19; ECE Methods R20; ECE Methods R87; ECE Methods R98; ECE Methods R99; ECE Methods R112; ECE Methods R123; GMN 3148 TP 4.3.12; GMN 3148 TP 4.3.13; SAE J575-70; SAE J575-80; SAE J575-92; SAE J575-04; SAE J583-93; SAE J852-65; SAE J1383-90; SAE J1735-95; SAE J2009-93; SAE J2087-91; FMVSS 571.108, S10.18; FMVSS 571.108 S14.2; FMVSS 571.108 S14.6.17.1; ECE Methods R1; ECE Methods R8; ECE Methods R19; ECE Methods R20; ECE Methods R87; ECE Methods R98; ECE Methods R99; ECE Methods R112; ECE Methods R123; FMVSS 571.108 S14.2; ECE Method: R3; ECE Method: R6; ECE Method: R7; ECE Method: R23; ECE Method: R38; ECE Method: R91; SAE J222-70; SAE J575-70; SAE J575-88; SAE J575-92; SAE J575-04; SAE J585-02; SAE J586-84; SAE J588-94; SAE J592-94; SAE J593 95; SAE J594-95; SAE J595-90; SAE J1319-93; SAE J1889-93; FMVSS 571.108 S.14.4.1; SAE J578-02; ECE Methods: R3; ECE Methods: R6; ECE Methods: R7; ECE Methods: R23; ECE Methods: R38; ECE Methods: R91Headlamps and Forward Lighting Devices; Rear Lighting, Signaling, Warning, Marking LED Devices, Cargo Lamps, and Reflex-
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the types of tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited MARELLI AUTOMOTIVE LIGHTING LLC – JUAREZ TEST LAB Ciudad Juarez, MEXICO for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 27th day of February 2025 _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2203.01 Valid to August 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

AVE. DEL CHARRO 1750 NORTE, COL. PARTIDO ESCOBEDO, CIUDAD JUAREZ, 32330, Mexico, CIUDAD JUAREZ, MX

31.73726, -106.48565

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.