Registers refreshed 2026-11-20.See refresh dates
Liechtenstein

Hilti Aktiengesellschaft Fastening Systems Research

Feldkircherstraße 100, Liechtenstein

DAKKS D-PL-11313-01-00ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
6
DAKKS certificate
1
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 6 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM E1190
EN 12390-1Testing hardened concrete - Part 1: Shape, dimensions and other requirements for specimens and moulds
EN 12390-2Testing hardened concrete - Part 2: Making and curing specimens for strength tests
EN 12390-3Testing hardened concrete - Part 3: Compressive strength of test specimens
EN 12390-7Testing hardened concrete - Part 7: Density of hardened concrete
EN 13791

Read from the scope as published by DAKKS. Register refreshed 2026-11-20.

Scope as published by DAKKS

3 lines
DAKKS

ISO/IEC 17025

Active

D-PL-11313-01-00

View scope

Accredited scope, certificate D-PL-11313-01-00

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001Concrete-
2ASTM E 1190; EAD 330232-01-0601; RFI DTC STS ENE SP IFS TE 673 A:2014Fasteners-
3DIN EN 13791 08-2019 Assessment of in -situ compressive strength in structures and precast concrete components DIN EN 12390 -1 12-2012 Testing hardened concrete - Part 1; DIN EN 12390 -2 10-2019 Testing hardened concrete - Part 2: Making and curing specimens for strength tests DIN EN 12390 -3 10-2019 Testing hardened concrete - Part 3: Compressive strength of test specimens DIN EN 12390 -7 10-2019 Testing hardened concrete - Part 7: Density of hardened concrete ZTV -ING Part 1 03-2015; EN 13791; EN 12390Concrete-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Labs with overlapping accredited scope in Liechtenstein

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.