International Super Sensors

2300 Reservoir St. Suite 306, 91766, Pomona, CA, United States

Visit website
A2LA 7067.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 7067.01 · 4 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7067.01) 09/08/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 INTERNATIONAL SUPER SENSORS CORP 2300 Reservoir St. Suite 306 Pomona, CA 91766 Eduardo Gallardo Phone: 909 590 5054 CALIBRATION Valid To: September 30, 2027 Certificate Number: 7067.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Thermocouples – Type B Type E Type J Type K Type N (1000 to 2000) °F (2000 to 2200) °F (2200 to 2642) °F (32 to 100) °F (100 to 1600) °F (32 to 100) °F (100 to 1400) °F (32 to 100) °F (100 to 2000) °F (2000 to 2200) °F (2200 to 2372) °F (32 to 100) °F (100 to 2000) °F (2000 to 2200) °F (2200 to 2372) °F 0.79 °F 1.2 °F 1.9 °F 0.34 °F 0.77 °F 0.35 °F 0.77 °F 0.35 °F 0.77 °F 1.2 °F 1.8 °F 0.34 °F 0.77 °F 1.2 °F 1.8 °F Martel 3001 NIST Type S Reference TC Type S Primary TC For temperature 32°F comparison to a NIST Traceable thermometer is performed For temperatures at or above 32° F, comparison to a Primary Type S thermocouple is performed
2AMS2750-32 to 2642 °F
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7067.01) 09/08/2025 Page 3 of 3 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited INTERNATIONAL SUPER SENSORS CORP Pomona, CA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of any additional program requirements in the calibration field. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 8th day of September 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7067.01 Valid to September 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2300 Reservoir St. Suite 306, Pomona, CA, 91766, US

34.05538, -117.75175

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.