INSTITUT QUIMIC DE SARRIA. CENTRE D`ENSENYAMENT TECNIC SUPERIOR, FUNDACIÓN PRIVADA (IQS)
Via Augusta, 390, 08017, Barcelona, Spain
- Accredited standards
- 5
- ENAC certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ENAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 5 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
EN 1948-2
EN 1948-3
EN 1948-4
EPA 1613
ISO 11338-2Stationary source emissions - Determination of gas and particle-phase polycyclic aromatic hydrocarbons - Part 2: Sample preparation, clean-up and determination
EPA 1613 B; UNE-EN 1948-2; UNE-EN 1948-3
UNE-EN 1948-4 + A1; UNE-ISO 11338-2; CEN/TS 1948-5; UNE-EN 1948-2; UNE-EN 1948-3
CEN/TS 1948-5; UNE-EN 1948-4 + A1; UNE-EN 1948-2; UNE-EN 1948-3
EPA 1613 B
Read from the scope as published by ENAC. Register refreshed 2026-10-10.
Scope as published by ENAC
8 lines
ISO/IEC 17025
Active196/LE344
Accredited scope, certificate 196/LE344
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNE-EN ISO/IEC 17025:2017 | Aguas de consumo; Aguas continentales; Aguas residuales (incluye lixiviados, aguas regeneradas y aguas depuradas); Aguas marinas; Suelos; Sedimentos; Cenizas; Biota (Vegetación); Soportes de muestreo de emisiones atmosféricas; Soportes de muestreo de aire ambiente | - |
| 2 | EPA 1613 B | Aguas de consumo; Aguas continentales; Aguas residuales (incluye lixiviados, aguas regeneradas y aguas depuradas) | 0.7 to pg/kg |
| 3 | EPA 1613 B | Aguas marinas; Suelos; Sedimentos | See scope document |
| 4 | EPA 1613 B; UNE-EN 1948-2; UNE-EN 1948-3 | Cenizas; Biota (Vegetación); Soportes de muestreo de emisiones atmosféricas | - |
| 5 | UNE-EN 1948-4 + A1; UNE-ISO 11338-2; CEN/TS 1948-5; UNE-EN 1948-2; UNE-EN 1948-3 | Soportes de muestreo de emisiones atmosféricas | - |
| 6 | CEN/TS 1948-5; UNE-EN 1948-4 + A1; UNE-EN 1948-2; UNE-EN 1948-3 | Soportes de muestreo de emisiones atmosféricas; Soportes de muestreo de aire ambiente | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active196/LE958
Accredited scope, certificate 196/LE958
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNE-EN ISO/IEC 17025:2017; IQS-MEDAM-PNT-A-0027; IQS-MEDAM-PNT-A-0026; IQS-MEDAM-PNT-A-0022; IQS-MEDAM-PNT-A-0024; IQS-MEDAM-PNT-A-0028; IQS-MEDAM-PNT-A-0029; IQS-MEDAM-PNT-A-0021; Reglamento (UE) 2017/644; Reglamento (CE) nº 152/2009 | Pescado y derivados; Carne y derivados; Huevos y derivados; Leche y derivados; Aceites, mantequilla y grasas; Piensos y premezclas; Aditivos minerales; Hierbas y forrajes | 0.06 to ng/g |
| 2 | IQS-MEDAM-PNT-A-0027; IQS-MEDAM-PNT-A-0026; IQS-MEDAM-PNT-A-0022; IQS-MEDAM-PNT-A-0024; IQS-MEDAM-PNT-A-0028; IQS-MEDAM-PNT-A-0029; IQS-MEDAM-PNT-A-0021; Reglamento (UE) 2017/644; Reglamento (CE) nº 152/2009 | Pescado y derivados; Carne y derivados; Huevos y derivados; Leche y derivados; Aceites, mantequilla y grasas; Piensos y premezclas; Aditivos minerales; Hierbas y forrajes | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the ENAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.