FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
United Kingdom

Theatre & Endoscopy Service Technicians Ltd trading as T.E.S.T.

Test House, Unit 8, Whieldon Industrial Estate, Stoke-on-Trent, ST4 4JP, Staffordshire, United Kingdom

UKAS|4522ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
3
Standards
5
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Theatre & Endoscopy Service Technicians Ltd trading as T.E.S.T.?

Claim this profile to keep it accurate.

Register record

UKASRefreshed
4522Active

Accredited standards

5

Our reading of the UKAS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ISO 11731Water quality - Enumeration of LegionellaCertificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 3 (UKAS 4522)

BS EN ISO 11731:2017; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 11731:2017; IEC 17025; SOP 118

ISO 15883-1Washer-disinfectors - Part 1: General requirements, terms and definitions and tests
As written on the certificate · Line 2 (UKAS 4522)

BS EN ISO 15883-1:2009; BS EN ISO15883-1:2009; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 15883-1:2009; ISO 23500-3:2019 2

ISO 15883-4Washer-disinfectors - Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes
As written on the certificate · Line 1 (UKAS 4522)

ISO/IEC 17025:2017; ISO 15883- 5:2009 Annex F Evaluation of Bacterial Contamination levels as a measure of Disinfection Efficacy SOP 107; ISO 15883-4:2018; IEC 17025; SOP 106

ISO 15883-5Washer-disinfectors - Part 5: Performance requirements and test method criteria for demonstrating cleaning efficacy
As written on the certificate · Line 1 (UKAS 4522)

ISO/IEC 17025:2017; ISO 15883- 5:2009 Annex F Evaluation of Bacterial Contamination levels as a measure of Disinfection Efficacy SOP 107; ISO 15883-4:2018; IEC 17025; SOP 106

ISO 23500-3Preparation and quality management of fluids for haemodialysis and related therapies - Part 3: Water for haemodialysis and related therapies
As written on the certificate · Line 2 (UKAS 4522)

BS EN ISO 15883-1:2009; BS EN ISO15883-1:2009; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 15883-1:2009; ISO 23500-3:2019 2

Scope as published by UKAS

3 lines
UKAS

ISO/IEC 17025

Active

4522

View scope

Accredited scope, certificate 4522

LineDisciplineMethodMatrixRange
1Biological TestingISO/IEC 17025:2017; ISO 15883- 5:2009 Annex F Evaluation of Bacterial Contamination levels as a measure of Disinfection Efficacy SOP 107; ISO 15883-4:2018; IEC 17025; SOP 106Steel-
2Biological TestingBS EN ISO 15883-1:2009; BS EN ISO15883-1:2009; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 15883-1:2009; ISO 23500-3:2019 2Drinking water-
3Biological TestingBS EN ISO 11731:2017; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 11731:2017; IEC 17025; SOP 118Drinking water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Test House, Unit 8, Whieldon Industrial Estate, Stoke-on-Trent, Staffordshire, ST4 4JP, GB

52.82469, -2.00745

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.