Intertek Testing Services NA

45000 Helm Street, Suite 150, 48170, Plymouth Township, MI, United States

A2LA|78.04A2LA|78.05ISO/IEC 17025Register collected 2026-08-22
Certificates
2
Scope items
8
Locations
9

Contact this laboratory

Watch this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Intertek Testing Services NA?

Claim this profile to keep it accurate.

Claim this profile

Register record

A2LACollected
78.04Active
78.05Active

Certificates and scope

2
A2LA

ISO/IEC 17025

Active

78.04

View scope

Accredited scope, certificate 78.04

DisciplineMethodMatrixRange
dimensionalSAE J575; JIS D0203; IEC 60529; DIN 40050; UL 1598; UL 50E; ISO 20653; VDA AK 1.4.2; ASTM D1204; SAE J1717; SAE J883; GM 7400M; PF 90010; UN 38.3; IEC 62133; UL 1642; UL 2054; MIL-STD-810; IEC 60601-1-1; IEC 60068-2-13Batteryto 12 ft
environmentalASTM B117; VDA AK 1.4.2; SAE J575; ISO 20653; IEC 60529; DIN 40050; JIS D0207; PF 90010; MIL-STD-810; USCAR-2; DC-10611; CS.00056; WDS-00.00EA-D11; GMW 3172; IEC 60068-2-28; IEC 60068-2-30; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14; IEC 60068-2-38; IEC 60068-2-78; UN 38.3; ISO 16750-4; TSM0502G; TSC 1000G; GMW 3431; IEC 60268-5; GMW 14011; GMW 7293; Ford CETP 01.01-L-407; CEPT 15.01-L-402; PF 13171Environmental Performance-65 to 28000 ºC; %RH; Hz; dBA
mechanical---
mechanicalMIL-STD-810, Methods 514 & 520; USCAR-2 Section 5.4.6; IEC 60068-2-6; IEC 60068-2-64; GMW 3172 Section 9.3.1; DC-10611 Section 6.2.1; CS.00054; WDS-00.00EA-D11 Section 4.6.1, FMVT; ABNT NBR 15940 Section 8.5.8; ABNT NBR 15941 Section 5.3.8; PF 90010, Section 9.5; VDA AK 1.4.2, Section 3.2.2; UN 38.3; SAE J1455; ISO 16750-3 Section 4.1; LV 124; VW80000; GS 9503; MIL-STD-810 Method 516; IEC 60068-2-27; GMW 3172 Section 9.3.3, 9.3.4 & 9.3.5; DC-10611 Section 6.2.2; CS.00056 Section 5.4.4; WDS-00.00EA-D11 Section 4.6.3; UN 38.3; ISO 16750-3 Section 4.2; ASTM B117; USCAR-1; SAE J2334; GMW14872; EN/IEC 60068-2-11; ISO 20653; PF 90010, Section 5.1; VDA AK 1.4.2, Section 3.4.2-50 to 55000 lbf

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

A2LA

ISO/IEC 17025

Active

78.05

View scope

Accredited scope, certificate 78.05

DisciplineMethodMatrixRange
dimensionalSAE J575; JIS D0203; IEC 60529; DIN 40050; UL 1598; UL 50E; ISO 20653; VDA AK 1.4.2; ASTM D1204; SAE J1717; SAE J883; GM 7400M; PF 90010; UN 38.3; IEC 62133; UL 1642; UL 2054; MIL-STD-810; IEC 60601-1-1; IEC 60068-2-13Batteryto 12 ft
environmentalASTM B117; VDA AK 1.4.2; SAE J575; ISO 20653; IEC 60529; DIN 40050; JIS D0207; PF 90010; MIL-STD-810; USCAR-2; DC-10611; CS.00056; WDS-00.00EA-D11; GMW 3172; IEC 60068-2-28; IEC 60068-2-30; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14; IEC 60068-2-38; IEC 60068-2-78; UN 38.3; ISO 16750-4; TSM0502G; TSC 1000G; GMW 3431; IEC 60268-5; GMW 14011; GMW 7293; Ford CETP 01.01-L-407; CEPT 15.01-L-402; PF 13171Environmental Performance-65 to 28000 ºC; %RH; Hz; dBA
mechanicalMIL-STD-810, Methods 514 & 520; USCAR-2 Section 5.4.6; IEC 60068-2-6; IEC 60068-2-64; GMW 3172 Section 9.3.1; DC-10611 Section 6.2.1; CS.00054; WDS-00.00EA-D11 Section 4.6.1, FMVT; ABNT NBR 15940 Section 8.5.8; ABNT NBR 15941 Section 5.3.8; PF 90010, Section 9.5; VDA AK 1.4.2, Section 3.2.2; UN 38.3; SAE J1455; ISO 16750-3 Section 4.1; LV 124; VW80000; GS 9503; MIL-STD-810 Method 516; IEC 60068-2-27; GMW 3172 Section 9.3.3, 9.3.4 & 9.3.5; DC-10611 Section 6.2.2; CS.00056 Section 5.4.4; WDS-00.00EA-D11 Section 4.6.3; UN 38.3; ISO 16750-3 Section 4.2; ASTM B117; USCAR-1; SAE J2334; GMW14872; EN/IEC 60068-2-11; ISO 20653; PF 90010, Section 5.1; VDA AK 1.4.2, Section 3.4.2-50 to 55000 lbf
mechanical---

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

Location

45000 Helm Street, Suite 150, Plymouth Township, MI, 48170, US