INSTITUT TECHNIQUE DES GAZ ET DE L'AIR - ITGA - SITE DE PARIS
16-18 rue Marcel Vigneron, 94110, ARCUEIL, France
Visit website- Accredited standards
- 9
- COFRAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 9 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.
FD X46-033
ISO 16000-4Indoor air - Part 4: Determination of formaldehyde - Diffusive sampling method
ISO 16000-7Indoor air - Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations
ISO 16017-1Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling
ISO 16017-2Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling
NF X43-269
NF X43-298
NF X46-032
NF X 43-050 (2021)
NF EN ISO 16000-7; FD X 46-033; NF X 43-050 (2021); NF X 43-269 (2017)
NF EN ISO 16000-7; FD X 46-033; NF X 43-050; NF X 46-032
NF EN ISO 16017-2; NF ISO 16000-4; Décret n° 2022-1690 du 27 décembre 2022 modifiant le décret n°2012-14 du 5 janvier 2012 relatif à l’évaluation des moyens d’aération et à la mesure des polluants effectuées au titre de la surveillance de la qualité de l’air intérieur de certains établissements recevant du public*
NF EN ISO 16017-1
Arrêté du 15 décembre 2009 relatif aux contrôles techniques des valeurs limites d’exposition professionnelle sur les lieux de travail et aux conditions d’accréditation des organismes chargés des contrôles *; NF X 43-298
Read from the COFRAC scope document we downloaded on 2026-09-25. Register refreshed 2026-11-20.
Scope as published by COFRAC
8 lines
ISO/IEC 17025
Active1-5969
The scope document we hold says it is valid until 2031-04-30.
Accredited scope, certificate 1-5969
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | NF EN ISO/IEC 17025 | AMIANTE - BATIMENT ET MATERIAUX - Qualité de l'Air; Air | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. Convention N° 6246
LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 2/8
Date de prise d’effet / Valid from : 01/05/2026
Date de fin de validité / Valid until : 30/04/2031
Pour le Directeur Général et par délégation
On behalf of the General Director
La Responsable du Pôle Air-Matériaux,
Pole manager - Air-Materials,
La présente attestation n’est valide qu’accompagnée de l’annexe technique.
This certificate is only valid if associated with the technical appendix.
L’accréditation peut être suspendue, modifiée ou retirée à tout moment. Pour une utilisation appropriée, la portée de
l’accréditation et sa validité doivent être vérifiées sur le site internet du Cofrac (www.cofrac.fr).
The accreditation can be suspended, modified or withdrawn at any time. For a proper use, the scope of accreditation and its
validity should be checked on the Cofrac website (www.cofrac.fr).
Cette attestation annule et remplace l’attestation N° 1-5969 Rév 22.
This certificate cancels and replaces the certificate N° 1-5969 Rév 22.
Seul le texte en français peut engager la responsabilité du Cofrac.
The Cofrac's liability applies only to the french text.
Comité Français d’Accréditation - 52, rue Jacques Hillairet 75012 PARIS
Tél. : +33 (0)1 44 68 82 20 – Fax : 33 (0)1 44 68 82 21 Siret : 397 879 487 00031 www.cofrac.fr | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 3/8
Section Laboratoires
ANNEXE TECHNIQUE
à l’attestation N° 1-5969 rév. 23
L’accréditation concerne les prestations réalisées par :
Institut Technique des Gaz et de l'Air - ITGA - Site de Paris
16-18 rue Marcel Vigneron
94110 ARCUEIL
Dans son unité :
- Prélèvement Paris
Elle porte sur : voir pages suivantes | ||
| 4 | NF EN ISO 16000-7; FD X 46-033; NF X 43-050 (2021); NF X 43-269 (2017) | Air intérieur; Air des lieux de travail | - |
| 5 | NF EN ISO 16000-7; FD X 46-033; NF X 43-050; NF X 46-032 | Air ambiant; Enveloppes du bâtiment, voirie et réseaux divers; Autres contextes, dont terrain naturel ou minier; Poussières au sol | - |
| 6 | NF EN ISO 16017-2; NF ISO 16000-4; Décret n° 2022-1690 du 27 décembre 2022 modifiant le décret n°2012-14 du 5 janvier 2012 relatif à l’évaluation des moyens d’aération et à la mesure des polluants effectuées au titre de la surveillance de la qualité de l’air intérieur de certains établissements recevant du public* | Air intérieur | - |
| 7 | Arrêté du 15 décembre 2009 relatif aux contrôles techniques des valeurs limites d’exposition professionnelle sur les lieux de travail et aux conditions d’accréditation des organismes chargés des contrôles *; NF X 43-298 | Air des lieux de travail | - |
| 8 | NF EN ISO 16017-1 | Air des lieux de travail | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in France
- BUREAU VERITAS EXPLOITATIONCOURBEVOIE · ~12 kmCOFRACShares 2 accredited test methodsEN ISO 16000-7EN ISO 16017-2
- INSTITUT TECHNIQUE DES GAZ ET DE L'AIR - ITGA - SITE DE LILLEVILLENEUVE D'ASCQ · ~210 kmCOFRACShares 2 accredited test methodsEN ISO 16000-7ISO 16017-1
- INSTITUT TECHNIQUE DES GAZ ET DE L'AIR - ITGA - SITE DE METZMETZ · ~285 kmCOFRACShares 2 accredited test methodsEN ISO 16000-7ISO 16017-1
- INSTITUT TECHNIQUE DES GAZ ET DE L'AIR - ITGA - SITE DE SAINT ETIENNESAINT ETIENNE · ~405 kmCOFRACShares 2 accredited test methodsEN ISO 16000-7EN ISO 16017-2
- INSTITUT TECHNIQUE DES GAZ ET DE L'AIR - ITGA - SITE DE MEYREUILMEYREUIL · ~639 kmCOFRACShares 2 accredited test methodsEN ISO 16000-7ISO 16017-1
Accreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.