China

TUV Rheinland (China)

Room 401, 4th Floor, Block C, Building 1, No. 139, Jinghai 3rd Road, Beijing Economic-Technological Development Area, Beijing, 100176, People's Republic of China, Beijing, China

A2LA 6386.01ISO/IEC 17025Register refreshed 2026-11-20
Part of the TÜV Rheinland group: 51 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
20
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 20 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60601 series13
IEC 60601-1-3
IEC 60601-1-6
IEC 60601-1-8
IEC 60601-2-2
IEC 60601-2-18
IEC 60601-2-22
IEC 60601-2-37
IEC 60601-2-43Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
IEC 60601-2-44Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography
IEC 60601-2-47
IEC 60601-2-52
IEC 60601-2-54Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy
IEC 60601-2-63
IEC4
IEC 60825-1
IEC 62304
IEC 62366-1
IEC 80601-2-77
IEC 61010 series3
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-081
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

6386.01

The scope document we hold says it was valid until 2026-07-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 6386.01

LineMethodMatrixRange
1GB 4793.1:2007; IEC 61010-1:2010 (ed. 3); EN 61010-1:2010 (ed. 3); IEC 61010-1 Edition 3.1 2017-01; GB 9706.1:2020; GB 9706.222-2022; GB 9706.237-2020; GB 9706.218-2021; GB 9706.202-2021; YY/T 0664-2020; IEC 61010-2-081:2019; EN IEC 61010-2-081:2020; IEC 61010-2-101:2018; EN 61010-2-101:2017; IEC 60601-1:2005+A1:2012+A2:2020; EN 60601-1:2006+A1:2013+A12:2014+A2:2021; IEC 62304:2006+A1:2015; EN 62304:2006+A1:2015; IEC 60601-2-22:2019; EN IEC 60601-2-22:2020; IEC 60601-2-52:2009+A1:2015; EN 60601-2-52:2010+AC:2011+A1:2015; IEC 60601-2-37:2007+A1:2015; EN 60601-2-37:2008+A11:2011+A1:2015; IEC 60601-2-18:2009; EN 60601-2-18:2015; IEC 60601-2-2:2017+A1:2023; EN IEC 60601-2-2:2018; IEC 60601-1-6 Edition 3.2 2020-07; EN 60601-1-6:2010+A1:2015+A2:2021; IEC 62366-1:2015+A1:2020; EN 62366-1:2015+A1:2020; ANSI AAMI ES60601-1:2005/(R)2012 & A1:2012, C1:2009/(R)2012 & A2:2010/(R)2012 (Cons. Text) [Incl. AMD2:2021]; GB 9706.103-2020; IEC 60601-1-3:2008+A1:2013+A2:2021; EN 60601-1-3:2008+A1:2013+A2:2021Electrical equipment-
2YY/T 9706.108-2021; IEC 60601-1-8:2006+A1:2012+A2:2020; EN 60601-1-8:2007+A1:2013+A11:2017+A2:2021; GB 9706.243-2021; IEC 60601-2-43:2010+A1:2017+A2:2019; EN 60601-2-43:2010+A1:2018+A2:2020; GB 9706.244-2020; IEC 60601-2-44:2009+A1:2012+A2:2016; EN 60601-2-44:2009+A1:2012+A2:2016; GB 9706.254-2020; IEC 60601-2-54:2009+A1:2015+A2:2018; EN 60601-2-54:2009+A1:2015+A2:2019; IEC 60601-2-54:2022; GB 9706.263-2020; IEC 60601-2-63:2012+A1:2017+A2:2021; EN 60601-2-63:2015+A1:2019+A2:2021; YY 9706.247-2021; IEC 60601-2-47:2012; EN 60601-2-47:2015; YY 9706.277-2023; IEC 80601-2-77:2019+A1:2023; EN IEC 80601-2-77:2021+A1:2023; IEC 60825-1:2014; EN 60825-1:2014+A11:2021; GB 4793.1:2007; IEC 61010-1:2010 (ed. 3); EN 61010-1:2010 (ed. 3); IEC 61010-2-081:2019; EN IEC 61010-2-081:2020; IEC 61010-2-101:2018; EN 61010-2-101:2017; IEC 61010-1 Ed 3.1 2017-01; GB 9706.222-2022; IEC 60601-2-22:2019; EN IEC 60601-2-22:2020; IEC 60601-2-52:2009+A1:2015; EN 60601-2-52:2010+AC:2011+A1:2015; GB 9706.1:2020; IEC 60601-1:2005+A1:2012+A2:2020; EN 60601-1:2006+A1:2013+A12:2014+A2:2021--
3ANSI AAMI ES60601-1:2005/(R)2012 & A1:2012, C1:2009/(R)2012 & A2:2010/(R)2012 (Cons. Text) [Incl. AMD2:2021]; GB 9706.237-2020; IEC 60601-2-37:2007+A1:2015; EN 60601-2-37:2008+A11:2011+A1:2015; GB 9706.202:2021; IEC 60601-2-2:2017+A1:2023; EN IEC 60601-2-2:2018; YY 9706.108-2021; IEC 60601-1-8:2006+A1:2012+A2:2020; EN 60601-1-8:2007+A1:2013+A11:2017+A2:2021; GB 9706.243-2021; IEC 60601-2-43:2010+A1:2017 +A2:2019; EN 60601-2-43:2010+A1:2018 +A2:2020; GB 9706.244-2020; IEC 60601-2-44:2009+A1:2012+A2:2016; EN 60601-2-44:2009+A1:2012+A2:2016; GB 9706.254-2020; IEC 60601-2-54:2022; IEC 60601-2-54:2009+A1:2015+A2:2018; EN 60601-2-54:2009+A1:2015+A2:2019; YY 9706.247-2021; IEC 60601-2-47:2012; EN 60601-2-47:2015; IEC 60825-1:2014; EN 60825-1:2014+A11:2021--
4ANSI AAMI ES60601-1:2005/(R)2012 & A1:2012, C1:2009/(R)2012 & A2:2010/(R)2012; IEC 60601-1 Edition 3.2 2020-08; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-18: Edition 3.0 2009-08; IEC 60601-2-22 Edition 4.0 2019-11; IEC 60601-2-37 Edition 2.1 2015; IEC 60601-2-52 Edition 1.1 2015-03; IEC 61010-1 Edition 3.1 2017-01; IEC 60601-1-3 Edition 2.2 2021-01; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-2-43 Edition 2.2 2019-10; IEC 60601-2-44 Edition 3.2: 2016; IEC 60601-2-54 Edition 2.0 2022-09; IEC 60601-2-63 Edition 1.2 2021-05; IEC 60601-2-47 Edition 2.0 2012-02; IEC 80601-2-77 Edition 1.0 2019-07Medical Electrical Equipment; Medical Electrical Systems; Laboratory Medical Equipment-
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited TÜV RHEINLAND (CHINA) LTD. Beijing, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets A2LA R256 - Specific Requirements - FDA ASCA Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 3rd day of October 2024. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6386.01 Valid to July 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.