Registers refreshed 2026-11-15.See refresh dates
Germany

Lynxeo Deutschland

Sieboldstraße 10, 90411, Nürnberg, Germany

DAKKS D-PL-22266-01-01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
23
DAKKS certificate
1
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 23 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60332 series8
IEC 60332-1-1
IEC 60332-1-2Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
IEC 60332-1-3
IEC 60332-3-21
IEC 60332-3-22
IEC 60332-3-23
IEC 60332-3-24
IEC 60332-3-25
IEC5
IEC 60684-2
IEC 60754-1
IEC 60754-2
IEC 61034-1
IEC 61034-2
IEC 60331 series5
IEC 60331-1
IEC 60331-2
IEC 60331-11
IEC 60331-21
IEC 60331-23
ISO3
ISO 6722-1Road vehicles - 60 V and 600 V single-core cables - Part 1: Dimensions, test methods and requirements for copper conductor cables
ISO 6722-2Road vehicles - 60 V and 600 V single-core cables - Part 2: Dimensions, test methods and requirements for aluminium conductor cables
ISO 14572Road vehicles - Round, sheathed, 60 V and 600 V screened and unscreened single- or multi-core cables - Test methods and requirements for basic- and high-performance cables
Other standards2
EN 50200
EN 50305

Read from the scope as published by DAKKS. Register refreshed 2026-11-06.

Scope as published by DAKKS

8 lines
DAKKS

ISO/IEC 17025

Active

D-PL-22266-01-01

View scope

Accredited scope, certificate D-PL-22266-01-01

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018Kabeln und Leitungen-
2Def Stan 02-713 - Issue 03; DIN EN 50305 (VDE 260-305):2021-01; DIN EN 60754 -1 (VDE 0482-754-1):2021-02; IEC 60754 -1 (2011 -11) + IEC 60754-1 (2013-11) Ed. 3.0 - Corrigendum 1 + AMD1:2019; DIN EN 60754 -2 (VDE 0482-754-2):2021-02 + Berichtigung 1 2022-08; IEC 60754 -2 (2011 -11) + AMD1:2019Products of Combustion from Small Specimens of Materials; Kabel und Leitungen für Schienenfahrzeuge; Werkstoffe von Kabeln und isolierten Leitungen; electric cables-
3DIN VDE 0472 -815 (VDE 0472-815):1989-03; DIN EN 60684 -2 (VDE 0341-2):2012-05; IEC 60684 -2 (2011 -08); DIN EN 50305 (VDE 260-305):2021-01; DIN EN 50200 (VDE 0482-200):2016-07; DIN EN IEC 60331 -1 (VDE 0482-331-1):2020-08; IEC 60331-1 (2018-03)electric cables; Flexible insulating sleeving; cables and insulated wires-
4IEC 60331-2 (2018-03); IEC 60331-11 (2009-07); IEC 60331-21 (1999-04); IEC 60331-23 (1999-04); DIN EN 60332-1-1 (VDE 0482-332-1-1):2017-09; DIN EN 60332-1-2 (VDE 0482-332-1-2):2022-07; DIN EN 60332-1-3 (VDE 0482-332-1-3):2017-09electric cables; insulated wires; optical fiber cables-
5IEC 60332-1-1 (2004 -07) + AMD1: 2015-07; IEC 60332-1-2 (2004 -07) + AMD1: 2015-07; IEC 60332-1-3 (2004 -07) + AMD1: 2015-07; DIN EN 60332-3-21 (VDE 0482-332-3-21):2019-05; DIN EN 60332-3-22 (VDE 0482-332-3-22):2019-05; DIN EN 60332-3-23 (VDE 0482-332-3-23):2019-05electric and optical fibre cables-
6DIN EN 60332-3-24; DIN EN 60332-3-25; IEC 60332-3-21; IEC 60332-3-22; IEC 60332-3-23; IEC 60332-3-24; IEC 60332-3-25Kabeln, isolierten Leitungen und Glasfaserkabeln-
7DIN VDE 0276 -604; VDE 0276-604:2008-02; DIN EN 61034 -1 (VDE 0482-1034-1):2021-02; DIN EN 61034 -2 (VDE 0482-1034-2):2021-02; IEC 61034 -1 (2013 -06) +AMD2:2019-11; IEC 61034 -2 (2013 -06) +AMD2:2019-11; ISO 6722 -1 Technical Corrigendum 1:2012-09; ISO 6722 -2:2013 -12; ISO 14572:2011 -10Starkstromkabel; Kabel und isolierte Leitungen; Road vehicles - single-core cables; Road vehicles - screened and unscreened single- or multi-core cables-
8DIN; EN; IEC; ISO--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Sieboldstraße 10, Nürnberg, 90411, DE

49.47936, 11.12233

Open in Maps

Accreditation data refreshed from the DAKKS register on .