FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Australia

Vipac Engineers & Scientists

279 Normanby Road, Port Melbourne, Victoria , 3207, Australia, Port Melbourne, Victoria, Australia

A2LA|5677.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
5
Standards
17
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Vipac Engineers & Scientists?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
5677.01Active

Accredited standards

17

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 60068 series

IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
As written on the certificate · Line 1 (A2LA 5677.01)

AS/IEC/EN 60068-2-1; AS/IEC/EN 60068-2-2; AS/IEC/EN 60068-2-30; AS/IEC/EN 60068-2-78; AS/IEC/EN 60068-2-14; IEC/EN 50155; BS EN50125-3; MIL-STD-810 E; MIL-STD-810 F

IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
As written on the certificate · Line 1 (A2LA 5677.01)

AS/IEC/EN 60068-2-1; AS/IEC/EN 60068-2-2; AS/IEC/EN 60068-2-30; AS/IEC/EN 60068-2-78; AS/IEC/EN 60068-2-14; IEC/EN 50155; BS EN50125-3; MIL-STD-810 E; MIL-STD-810 F

IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
As written on the certificate · Line 2 (A2LA 5677.01)

MIL-STD-810 G; MIL-STD-810 H; DEF STAN 00-035; ISTA 2A; ISTA 2B; ISTA 3A; ISTA 3B; ASTM D4169; AS/IEC/EN 60068-2-11; AS/IEC/EN 60068-2-52; ASTM D6653; AS/IEC/EN 60068-2-13

IEC 60068-2-13Name not checked yet
As written on the certificate · Line 2 (A2LA 5677.01)

MIL-STD-810 G; MIL-STD-810 H; DEF STAN 00-035; ISTA 2A; ISTA 2B; ISTA 3A; ISTA 3B; ASTM D4169; AS/IEC/EN 60068-2-11; AS/IEC/EN 60068-2-52; ASTM D6653; AS/IEC/EN 60068-2-13

IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
As written on the certificate · Line 1 (A2LA 5677.01)

AS/IEC/EN 60068-2-1; AS/IEC/EN 60068-2-2; AS/IEC/EN 60068-2-30; AS/IEC/EN 60068-2-78; AS/IEC/EN 60068-2-14; IEC/EN 50155; BS EN50125-3; MIL-STD-810 E; MIL-STD-810 F

IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
As written on the certificate · Line 1 (A2LA 5677.01)

AS/IEC/EN 60068-2-1; AS/IEC/EN 60068-2-2; AS/IEC/EN 60068-2-30; AS/IEC/EN 60068-2-78; AS/IEC/EN 60068-2-14; IEC/EN 50155; BS EN50125-3; MIL-STD-810 E; MIL-STD-810 F

IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
As written on the certificate · Line 2 (A2LA 5677.01)

MIL-STD-810 G; MIL-STD-810 H; DEF STAN 00-035; ISTA 2A; ISTA 2B; ISTA 3A; ISTA 3B; ASTM D4169; AS/IEC/EN 60068-2-11; AS/IEC/EN 60068-2-52; ASTM D6653; AS/IEC/EN 60068-2-13

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
As written on the certificate · Line 1 (A2LA 5677.01)

AS/IEC/EN 60068-2-1; AS/IEC/EN 60068-2-2; AS/IEC/EN 60068-2-30; AS/IEC/EN 60068-2-78; AS/IEC/EN 60068-2-14; IEC/EN 50155; BS EN50125-3; MIL-STD-810 E; MIL-STD-810 F

ASTM

ASTM D999Name not checked yet
As written on the certificate · Line 4 (A2LA 5677.01)

BS EN 50125-3; IEC/EN 50155; IEC 61373; ASTM D4169; ASTM D5276; ASTM D4728; ASTM D999; ASTM D6344

ASTM D4169Name not checked yet
As written on the certificate · Line 2 (A2LA 5677.01)

MIL-STD-810 G; MIL-STD-810 H; DEF STAN 00-035; ISTA 2A; ISTA 2B; ISTA 3A; ISTA 3B; ASTM D4169; AS/IEC/EN 60068-2-11; AS/IEC/EN 60068-2-52; ASTM D6653; AS/IEC/EN 60068-2-13

As written on the certificate · Line 4 (A2LA 5677.01)

BS EN 50125-3; IEC/EN 50155; IEC 61373; ASTM D4169; ASTM D5276; ASTM D4728; ASTM D999; ASTM D6344

ASTM D4728Name not checked yet
As written on the certificate · Line 4 (A2LA 5677.01)

BS EN 50125-3; IEC/EN 50155; IEC 61373; ASTM D4169; ASTM D5276; ASTM D4728; ASTM D999; ASTM D6344

ASTM D5276Name not checked yet
As written on the certificate · Line 4 (A2LA 5677.01)

BS EN 50125-3; IEC/EN 50155; IEC 61373; ASTM D4169; ASTM D5276; ASTM D4728; ASTM D999; ASTM D6344

ASTM D6344Name not checked yet
As written on the certificate · Line 4 (A2LA 5677.01)

BS EN 50125-3; IEC/EN 50155; IEC 61373; ASTM D4169; ASTM D5276; ASTM D4728; ASTM D999; ASTM D6344

ASTM D6653Name not checked yet
As written on the certificate · Line 2 (A2LA 5677.01)

MIL-STD-810 G; MIL-STD-810 H; DEF STAN 00-035; ISTA 2A; ISTA 2B; ISTA 3A; ISTA 3B; ASTM D4169; AS/IEC/EN 60068-2-11; AS/IEC/EN 60068-2-52; ASTM D6653; AS/IEC/EN 60068-2-13

Other standards

EN 50125-3Name not checked yet
As written on the certificate · Line 4 (A2LA 5677.01)

BS EN 50125-3; IEC/EN 50155; IEC 61373; ASTM D4169; ASTM D5276; ASTM D4728; ASTM D999; ASTM D6344

EN 50155Railway applications - Rolling stock - Electronic equipment
As written on the certificate · Line 1 (A2LA 5677.01)

AS/IEC/EN 60068-2-1; AS/IEC/EN 60068-2-2; AS/IEC/EN 60068-2-30; AS/IEC/EN 60068-2-78; AS/IEC/EN 60068-2-14; IEC/EN 50155; BS EN50125-3; MIL-STD-810 E; MIL-STD-810 F

As written on the certificate · Line 4 (A2LA 5677.01)

BS EN 50125-3; IEC/EN 50155; IEC 61373; ASTM D4169; ASTM D5276; ASTM D4728; ASTM D999; ASTM D6344

IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
As written on the certificate · Line 4 (A2LA 5677.01)

BS EN 50125-3; IEC/EN 50155; IEC 61373; ASTM D4169; ASTM D5276; ASTM D4728; ASTM D999; ASTM D6344

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

5677.01

The scope document we hold says it is valid until 2026-12-31.

View scope

Accredited scope, certificate 5677.01

LineDisciplineMethodMatrixRange
1mechanicalAS/IEC/EN 60068-2-1; AS/IEC/EN 60068-2-2; AS/IEC/EN 60068-2-30; AS/IEC/EN 60068-2-78; AS/IEC/EN 60068-2-14; IEC/EN 50155; BS EN50125-3; MIL-STD-810 E; MIL-STD-810 FAerospace, Automotive, Consumer Goods, Communication, Defence, Electrical, Electronics, Infrastructure, Medical, Railway, Renewable Energy, Heavy Industrial and Manufactured products-70 to 180 °C
2environmentalMIL-STD-810 G; MIL-STD-810 H; DEF STAN 00-035; ISTA 2A; ISTA 2B; ISTA 3A; ISTA 3B; ASTM D4169; AS/IEC/EN 60068-2-11; AS/IEC/EN 60068-2-52; ASTM D6653; AS/IEC/EN 60068-2-13--70 to 180 °C
3mechanicalIEC/EN/AS 60068-2-6; IEC/EN/AS 60068-2-27; IEC/EN/AS 60068-2-29; IEC/EN/AS 60068-2-32; IEC/EN/AS 60068-2-64; IEC/EN/AS 60068-2-31; MIL-STD-810E; MIL-STD-810F; MIL-STD-810G; MIL-STD-810H; MIL-STD-167-1A; ISTA 2A; ISTA 2B; ISTA 3A; ISTA 3B; DEF-STAN-0035-1 to 2000 Hz
4mechanicalBS EN 50125-3; IEC/EN 50155; IEC 61373; ASTM D4169; ASTM D5276; ASTM D4728; ASTM D999; ASTM D6344-1 to 2000 Hz
5mechanical
For the types of tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited VIPAC ENGINEERS & SCIENTISTS LTD. Port Melbourne, Victoria, Australia for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 14th day of March 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 5677.01 Valid to December 31, 2026

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

279 Normanby Road, Port Melbourne, Victoria , 3207, Australia, Port Melbourne, Victoria, AU

-37.83336, 144.92192

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.