Vipac Engineers & Scientists
279 Normanby Road, Port Melbourne, Victoria , 3207, Australia, Port Melbourne, Victoria, Australia
Visit website- Accredited standards
- 17
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 17 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068 series8
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-13
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ASTM6
ASTM D999
ASTM D4169
ASTM D4728
ASTM D5276
ASTM D6344
ASTM D6653
Other standards3
EN 50125-3
EN 50155Railway applications - Rolling stock - Electronic equipmentSome clauses
Limits written next to it
IEC/EN 50155: clause 13.4.11
IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
AS/IEC/EN 60068-2-1; AS/IEC/EN 60068-2-2; AS/IEC/EN 60068-2-30; AS/IEC/EN 60068-2-78; AS/IEC/EN 60068-2-14; IEC/EN 50155; BS EN50125-3; MIL-STD-810 E; MIL-STD-810 F
MIL-STD-810 G; MIL-STD-810 H; DEF STAN 00-035; ISTA 2A; ISTA 2B; ISTA 3A; ISTA 3B; ASTM D4169; AS/IEC/EN 60068-2-11; AS/IEC/EN 60068-2-52; ASTM D6653; AS/IEC/EN 60068-2-13
BS EN 50125-3; IEC/EN 50155; IEC 61373; ASTM D4169; ASTM D5276; ASTM D4728; ASTM D999; ASTM D6344
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active5677.01
The scope document we hold says it is valid until 2026-12-31.
Accredited scope, certificate 5677.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | AS/IEC/EN 60068-2-1; AS/IEC/EN 60068-2-2; AS/IEC/EN 60068-2-30; AS/IEC/EN 60068-2-78; AS/IEC/EN 60068-2-14; IEC/EN 50155; BS EN50125-3; MIL-STD-810 E; MIL-STD-810 F | Aerospace, Automotive, Consumer Goods, Communication, Defence, Electrical, Electronics, Infrastructure, Medical, Railway, Renewable Energy, Heavy Industrial and Manufactured products | -70 to 180 °C |
| 2 | MIL-STD-810 G; MIL-STD-810 H; DEF STAN 00-035; ISTA 2A; ISTA 2B; ISTA 3A; ISTA 3B; ASTM D4169; AS/IEC/EN 60068-2-11; AS/IEC/EN 60068-2-52; ASTM D6653; AS/IEC/EN 60068-2-13 | - | -70 to 180 °C |
| 3 | IEC/EN/AS 60068-2-6; IEC/EN/AS 60068-2-27; IEC/EN/AS 60068-2-29; IEC/EN/AS 60068-2-32; IEC/EN/AS 60068-2-64; IEC/EN/AS 60068-2-31; MIL-STD-810E; MIL-STD-810F; MIL-STD-810G; MIL-STD-810H; MIL-STD-167-1A; ISTA 2A; ISTA 2B; ISTA 3A; ISTA 3B; DEF-STAN-0035 | - | 1 to 2000 Hz |
| 4 | BS EN 50125-3; IEC/EN 50155; IEC 61373; ASTM D4169; ASTM D5276; ASTM D4728; ASTM D999; ASTM D6344 | - | 1 to 2000 Hz |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. For the types of tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
VIPAC ENGINEERS & SCIENTISTS LTD.
Port Melbourne, Victoria, Australia
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 14th day of March 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 5677.01
Valid to December 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
279 Normanby Road, Port Melbourne, Victoria , 3207, Australia, Port Melbourne, Victoria, AU
-37.83336, 144.92192
Open in MapsAccreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.