Furnace Rebuilders
915 Dove Court, 28037, Denver, NC, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 4107.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4107.01) 01/07/2025 Page 1 of 4
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
FURNACE REBUILDERS INCORPORTAED
915 Dove Court
Denver, NC 28037
Matthew Messer Phone: 704 483 4025
CALIBRATION
Valid To: February 28, 2027 Certificate Number: 4107.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 4:
I. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
DC Voltage – Measure3
(-13 to 80) mV
(0.0 to 100) mV
(0.1 to 10) V
(-10 to 75 000) mV
(0.0 to 10.0000) V
0.12 mV
0.18 mV
0.12 V
0.8 mV
0.16 mV
PIECAL 322
thermocouple calibrator
with NIST traceable cold
junction thermistor
PIECAL 235 voltage
analyzer
Fluke 7526A precision
calibrator | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4107.01) 01/07/2025 Page 2 of 4
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
DC Voltage – Generate3
(-13 to 80) mV
(-10 to 75 000) mV
(0.0 to 10.0000) V
0.14 mV
0.13 mV
0.8 mV
0.16 mV
PIECAL 322
thermocouple calibrator
with NIST traceable cold
junction thermistor
PIECAL 235 voltage
analyzer
Fluke 7526A precision
calibrator
Electrical Calibration of
mV Thermocouple
Sources– Measure and
Generate
Type J
Type K
Type T
Type E
Type R
Type S
Type B
(-200 to 500) °C
(500 to 1200) °C
(-200 to 1050) °C
(1050 to 1371) °C
(-200 to 0.0) °C
(0.0 to 400) °C
(-200 to 850) °C
(850 to 1000) °C
(0.0 to 500) °C
(500 to 1750) °C
(0.0 to 500) °C
(500 to 1750) °C
(800 to 1000) °C
(1000 to 1800) °C
0.92 °C
0.73 °C
1.5 °C
1.2 °C
1.70 °C
0.50 °C
1.2 °C
0.70 °C
4.2 °C
3.5 °C
4.2 °C
3.6 °C
4.1 °C
3.5 °C
PIECAL 322
thermocouple calibrator
with NIST traceable cold
junction thermistor
PIECAL 322
thermocouple calibrator
with NIST traceable cold
junction thermistor
PIECAL 322
thermocouple calibrator
with NIST traceable cold
junction thermistor
PIECAL 322
thermocouple calibrator
with NIST traceable cold
junction thermistor
Fluke 725 multifunction
temperature calibrator
Fluke 725 multifunction
temperature calibrator
Fluke 725 multifunction
temperature calibrator | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4107.01) 01/07/2025 Page 3 of 4
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
mV Thermocouple
Sources– Measure and
Generate (cont)
Type N
Type B
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(0.0 to 400) °C
(600 to 800) °C
(800 to 1550) °C
(0.0 to 600) °C
(600 to 1000) °C
(-100 to 800) °C
(800 to 1200) °C
(-100 to 500) °C
(800 to 1372) °C
(-100 to 800) °C
(800 to 1300) °C
(0 to 1600) °C
(1600 to 1767) °C
(0 to 1600) °C
(1600 to 1767) °C
(-100.0 to 200) °C
(200 to 400) °C
3.5 °C
1.2 °C
0.86 °C
0.39 °C
0.53 °C
0.66 °C
0.57 °C
0.83 °C
0.91 °C
0.99 °C
0.66 °C
1.50 °C
0.99 °C
1.40 °C
1.1 °C
0.59 °C
0.41 °C
Fluke 725 multifunction
temperature calibrator
Fluke 7526A precision
calibrator
Fluke 7526A precision
calibrator
Fluke 7526A precision
calibrator
Fluke 7526A precision
calibrator
Fluke 7526A precision
calibrator
Fluke 7526A precision
calibrator
Fluke 7526A precision
calibrator
Fluke 7526A precision
calibrator | ||
| 4 | AMS 2750 | - | 0 to 1370 °C |
| 5 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.