Institut für Umwelt- und Arbeitsplatzanalytik Burkon

Raudtener Straße 19/19 b, 90475, Nürnberg, Germany

Visit website
DAKKS D-PL-18586-01-00ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
18
DAKKS certificate
1
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 18 standard numbers and the 15 official names we hold. When no standard matches, it searches the method text of every scope line.

EN16
EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
EN 1948-1Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 13284-2
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
EN 14212
EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 14884
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
EN 15259Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
Other standards2
ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
ISO 16911-2Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 2: Automated measuring systems

Read from the scope as published by DAKKS. Register refreshed 2026-11-20.

Scope as published by DAKKS

7 lines
DAKKS

ISO/IEC 17025

Active

D-PL-18586-01-00

View scope

Accredited scope, certificate D-PL-18586-01-00

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--
2DIN EN ISO 16911-1 : 2013-06 DIN EN ISO 16911-2 : 2013-06 Kennung P Partikelförmige und an Partikeln adsorbierte chemische Stoffe Gesamtstaub bei geringen Staubkonzentrationen DIN EN 13284-1:2018-02; DIN EN 15259:2008; DIN EN 14790:2017-05 Sauerstoff DIN EN 14789:2017-05 Temperatur VDI/VDE 3511 Blatt 1 : 1996-03 Volumenstrom DIN EN ISO 16911-1 : 2013-06 DIN EN ISO 16911-2 : 2013-06 Kennung P Partikelförmige und an Partikeln adsorbierte chemische Stoffe Gesamtstaub bei geringen Staubkonzentrationen DIN EN 13284-1:2018-02; DIN EN 14385:2004-05; DIN EN 13211:2001-06 BaP VDI 3874 : 2006-12Air-
3DIN EN 14385 : 2004-05; DIN EN 14792:2017-05 CO DIN EN 15058:2017-05 SO2 DIN EN 14791:2017-05 HCl DIN EN 1911:2010-12 HF VDI 2470 Blatt 1 : 1975-10 DIN CEN/TS 17340 : 2021-01; DIN EN 12619:2013-04 Aldehyde/Ketone VDI 3862 Blatt 2 : 2000-12; VDI 2066 Blatt 1 : 2021-05; VDI 3868 Blatt 1 : 1994-12Metal-
4DIN EN ISO 16911-1:2013-06 DIN EN ISO 16911-2:2013-06 Volumenstrom DIN EN ISO 16911-1:2013-06 DIN EN ISO 16911-2:2013-06 Sauerstoff DIN EN 14789:2017-05; DIN EN 14212 : 2022-11 Eignungsgeprüfter Analysator: NGA 2000 MLT 3; DIN EN 1948-1:2006-06 faserförmiger Stoffe VDI 3861 Blatt 2: 2023-05; ISO 16911-1:2013-06 DIN EN ISO 16911-2:2013-06 Volumenstrom DIN EN ISO 16911-1:2013-06 DIN EN ISO 16911-2:2013-06 Sauerstoff DIN EN 14789:2017-05; VDI 2462 Blatt 4 : 1975-08 Eignungsgeprüfter Analysator: PG-350Air-
5DIN EN 14790:2017-05 Prüfung der Funktionstüchtigkeit DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Prüfung der Dichtheit DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Prüfung der Gerätekennlinie DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04; DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Bescheinigung des ordnungsgemäßen Einbaus DIN EN 14181:2015-02 VDI 3950 Blatt 1:2018-06 Ermittlung der Querempfindlichkeit DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Ermittlung der Einstellzeit DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Ermittlung der Null- und Referenzpunktdrift DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Ermittlung der Kalibrierfunktion DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Zusätzliche Komponenten im Rahmen der Ermittlung von Emissionen: Staub automatische Messeinrichtungen DIN EN 13284-2:2018-02; VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Prüfung der Dichtheit DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Prüfung der Gerätekennlinie DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04; VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Bescheinigung des ordnungsgemäßen Einbaus DIN EN 14181:2015-02 VDI 3950 Blatt 1:2018-06 Ermittlung der Querempfindlichkeit DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Ermittlung der Einstellzeit DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Ermittlung der Null- und Referenzpunktdrift DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Ermittlung der Kalibrierfunktion DIN EN 14181: 2015-02 VDI 3950 Blatt 1: 2018-06 VDI 3950 Blatt 2: 2020-04 Zusätzliche Komponenten im Rahmen der Ermittlung von Emissionen: Staub automatische Messeinrichtungen DIN EN 13284-2:2018-02; EN 14790--
6DIN EN 14884 : 2023-02; EN 14884--
7IFA 6068:2015-05; IFA 7284:2003-10; IFA 6310: 2016-05/ 2016-10; IFA 7755: 2003-10; IFA 7808: 2021-11; DGUV 213-505: 2022-03Metal-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Raudtener Straße 19/19 b, Nürnberg, 90475, DE

49.41333, 11.16320

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.