Northburn Oils
NOL Testing Laboratory, 70 Northburn Road, Coatbridge, ML5 2HY, Scotland, United Kingdom
- Accredited standards
- 8
- UKAS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the UKAS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM D2622
BS 2000-375
BS 2000-398
BS 2000-523
ISO 3170Hydrocarbon Liquids - Manual sampling
ISO 3679Determination of flash point - Method for flash no-flash and flash point by small scale closed cup tester
ISO 10307-1Petroleum products - Total sediment in residual fuel oils - Part 1: Determination by hot filtration
ISO 10370Petroleum products - Determination of carbon residue - Micro method
BS EN ISO 10370:14 Micro method Flashpoint IP 523/23 BS 2000-523:23 BS EN ISO 3679:22 Rapid equilibrium closed cup Total Sediment IP 375/11 BS 2000-375:11 ISO 10307-1:09; BS EN ISO 3170:04 Sulphur content ASTM D2622-21 using in house method LABWIN09; BS 2000-398; BS 2000-523; BS 2000-375
Read from the scope as published by UKAS. Register refreshed 2026-11-20.
Scope as published by UKAS
2 lines
ISO/IEC 17025
Active7830
Accredited scope, certificate 7830
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | BS EN ISO 10370:14 Micro method Flashpoint IP 523/23 BS 2000-523:23 BS EN ISO 3679:22 Rapid equilibrium closed cup Total Sediment IP 375/11 BS 2000-375:11 ISO 10307-1:09; BS EN ISO 3170:04 Sulphur content ASTM D2622-21 using in house method LABWIN09; BS 2000-398; BS 2000-523; BS 2000-375 | Water; Oils; OIL | - |
| 2 | ISO/IEC 17025:2017; IP 593/11; IP 608/15; IP 503/04 | Metal | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
NOL Testing Laboratory, 70 Northburn Road, Coatbridge, Scotland, ML5 2HY, GB
55.87197, -4.01381
Open in MapsLabs with overlapping accredited scope in United Kingdom
- Evolution Fasteners (UK)Glasgow · ~13 kmUKASShares 1 accredited materialMetal
- TUV SUD Limited Trading as TÜV SÜD National Engineering Laboratory & National EngineeringGlasgow · ~16 kmUKASShares 1 accredited materialMetal
- Impact Laboratories Limited Trading as Impact SolutionsLivingston · ~31 kmUKASShares 1 accredited materialMetal
- IOM ConsultingPenicuik · ~50 kmUKASShares 1 accredited materialMetal
- The Edinburgh Assay OfficeEdinburgh · ~52 kmUKASShares 1 accredited materialMetal
Accreditation data refreshed from the UKAS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.