Registers refreshed 2026-11-20.See refresh dates
Canada

Celltech Labs Inc.

21-364 Lougheed Road, Kelowna, British Columbia V1X 7R8, BC V1X7R8, Canada, Kelowna, British Columbia V1X 7R8, Canada

Visit website
A2LA 2470.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
9
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 9 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.

ANSI C63
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environmentsExclusion

Limits written next to it

EN 61000-6-1 (excluding the following measurement:

Exclusion. Written next to it on line 2 of A2LA certificate 2470.01.

IEC 61000-6-1 (excluding the following measurement:

Exclusion. Written next to it on line 2 of A2LA certificate 2470.01.

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environmentsExclusion

Limits written next to it

EN 61000-6-2 (excluding the following measurements:

Exclusion. Written next to it on line 2 of A2LA certificate 2470.01.

IEC 61000-6-2 (excluding the following measurements:

Exclusion. Written next to it on line 2 of A2LA certificate 2470.01.

IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsExclusion

Limits written next to it

EN 61000-6-3 (excluding the following measurements:

Exclusion. Written next to it on line 1 of A2LA certificate 2470.01.

IEC 61000-6-3 (excluding the following measurements:

Exclusion. Written next to it on line 1 of A2LA certificate 2470.01.

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 62209-1
IEC 62209-2

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

2470.01

The scope document we hold says it is valid until 2026-11-30.

View scope

Accredited scope, certificate 2470.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-6-3-See scope document
2IEC 61000-6-4; IEC 61000-6-1; IEC 61000-6-2; ANSI C63; ANSI/TIA-603-to 40 GHz
3IEC 62209-1; IEC 62209-2; IEEE 1528; IEEE 62209-1528; ANSI C63-See scope document
4IEEE 62209-1528; ANSI C63; ANSI/TIA-603-to 40000 MHz
5ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

21-364 Lougheed Road, Kelowna, British Columbia V1X 7R8, BC V1X7R8, Canada, Kelowna, British Columbia V1X 7R8, CA

49.88792, -119.49590

Open in Maps

Labs with overlapping accredited scope in Canada

Accreditation data refreshed from the A2LA register on .