Registers refreshed 2026-11-20.See refresh dates
United States

RG Loewenguth Co

2144 Brighton-Henrietta TL Road, 14623, Rochester, NY, United States

Visit website
A2LA 7046.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 7046.01 · 3 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7046.01) 8/05/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO 17025:2017 RG LOEWENGUTH CO, INC. 2144 Brighton-Henrietta TL Road Rochester, NY 14623 Kevin Christensen Phone: 585 694 6800 CALIBRATION Valid To: June 30, 2027 Certificate Number: 7046.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1,5: I. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Video Measurement Systems3 – XY Length Z Length Up to 8 in (8 to 12) in (12 to 18) in (18 to 24) in Up to 4 in (38 + 0.9L + 0.6R) µin (36 + 1.2L + 0.6R) µin (53 + 2.3L + 0.6R) µin (55 + 1.8L + 0.6R) µin (30 + 3.8L + 0.6R) µin Glass grid reticle Stair step gage ____________________________ 1 This laboratory offers commercial calibration service and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
to 24 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7046.01) 8/05/2025 Page 2 of 2 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, and R is the resolution in microinches of the unit under test. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited RG LOEWENGUTH CO, INC. Rochester, NY for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 5th day of August 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7046.01 Valid to June 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2144 Brighton-Henrietta TL Road, Rochester, NY, 14623, US

43.15729, -77.61521

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.