Registers refreshed 2026-11-20.See refresh dates
Italy

SIDERCEM

Via Libero Grassi 7 (Area industriale Calderaro - C.P. 287), 93100, Caltanissetta, Italy

Visit website
ACCREDIA 00917ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
10
ACCREDIA certificate
1
Sites in our directory
2
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 10 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

APAT CNR IRSA 1030 Man 29 2003
APAT CNR IRSA 2090 A Man 29 2003
APAT CNR IRSA 2090 C Man 29 2003
DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 12457-2Characterisation of waste - Leaching - Compliance test for leaching of granular waste materials and sludges - Part 2: One stage batch test at a liquid to solid ratio of 10 l/kg for materials with particle size below 4 mm (without or with size reduction)
EPA 3015
EPA 3051
EPA 6020Inductively Coupled Plasma - Mass Spectrometry
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes

Certificate says EN ISO 17294-2/EPA Method 200.8. Probably the same standard; not checked against the EN document.

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.

Scope as published by ACCREDIA

4 lines
ACCREDIA

ISO/IEC 17025

Active

00917

View scope

Accredited scope, certificate 00917

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2090 A Man 29 2003; APAT CNR IRSA 2010 Man 29 2003; APAT CNR IRSA 2010 B Man 29 2003; APAT CNR IRSA 2010 A Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2090 D Man 29 2003; APAT CNR IRSA 2090 B Man 29 2003; APAT CNR IRSA 2100 Man 29 2003; APAT CNR IRSA 4090 A1 Man 29 2003; APAT CNR IRSA 4140 B Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 2050 Man 29 2003; Rapporti ISTISAN 2007/31 pag 97 Met ISS BEB027; APAT CNR IRSA 2020 A Man 29 2003; MI 01-15 rev 2 2016; APAT CNR IRSA 4020 Man 29 2003; EPA 200.8 1994; APAT CNR IRSA 3030 Man 29 2003; APAT CNR IRSA 2040 B Man 29 2003Waste water-
2APAT CNR IRSA 2090 C Man 29 2003; EPA 6020B 2014; EPA 3015A 2007; APAT CNR IRSA 3150 C Man 29 2003; APAT CNR IRSA 4010 Man 29 2003; UNI EN 12457-2:2004; EPA 6020B 2014; APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; DM 06/09/1994 GU n 288 10/12/1994 All 1 Met B; MI 02-17 rev 5 2024; UNI EN 1484:1999; UNI EN 12457-2:2004; EPA 3051A 2007; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met IV.1; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met III.1Waste water-
3UNI CEI EN ISO/IEC 17025:2018; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.2; DM 06/09/1994 GU n 288 10/12/1994 All 2 met B; DM 06/09/1994 GU n 288 10/12/1994 All 2 Met ASupporti da campionamento aria di ambienti di lavoro/Samples from air sampling of workplace air, Supporti da campionamento aria di ambienti di vita/Samples from air sampling of ambient air; Fibre aerodisperse/Airborne fibre-
4APAT CNR IRSA 1030 Man 29 2003; APAT CNR IRSA 2120 Man 29 2003; UNI CEI EN ISO/IEC 17025:2018Waste water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Libero Grassi 7 (Area industriale Calderaro - C.P. 287), Caltanissetta, 93100, IT

37.49026, 14.06328

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.