What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 7294.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7294.01) 04/17/2026 Page 2 of 4
Parameter/Equipment
Range
CMC2 (±)
Comments
Calipers
Up to 600 mm
Up to 6 in
Up to 8 in
Up to 12 in
Up to 18 in
Up to 24 in
0.014 mm
0.023 mm
0.013 mm
0.018 mm
0.022 mm
Mitutoyo caliper checker
Height Gauges
Up to 600 mm
Up to 12 in
Up to 18 in
Up to 24 in
0.023 mm
0.020 mm
0.021 mm
Mitutoyo caliper checker
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage – Generate
(0 to 600) mV
(0 to 60) V
(60 to 600) V
0.13 mV
0.019 V
0.18 V
Fluke 5080A
DC Current – Generate
Clamp On / Loop Meters
(0 to 60) mA
(60 to 400) mA
(0 to 6) A
(6 to 10) A
(0 to 600) A
0.013 mA
0.12 mA
0.0046 A
0.012 A
1.3 A
Fluke 5080A
Fluke 5080A with 30 turn coil
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate
(0 to 600) mV
(0 to 60) V
(60 to 600) V
(0 to 600) mV
(0 to 60) V
(60 to 600) V
(45 to 65) Hz
65 Hz to 1 kHz
0.29 mV
0.012 V
0.24 V
0.29 mV
0.012 V
0.24 V
Fluke 5080A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7294.01) 04/17/2026 Page 3 of 4
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate
(0 to 60) mA
(60 to 400) mA
(0 to 6) A
(6 to 10) A
(0 to 60) mA
(60 to 400) mA
(0 to 6) A
(6 to 10) A
Clamp on / Loop Meters:
(0 to 600) A
(45 to 65) Hz
65 Hz to 1 kHz
60 Hz
0.014 mA
0.12 mA
0.0061 A
0.012 A
0.014 mA
0.12 mA
0.0061 A
0.012 A
1.4 A
Fluke 5080A
Fluke 5080A with 30 turn
coil
Frequency – Generate
Loop / Clamp Ammeters
Multimeters
(45 to 65) Hz
(45 to 120) Hz
(120 to 1000) Hz
0.12 Hz
0.0032 Hz
0.032 Hz
Fluke 5080A with 30 turn
coil
Fluke 5080A
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance – Generate
Multimeters
0 Ω to 1 kΩ
(1 to 6) kΩ
(6 to 60) kΩ
(60 to 600) kΩ
600 kΩ to 10 MΩ
(10 to 40) MΩ
(100 to 190) MΩ
0.19 Ω
0.0012 kΩ
0.012 kΩ
0.12 kΩ
0.0080 MΩ
0.12 MΩ
0.46 MΩ
Fluke 5080A | ||
| 4 | - | Ionizing Radiation; Torque; ForceShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7294.01) 04/17/2026 Page 4 of 4
III. Ionizing Radiation & Radioactivity
Parameter/Equipment
Range
CMC2 (±)
Comments
Ionizing Radiation –
Reference Ionization
Chamber
(0.001 to 50)
Gy/min
1.7 mGy/min
Standard Imaging Exradin
A19 ion chamber,
SuperMAX electrometer
IV. Mechanical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Torque – Measuring
Equipment
Torque Wrenches &
Drivers
(0 to 44) lbf·in
(0 to 440) lbf·in
(0 to 4400) lbf·in
2.1 lbf·in
5.7 lbf·in
1.1 lbf·in
Imada torque wrench
checkers
Force – Measuring
Equipment
Load Cells, Force
Sensors
(0 to 250) lbf
0.21 lbf
Rice Lake dead weight set
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification. | 0 to 4400 lbf·in |
| 5 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.