Rad Source Technologies

822 Progress Industrial Blvd., 30043, Lawrenceville, GA, United States

Visit website
A2LA 7294.01ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 7294.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7294.01) 04/17/2026 Page 2 of 4 Parameter/Equipment Range CMC2 (±) Comments Calipers Up to 600 mm Up to 6 in Up to 8 in Up to 12 in Up to 18 in Up to 24 in 0.014 mm 0.023 mm 0.013 mm 0.018 mm 0.022 mm Mitutoyo caliper checker Height Gauges Up to 600 mm Up to 12 in Up to 18 in Up to 24 in 0.023 mm 0.020 mm 0.021 mm Mitutoyo caliper checker II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Generate (0 to 600) mV (0 to 60) V (60 to 600) V 0.13 mV 0.019 V 0.18 V Fluke 5080A DC Current – Generate Clamp On / Loop Meters (0 to 60) mA (60 to 400) mA (0 to 6) A (6 to 10) A (0 to 600) A 0.013 mA 0.12 mA 0.0046 A 0.012 A 1.3 A Fluke 5080A Fluke 5080A with 30 turn coil Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate (0 to 600) mV (0 to 60) V (60 to 600) V (0 to 600) mV (0 to 60) V (60 to 600) V (45 to 65) Hz 65 Hz to 1 kHz 0.29 mV 0.012 V 0.24 V 0.29 mV 0.012 V 0.24 V Fluke 5080A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7294.01) 04/17/2026 Page 3 of 4 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate (0 to 60) mA (60 to 400) mA (0 to 6) A (6 to 10) A (0 to 60) mA (60 to 400) mA (0 to 6) A (6 to 10) A Clamp on / Loop Meters: (0 to 600) A (45 to 65) Hz 65 Hz to 1 kHz 60 Hz 0.014 mA 0.12 mA 0.0061 A 0.012 A 0.014 mA 0.12 mA 0.0061 A 0.012 A 1.4 A Fluke 5080A Fluke 5080A with 30 turn coil Frequency – Generate Loop / Clamp Ammeters Multimeters (45 to 65) Hz (45 to 120) Hz (120 to 1000) Hz 0.12 Hz 0.0032 Hz 0.032 Hz Fluke 5080A with 30 turn coil Fluke 5080A Parameter/Equipment Range CMC2, 4 (±) Comments Resistance – Generate Multimeters 0 Ω to 1 kΩ (1 to 6) kΩ (6 to 60) kΩ (60 to 600) kΩ 600 kΩ to 10 MΩ (10 to 40) MΩ (100 to 190) MΩ 0.19 Ω 0.0012 kΩ 0.012 kΩ 0.12 kΩ 0.0080 MΩ 0.12 MΩ 0.46 MΩ Fluke 5080A
4-Ionizing Radiation; Torque; Force
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7294.01) 04/17/2026 Page 4 of 4 III. Ionizing Radiation & Radioactivity Parameter/Equipment Range CMC2 (±) Comments Ionizing Radiation – Reference Ionization Chamber (0.001 to 50) Gy/min 1.7 mGy/min Standard Imaging Exradin A19 ion chamber, SuperMAX electrometer IV. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Torque – Measuring Equipment Torque Wrenches & Drivers (0 to 44) lbf·in (0 to 440) lbf·in (0 to 4400) lbf·in 2.1 lbf·in 5.7 lbf·in 1.1 lbf·in Imada torque wrench checkers Force – Measuring Equipment Load Cells, Force Sensors (0 to 250) lbf 0.21 lbf Rice Lake dead weight set ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
0 to 4400 lbf·in
5ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

822 Progress Industrial Blvd., Lawrenceville, GA, 30043, US

33.95664, -83.98901

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.