Günter - Köhler - Institut für Fügetechnik und Werkstoffprüfung
Ernst-Ruska-Ring 3, 07745, Jena, Germany
- Accredited standards
- 3
- DAKKS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 13068-3
ISO 3452-1Non-destructive testing - Penetrant testing - Part 1: General principles
ISO 17636-2Non-destructive testing of welds - Radiographic testing - Part 2: X- and gamma-ray techniques with digital detectors
DIN EN ISO 3452-1 2014-09 Zerstörungsfreie Prüfung - Eindringprüfung - Teil 1; DIN EN ISO 17636-2 2013-05 Zerstörungsfreie Prüfung von Schweißverbindungen - Durchstrah- lungsprüfung - Teil 2; DIN EN 13068-3 2001-12 Zerstörungsfreie Prüfung - Radioskopische Prüfung - Teil 3; ISO 3452-1 2014-09 Zerstörungsfreie Prüfung - Eindringprüfung - Teil 1; ISO 17636-2 2013-05 Zerstörungsfreie Prüfung von Schweißverbindungen - Durchstrah- lungsprüfung - Teil 2
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
2 lines
ISO/IEC 17025
ActiveD-PL-17030-01-01
Accredited scope, certificate D-PL-17030-01-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | - | - |
| 2 | DIN EN ISO 3452-1 2014-09 Zerstörungsfreie Prüfung - Eindringprüfung - Teil 1; DIN EN ISO 17636-2 2013-05 Zerstörungsfreie Prüfung von Schweißverbindungen - Durchstrah- lungsprüfung - Teil 2; DIN EN 13068-3 2001-12 Zerstörungsfreie Prüfung - Radioskopische Prüfung - Teil 3; ISO 3452-1 2014-09 Zerstörungsfreie Prüfung - Eindringprüfung - Teil 1; ISO 17636-2 2013-05 Zerstörungsfreie Prüfung von Schweißverbindungen - Durchstrah- lungsprüfung - Teil 2 | Metal | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- SGS Analytics Germany GmbH Standort JenaJena · ~6 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Metal
- KOWUG Kommunale Wasser- und UmweltanalytikGera · ~31 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Metal
- TÜV Thüringen Anlagentechnik GmbH & Co. KG Prüflabor für GerätesicherheitArnstadt · ~45 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Metal
- SWS WerkstoffprüfungNetzschkau · ~56 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Metal
- InfraLeuna GmbH Fachbereich AnalytikLeuna · ~56 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Metal
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.