Germany

Konica Minolta Sensing Europe

Zweigniederlassung Deutschland, Utbremer Strasse 90, Bremen, Germany, Bremen, Germany

Visit website
A2LA 5324.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 5324.01 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5324.01) 4/2/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 KONICA MINOLTA SENSING EUROPE B.V. Zweigniederlassung Deutschland Utbremer Strasse 90 Bremen, GERMANY 28217 Joern Blanke Phone: +49 421 526 28950 CALIBRATION Valid To: May 31, 2027 Certificate Number: 5324.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 3: I. Optical Quantities Parameter/Equipment Range CMC2, 4 (±) Comments Illuminance – Illuminance Meters (8, 80, 800) lux 2.1 % Illuminance meter master body (calibrated reference instrument) Luminance – Luminance Meters (15, 50, 100, 150, 200, 230) cd/m2 2.2 % Luminance meter master body (calibrated reference instrument) Correlated Color Temperature (CCT) – Illuminance Meters 2856 K 22 K CCT standard (reference chroma meter) Chromaticity (x, y) – Illuminance Meters 0.4457 ≤ x ≤ 0.4488 0.4069 ≤ y ≤ 0.4078 ∆x ≤ 0.0024 ∆y ≤ 0.0025 Chromaticity standard (reference chroma meter) Chromaticity (x, y) – Luminance Meters 0.4457 ≤ x ≤ 0.4488 0.4069 ≤ y ≤ 0.4078 ∆x ≤ 0.0025 ∆y ≤ 0.0025 Chromaticity standard (reference chroma meter and radiance coefficient standard (diffuser))
2-Reflectance standard tile
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5324.01) 4/2/2025 Page 2 of 2 Parameter/Equipment Range CMC2, 4, 5 (±) Comments di:8° (SCI) Spectral Reflectance Factor (80 to 100) % 360 nm (370 to 390) nm (400 to 470) nm (480 to 720) nm 730 nm 740 nm 1.5 % 1.3 % 0.76 % 0.72 % 0.75 % 0.81 % Reflectance standard tile de:8° (SCE) Spectral Reflectance Factor (80 to 100) % 360 nm (370 to 390) nm (400 to 470) nm (480 to 720) nm 730 nm 740 nm 1.5 % 1.3 % 0.78 % 0.74 % 0.77 % 0.83 % Reflectance standard tile 45°:0° Spectral Reflectance Factor (80 to 100) % (360 to 390) nm (400 to 450) nm (460 to 720) nm 730 nm 740 nm 1.4 % R 0.89 % R 0.87 % R 0.90 % R 0.95 % R Reflectance standard tile _____________________________________________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted. 5 In the statement of CMC, R is the reflectance.
80 to 100 %
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited KONICA MINOLTA SENSING EUROPE B.V. Bremen, GERMANY for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 2nd day of April 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 5324.01 Valid to May 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Zweigniederlassung Deutschland, Utbremer Strasse 90, Bremen, Germany, Bremen, DE

53.07582, 8.80716

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.