Metcut Research

1775 Carillon Blvd., 45240, Cincinnati, OH, United States

A2LA|296.01A2LA|296.02ISO/IEC 17025Register collected 2026-08-22
Certificates
2
Scope items
8
Locations
1

Contact this laboratory

Watch this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Metcut Research?

Claim this profile to keep it accurate.

Claim this profile

Register record

A2LACollected
296.01Active
296.02Active

Certificates and scope

2
A2LA

ISO/IEC 17025

Active

296.01

View scope

Accredited scope, certificate 296.01

DisciplineMethodMatrixRange
materialsASM Handbook (Volumes 7, 9-12); ASTM F1372; ASTM E1508; AMS Handbook Volume 11; ASTM 415; ASTM E1086; ASTM E1999; ASTM E3047; MRI 700.13; ASTM E2994; ASTM E1251Iron-Based Alloy (Al, As, B, Bi, C, Ce, Co, Cr, Cu, Fe, Mg, Mo, Mn, N, Nb, Ni, P, Pb, S, Si, Sn, Ti, V, W); Nickel-Based Alloy (Al, As, B, C, Co, Cr, Cu, Fe, Mg, Mn, Mo, N, Nb, Ni, P, S, Si, Sn, Ti, V, W); Cobalt-Based (Al, C, Co, Cr, Fe, Mn, Mo, N, Nb, Ni, Si, Ti, V, W); Titanium-Based (Al, C, Cr, Fe, Mo, N, Ni, Si, Sn, V); Aluminum-Based Alloy (Al, B, Cr, Cu, Fe, Mg, Mn, Ni, Pb, Si, Sn, Ti, V, Zn, Zr); Copper-Based Alloys (Ag, C, Cu, Fe, Mn, Ni, Pb, Sb, Si, Sn, Zn)-
materialsASTM E139; ASTM E292; ASTM B934; ASTM F2328/F2328M; ASTM E18; ASTM E45; ASTM E384/E92; ASTM E3; GE: P29TF25; ASTM E340; ASTM E381; ASTM E407; ASTM E112; ASTM E1181; ASTM E930; GE: E50TF133; ASTM E1077; SAE J419; SAE J423; AMS 2380; GE: P3TF19; ASTM F2111; GE: P29TF34; ASTM B311; GE: P29TF73; GE: E50TF60; ASTM C633; GE: E50TF61; GE: E50TF65; GE: E50TF66; GE: E50TF121--320 to 2600 °F
mechanicalISO/IEC 17025:2017; ASTM E9; ASTM E209; ASTM E647; ASTM E466; ASTM E399; ASTM E1820; ASTM E606; ASTM B557; ASTM E8/E8M; ASTM E21; ASTM E1875; ISO 1143; GE: E50TF148; GE: P1TF79; Metcut MRI Series 200 Proceduresmetallic and nonmetallic materials2 to 200000 lbs
mechanical---

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

A2LA

ISO/IEC 17025

Active

296.02

View scope

Accredited scope, certificate 296.02

DisciplineMethodMatrixRange
materialsASTM D429; ASTM D1876; ASTM D3167; ASTM D1781; EN 2243-3; ASTM D790; ASTM D6272; EN 2562; ASTM C1161; ASTM C1341; GE: HSR/EPM D-003; ASTM D3171; ASTM D5229/D5229M; SACMA SRM-11; ASTM D618; ASTM D2584; ASTM D7136/D7136M; ASTM D256; ISO 180; ASTM D5528; GE: 4013367-058; GE: 4013367-059; ASTM D7905; ASTM D6671/D6671M; ASTM B117; ASTM G85; ASTM D297; ASTM D792; ASTM D1622; ASTM C271; GE: E50TF534; ASTM D570; ASTM D953; ASTM D7332; ASTM D4065; ASTM D5418; ASTM D7028; ASTM E1640; EN 6032; SACMA SRM-18R; ASTM D7426; ASTM E1356; ASTM E2602; ASTM E1269; ASTM E2716; SACMA SRM 25R; ASTM D3418; ASTM E831; ASTM E1545; ASTM E228; ASTM E1461Plastics-
materialsASTM E466; E50TF148; ASTM E606; E50TF148; ASTM E21; ASTM E8/E8M; ASTM E209; ASTM E9; ASTM D3479/D3479M; GE: HSR/EPM-D-002; ASTM D395; D695; D6641/D6641M; EN 2850; SACMA SRM-1R; ASTM D7136; D7137/D7137M; GE: 4013367-032; SACMA SRM-2; ASTM C393; D5467; D7249/D7249M; ASTM C365/C365M; ASTM D6484; ASTM C273; D3518; D3846; ISO 14129; EN 2563; SACMA SRM-7; ASTM D1002; D3165; D3983; ISO 14129; EN 2243-1; ASTM D5379; D7078/D7078M; ASTM D2344/D2344M; SACMA SRM-8; ASTM D3528; ASTM D5961/D5961M; D7248/D7248M; ASTM C393/C393M; ISO 1922; ASTM D2240; ASTM D6415/D6415M; ASTM C297/C297M; C1468; D412; D638; D1708; D3039/D3039M; D7291/D7291M; EN 2561; ISO 527; ASTM D5766/D5766M; GE: HSR/EPM D-001Metal-
mechanicalISO/IEC 17025:2017; R223--
mechanicalASTM E1237; GE: P1TF79; MRI Series 200; MRI 200.21; MRI 500.5-20; LTP-703, LTP-710metallic and nonmetallic materials-320 to 3000 °F

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

Location

1775 Carillon Blvd., Cincinnati, OH, 45240, US

39.10145, -84.51246

Open in Maps

Accreditation data collected from the A2LA register on .