Sony EMCS EMC/RF Test Laboratory, KL Branch
Lot 5, Jalan Kemajuan, Bangi Industrial Estate, 43650 Bandar Baru Bangi, Selangor, 43650, Malaysia, Selangor, Malaysia
- Accredited standards
- 10
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
VCCI-CISPR 32probably the same standard; matched by number only
ETSI EN 301 489-1Exclusion
Limits written next to it
EN 301489-1 (excluding vehicular testing)
EN 301489-1 V2.2.3 (2019-11) (excluding vehicular testing)
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 303 340
ETSI EN 303 372-2
FCC PART 15Radio Frequency Devices
ANSI C63.4:2014
47 CFR FCC Part 15B (using ANSI C63.4:2014); CISPR 22; EN 55022; CISPR 13; EN 55013; CISPR 32; EN 55032; CISPRJ 32:2017 (excluding Table A.7); ICES-003; SANS 2332; SANS 2332:2017; VCCI-CISPR 32:2016 (excluding Table A.7); EN 301489-1 (excluding vehicular testing); EN 301489-1 V2.2.3 (2019-11) (excluding vehicular testing); EN 301489-3; EN 301 489-3 V2.3.2 (2023-01); EN 301489-17; EN 301489-17 V3.2.4 (2020-09); EN 301 489-17 V3.3.1 (2024-09); EN 303 340; EN 303 340 V1.1.2 (2016-09); EN 303 372-2; EN 303 372-2 V1.2.1 (2021-06); CISPR 35 (excluding broadband impulsive conductive disturbances); CISPR 35: 2016 (excluding broadband impulsive conductive disturbances)
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active3203.05
The scope document we hold says it is valid until 2027-05-31.
Accredited scope, certificate 3203.05
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | 47 CFR FCC Part 15B (using ANSI C63.4:2014); CISPR 22; EN 55022; CISPR 13; EN 55013; CISPR 32; EN 55032; CISPRJ 32:2017 (excluding Table A.7); ICES-003; SANS 2332; SANS 2332:2017; VCCI-CISPR 32:2016 (excluding Table A.7); EN 301489-1 (excluding vehicular testing); EN 301489-1 V2.2.3 (2019-11) (excluding vehicular testing); EN 301489-3; EN 301 489-3 V2.3.2 (2023-01); EN 301489-17; EN 301489-17 V3.2.4 (2020-09); EN 301 489-17 V3.3.1 (2024-09); EN 303 340; EN 303 340 V1.1.2 (2016-09); EN 303 372-2; EN 303 372-2 V1.2.1 (2021-06); CISPR 35 (excluding broadband impulsive conductive disturbances); CISPR 35: 2016 (excluding broadband impulsive conductive disturbances) | - | to 40 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3203.05) Revised 12/17/2025 Page 2 of 3
Test Technology:
Test Method(s) 1:
Generic and Product Family
Standards (continued)
EN 55035 (excluding broadband impulsive conductive
disturbances);
EN 55035: 2017 (excluding broadband impulsive conductive
disturbances);
EN 55035: 2017 +A11: 2020 (excluding broadband impulsive
conductive disturbances);
SANS 2335 (excluding F.4,H);
SANS 2335:2018 (excluding F.4, H)
Current Harmonics IEC 61000-3-2; IEC 61000-3-2: 2018 + A1:2020;
IEC 61000-3-2: 2018+A2:2024;
EN IEC 61000-3-2: 2019;
EN IEC 61000-3-2: 2019 + A1: 2021;
EN IEC 61000-3-2: 2019+A2:2024
SANS 61000-3-2: 2009
Voltage Fluctuations and Flicker IEC 61000-3-3; IEC 61000-3-3: 2013 + A1: 2017;
IEC 61000-3-3: 2013 + A1: 2017 + A2: 2021;
EN 61000-3-3: 2013 + A1: 2019;
EN 61000-3-3: 2013 +A1: 2019 + A2: 2021;
SANS 61000-3-3: 2009
Immunity
Electrostatic Discharge IEC 61000-4-2; IEC 61000-4-2: 2008; EN 61000-4-2: 2009
Radiated Immunity IEC 61000-4-3; IEC 61000-4-3: 2006 + A1:2007 +A2: 2010;
IEC 61000-4-3: 2020;
EN 61000-4-3: 2006 +A1:2008+A2:2010;
EN IEC 61000-4-3: 2020
Electrical Fast Transient / Burst IEC 61000-4-4; IEC 61000-4-4: 2012; EN 61000-4-4: 2012
Surge Immunity IEC 61000-4-5; IEC 61000-4-5: 2014+A1: 2017;
IEC 61000-4-5: 2005; EN 61000-4-5: 2006;
EN 61000-4-5: 2014 + A1:2017
Conducted Immunity IEC 61000-4-6; IEC 61000-4-6: 2008; IEC 61000-4-6: 2013;
IEC 61000-4-6: 2023; EN 61000-4-6: 2009;
EN 61000-4-6: 2014; EN IEC 61000-4-6: 2023
Power Frequency Magnetic Field IEC 61000-4-8 (excluding short duration mode);
IEC 61000-4-8: 2009 (excluding short duration mode);
EN 61000-4-8: 2010 (excluding short duration mode)
Voltage Dips and Interruptions IEC 61000-4-11; IEC 61000-4-11: 2004;
EN 61000-4-11: 2004;
IEC 61000-4-11: 2020; EN IEC 61000-4-11: 2020
1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use
the version that immediately precedes the current version for a period of one year from the date of
publication of the standard test method, per Annex A, Part C of A2LA R101 - General Requirements-
Accreditation of Conformity Assessment Bodies. | ||
| 3 | ANSI C63.4:2014 | - | to 40000 MHz |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SONY EMCS EMC/RF TEST LABORATORY, KL BRANCH
Selangor, Malaysia
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 16th day of April 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 3203.05
Valid to May 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in Malaysia
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.