H&P Technologies

23751 Amber Ave., 48089, Warren, MI, United States

Visit website
A2LA 7472.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 7472.01 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7472.01) 5/19/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 H&P TECHNOLOGIES, INC. 23751 Amber Ave. Warren, MI 48089 Fred Arnold Phone: 586 292 3883 CALIBRATION Valid To: June 30, 2027 Certificate Number: 7472.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 5: I. Mechanical Parameter/Equipment Range CMC2,4,6 (±) Comments Torque – Measuring Equipment3 (0.5 to 5) Nm (1 to 10) Nm (2.5 to 25) Nm (7.5 to 75) Nm (18 to 180) Nm (25 to 250) Nm (50 to 500) Nm (140 to 500) Nm 0.11 % + 0.02 Nm 0.28 % + 0.032 Nm 0.21 % + 0.057 Nm 0.1 % + 0.17 Nm 0.19 % + 0.4 Nm 0.12 % + 0.53 Nm 0.11 % + 1.1 Nm 0.33 % + 2.7 Nm Torque transducer ____________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards of n early ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7472.01) 5/19/2025 Page 2 of 2 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

23751 Amber Ave., Warren, MI, 48089, US

42.49326, -83.00627

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.