Architectural Testing, Inc. (An Intertek Company)- Plano
1909 10TH STREET, SUITE 100, 75074, PLANO, TX, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Architectural Testing, Inc. (An Intertek Company)- Plano?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 7250.06Active
Accredited standards
12Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
ASTM
ASTM D228Name not checked yet
ASTM D228; ASTM D3462; ISO/IEC 17025:2017; IEC 17025; ANSI/AMCA 550 Test method for high velocity wind driven rain resistant louvers ASTM D228
ASTM D3462Name not checked yet
ASTM D228; ASTM D3462; ISO/IEC 17025:2017; IEC 17025; ANSI/AMCA 550 Test method for high velocity wind driven rain resistant louvers ASTM D228
ASTM E72Name not checked yet
ASTM E72; ASTM E283; ASTM E3311; ASTM E5461; ASTM E547
ASTM E283Name not checked yet
ASTM E72; ASTM E283; ASTM E3311; ASTM E5461; ASTM E547
ASTM E330Name not checked yet
ASTM E330; ASTM E1592; ASTM E18861; ASTM E19961; ASTM E20681
ASTM E547Name not checked yet
ASTM E72; ASTM E283; ASTM E3311; ASTM E5461; ASTM E547
ASTM E1592Name not checked yet
ASTM E330; ASTM E1592; ASTM E18861; ASTM E19961; ASTM E20681
ASTM E3311Name not checked yet
ASTM E72; ASTM E283; ASTM E3311; ASTM E5461; ASTM E547
ASTM E5461Name not checked yet
ASTM E72; ASTM E283; ASTM E3311; ASTM E5461; ASTM E547
ASTM E18861Name not checked yet
ASTM E330; ASTM E1592; ASTM E18861; ASTM E19961; ASTM E20681
ASTM E19961Name not checked yet
ASTM E330; ASTM E1592; ASTM E18861; ASTM E19961; ASTM E20681
ASTM E20681Name not checked yet
ASTM E330; ASTM E1592; ASTM E18861; ASTM E19961; ASTM E20681
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active7250.06
The scope document we hold says it was valid until 2026-05-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.
Accredited scope, certificate 7250.06
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | Mechanical Testing | ASTM D228; ASTM D3462; ISO/IEC 17025:2017; IEC 17025; ANSI/AMCA 550 Test method for high velocity wind driven rain resistant louvers ASTM D228 | Drinking water | - |
| 2 | Electrical Testing | ASTM E72; ASTM E283; ASTM E3311; ASTM E5461; ASTM E547 | Drinking water | - |
| 3 | Mechanical Testing | ASTM E330; ASTM E1592; ASTM E18861; ASTM E19961; ASTM E20681 | Ambient air | - |
| 4 | Mechanical Testing | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Associated Testing Laboratories, Inc.Sugar Land, TX · ~390 kmA2LAShares 2 accredited materialsAmbient airDrinking water
- Pace Analytical NationalMt. Juliet, TN · ~996 kmA2LAShares 2 accredited materialsAmbient airDrinking water
- NSF InternationalAnn Arbor, MI · ~1,533 kmA2LAShares 2 accredited materialsAmbient airDrinking water
- U.S. Micro-SolutionsLatrobe, PA · ~1,740 kmA2LAShares 2 accredited materialsAmbient airDrinking water
- Architectural Testing, Inc. (An Intertek Company)- FresnoFRESNO, CA · ~2,141 kmA2LAShares 2 accredited materialsAmbient airDrinking water
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.