Sieć Badawcza Łukasiewicz - Krakowski Instytut Technologiczny
ul. Zakopiańska 73, 30-418, Kraków, Poland
- Accredited standards
- 49
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 49 standard numbers and the 32 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO11
ISO 148-1Metallic materials - Charpy pendulum impact test - Part 1: Test method
ISO 945-1Microstructure of cast irons - Part 1: Graphite classification by visual analysis
ISO 6103Bonded abrasive products - Permissible unbalances of grinding wheels as delivered - Static testing
ISO 6506-1Metallic materials - Brinell hardness test - Part 1: Test method
ISO 6507-1Metallic materials - Vickers hardness test - Part 1: Test method
ISO 6508-1Metallic materials - Rockwell hardness test - Part 1: Test method
ISO 6892-1Metallic materials - Tensile testing - Part 1: Method of test at room temperature
ISO 9934-1Non-destructive testing - Magnetic particle testing - Part 1: General principles
ISO 14708-2Implants for surgery - Active implantable medical devices - Part 2: Cardiac pacemakers
ISO 15641Milling cutters for high speed machining - Safety requirements
ISO 17638Non-destructive testing of welds - Magnetic particle testing
EN9
EN 124-1
EN 847-1
EN 1083-2
EN 1369Founding - Magnetic particle testing
EN 10228-1Non-destructive testing of steel forgings - Part 1: Magnetic particle inspection
EN 12413
EN 13236
EN 13743
EN 50561-1
IEC 60601 series9
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 60601-2-4
IEC 60601-2-10
IEC 60601-2-25
IEC 60601-2-27
IEC 60601-2-31
IEC 60601-2-47
IEC 60601-2-52
CISPR8
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 12Vehicles, boats and devices with internal combustion engines or traction batteries - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
IEC 61000 series5
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC4
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 80601-2-26
IEC 80601-2-49
EN 12680 series3
EN 12680-1Founding - Ultrasonic testing - Part 1: Steel castings for general purposes
EN 12680-2
EN 12680-3Founding - Ultrasonic testing - Part 3: Spheroidal graphite cast iron castings
PN-EN ISO 148-1:2017-02
PN-EN ISO 945-1:2019-09; PN-75/H-04661; Procedura CLB2/P/001/02 wydanie z dnia 05.04.2020 r.; Procedura CLB2/P/02/01 wydanie z dnia 02.12.2020 r.
PN-93/N-01359; PN-EN ISO 6103:2015-02; PN-EN 12413:2020-03; PN-EN 847-1:2018-03; PN-EN 13236:2019-06; PN-EN 1083-2:2002; PN-EN 13743:2017-05; PN-EN ISO 15641:2004; Procedura PB-01-L1; Procedure PB-02-L1
PN-EN ISO 6892-1:2020-05; PN-EN ISO 6506-1:2014-12; PN-EN ISO 6507-1:2024-04; PN-EN ISO 6508-1:2024-06
PN-EN 124-1:2015-07; PN-EN 12680-1:2005; PN-EN 12680-2:2005; PN-EN 12680-3:2012; PN-EN ISO 9934-1:2017-02; PN-EN 1369:2013-04; PN-EN 10228-1:2016-07; PN-EN ISO 17638:2017-01
PN-EN 60601-1:2011+A11:2011; PN-EN 60601-1:2011+A1:2014-02+A12:2014-12+A2:2022-03; PN–EN 60529:2003; PN-EN IEC 60601-2-31:2020-09; ISO 14708-2:2019
PN-EN 124-1:2015-07
PN-EN 55011:2016-05/A1:2017-06; PN-EN 55011:2016-05; PN-EN 55022:2011; PN-EN 50561-1:2013 tylko punkt 4; PN-EN 55014-1:2017-06; PN-EN 55016-2-1:2014-09; PN-EN 55016-2-1:2014-09/A1:2017-12; PN-EN 55015:2019-11; PN-EN 55014-1:2017-06; PN-EN 55016-2-3:2017-06; PN-EN 55016-2-3:2017-06/A1:2020-01; PN-EN 50561-1:2013 tylko punkt 7; PN-EN 55012:2012
PN-EN 60601-1:2011+A11:2011; PN-EN 60601-1:2011+A1:2014-02+A12:2014-12+A2:2022-03
PN-EN IEC 80601-2-49:2020-03; PN-EN 60601-2-4:2011+A1:2019-12; PN-EN IEC 80601-2-26: 2020-09; PN-EN 60601-1-11:2015-09
PN-EN 60601-2-47:2015-09; PN-EN 60601-2-25:2016-01; PN-EN 60601-2-27:2014-11; PN-EN 60601-2-10:2015-07+ A1:2017-02; IEC 60601-2-10:2012-06 Ed. 2.0; PN-EN 60601-2-52:2010+AC:2011+A1:2015-07
PN-EN 61000-4-2:2011; PN-EN 61547:2009; PN-EN 55014-2:2015; PN-EN 61000-4-3:2007+A1:2008+A2:2011+ IS1:2009; PN-EN 61000-4-4:2013-05; PN-EN 61000-4-5:2010; PN-EN 61000-4-6:2014-04
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.
Scope as published by PCA
21 lines
ISO/IEC 17025
ActiveAB 197
The scope document we hold says it was valid until 2026-07-10. That date has passed, so our copy may be out of date. We downloaded it from the PCA register on 2026-03-13. Check the PCA register for the current scope.
Location
Labs with overlapping accredited scope in Poland
- Ośrodek Badań i Certyfikacji SIMPTESTCERTKatowice · ~68 kmPCAShares 2 accredited methods and materialsEN ISO 6892-1:2020-05Construction products and materials
- Laboratorium Spawalnicze "GAMMA-MONTEX"Częstochowa · ~101 kmPCAShares 2 accredited methods and materialsEN ISO 6892-1:2020-05Construction products and materials
- Machinefish Materials & Technologies Spółka z ograniczoną odpowiedzialnością Sp. k.Wrocław · ~240 kmPCAShares 2 accredited methods and materialsEN ISO 6892-1:2020-05Construction products and materials
- Metrotest Sp. z o.o.Elbląg · ~461 kmPCAShares 2 accredited methods and materialsEN ISO 6892-1:2020-05Construction products and materials
- TENSLAB Sp. z o.o.Gdańsk · ~492 kmPCAShares 2 accredited methods and materialsEN ISO 6892-1:2020-05Construction products and materials
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.