Beckman Coulter
4510 Byrd Drive, 80538, Loveland, CO, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 3436.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | See scope document |
| 2 | - | WaterShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3436.01) 04/02/2025 Page 2 of 2
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
HRLD Sensor for
Water –
Flow
Particle Size
(10 to 20) mL/min
(20 to 200) mL/min
(1.25 to 289) µm
6.8 %
4.6 %
8.0 %
Rotometer ± 3 %
Monodisperse spherical
particles ± 2.5 %
____________________________________________________
1 This laboratory offers limited commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC percent is defined as the percentage of the reading.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | See scope document |
| 3 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.