Registers refreshed 2026-11-08.See refresh dates
India

BIOMEDICAL TECHNOLOGY WING - SREE CHITRA TIRUNAL INSTITUTE FOR MEDICAL SCIENCES & TECHNOLOGY

Satelmond Palace, Poojappura, 695012, Thiruvananthapuram, India

COFRAC 1-1433ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
10
COFRAC certificate
1
Site in our directory
1
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 10 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM F619
ISO 10993-3Biological evaluation of medical devices - Part 3: Evaluation of genotoxicity, carcinogenicity, reproductive toxicity and developmental toxicitySome clauses

Limits written next to it

Génotoxicité Test for genotoxicity in vitro ISO 10993-3 §5.2.2

Some clauses. Written next to it on line 6 of COFRAC certificate 1-1433.

Génotoxicité Test for genotoxicity in vivo ISO 10993-3 §5.2.2

Some clauses. Written next to it on line 6 of COFRAC certificate 1-1433.

ISO 10993-3 (§ 5.2.2)

Some clauses. Written next to it on line 6 of COFRAC certificate 1-1433.

ISO 10993-3 (§ 5.2.2.a)

Some clauses. Written next to it on line 6 of COFRAC certificate 1-1433.

ISO 10993-3 §5.2.2

Some clauses. Written next to it on line 6 of COFRAC certificate 1-1433.

ISO 10993-4Biological evaluation of medical devices - Part 4: Selection of tests for interactions with blood
ISO 10993-5Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity
ISO 10993-6Biological evaluation of medical devices - Part 6: Tests for local effects after implantation
ISO 10993-10Biological evaluation of medical devices - Part 10: Tests for skin sensitization
ISO 10993-11Biological evaluation of medical devices - Part 11: Tests for systemic toxicity
ISO 10993-12Biological evaluation of medical devices - Part 12: Sample preparation and reference materials
ISO 10993-23Biological evaluation of medical devices - Part 23: Tests for irritation
ISO 11737-1Sterilization of health care products - Microbiological methods - Part 1: Determination of a population of microorganisms on products

Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-06.

Scope as published by COFRAC

7 lines
COFRAC

ISO/IEC 17025

Active

1-1433

The scope document we hold says it is valid until 2028-05-31.

View scope

Accredited scope, certificate 1-1433

LineMethodMatrixRange
1-Chemical and biological products, medical devices
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Convention N° 1093 LAB FORM 37 – Révision 09 – applicable au 15 octobre 2022 Page 1/8 Section Laboratoires ATTESTATION D’ACCREDITATION ACCREDITATION CERTIFICATE N° 1-1433 rév. 10 Le Comité Français d'Accréditation (Cofrac) atteste que : The French Committee for Accreditation (Cofrac) certifies that : BIOMEDICAL TECHNOLOGY WING - SREE CHITRA TIRUNAL INSTITUTE FOR MEDICAL SCIENCES & TECHNOLOGY Satisfait aux exigences de la norme NF EN ISO/IEC 17025 : 2017 Fulfils the requirements of the standard et aux règles d’application du Cofrac pour les activités d’analyses/essais/étalonnages en : and Cofrac rules of application for the activities of testing/calibration in : PRODUITS CHIMIQUES ET BIOLOGIQUES, EQUIPEMENTS MEDICAUX / DISPOSITIFS MEDICAUX - PRODUITS BIO-ACTIFS (MEDICAMENTS, COSMETIQUES, ANTISEPTIQUES ET DESINFECTANTS) CHEMICAL AND BIOLOGICAL PRODUCTS, MEDICAL DEVICES / MEDICAL DEVICES - BIOCIDES AND HYGIENE PRODUCTS (MEDICALS, COSMETICS, ANTISEPTICS AND DISINFECTANTS) réalisées par / performed by : BIOMEDICAL TECHNOLOGY WING - SREE CHITRA TIRUNAL INSTITUTE FOR MEDICAL SCIENCES & TECHNOLOGY SATELMOND PALACE, POOJAPPURA 695 012 TRIVANDRUM INDIA et précisément décrites dans l’annexe technique jointe and precisely described in the attached technical appendix L’accréditation suivant la norme internatio nale homologuée NF EN ISO/IEC 17025 est la preuve de la compétence technique du laboratoire dans un domaine d’activités clairement défini et du bon fonctionnement dans ce laboratoire d’un système de management adapté (cf. communiqué conjoint ISO- ILAC-IAF en vigueur disponible sur le site internet du Cofrac www.cofrac.fr) Accreditation in accordance with the recognised international standard NF EN ISO/IEC 17025 demonstrates the technical competence of the laboratory for a defined scope and the proper operation in this laboratory of an appropriate management system (see current Joint ISO -ILAC-IAF Communiqué available on Cofrac web site www.cofrac.fr) . Le Cofrac est signataire de l’accord multilatéral d’EA pour l’accréditation , pour les activités objets de la présente attestation. Cofrac is signatory of the European co -operation for Accreditation (EA) Multilateral Agreement for accreditation for the activities covered by this certificate.
-
2ISO 10993-12; ASTM F619Other-
3ISO 10993-23; USP/NF<88>; ISO 10993-11; ISO 10993-4Other-
4ISO 10993-4; ISO 10993-10; ISO 10993-23; ISO 10993-11; ISO 10993-6; ASTM 756; USP/NF <151>Medical devices-
5ISO 10993-4; D.5.2 A.A.B.B.; ISO 10993-4 B.3.4.1; WPTRU015Medical devices (material in blood contact/storage); Plasma-
6ISO 10993-3 §5.2.2; ISO 10993-3 (§ 5.2.2.a); OECD n° 471; ISO 10993-3 (§ 5.2.2); OECD n° 474; ISO 10993-3 (§ 5.2.2); OECD n°475; ISO 10993-5Other-
7USP en vigueur <71>; NF EN ISO 11737-1Other-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Satelmond Palace, Poojappura, Thiruvananthapuram, 695012, IN

8.48823, 76.94755

Open in Maps

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.