Registers refreshed 2026-11-20.See refresh dates
Italy

Dolomiti Energia Holding

Via Fersina 23, 38123, Trento, Italy

Visit website
ACCREDIA 00263ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
12
ACCREDIA certificate
1
Sites in our directory
2
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 12 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO8
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 11731Water quality - Enumeration of Legionella

Certificate says EN ISO 11731 2019-03 UBA Empfehlung 18, EN ISO 11731:2017. Probably the same standard; not checked against the EN document.

ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
Other standards4
APAT CNR IRSA 4020 Man 29 2003
EN 13657Characterization of waste - Digestion for subsequent determination of aqua regia soluble portion of elements
EN 17892Water quality - Determination of selected per- and polyfluoroalkyl substances in drinking water - Method using liquid chromatography/tandem-mass spectrometry (LC-MS/MS)Some clauses

Limits written next to it

UNI EN 17892:2024 - solo/only Parte

Some clauses. Written next to it on line 2 of ACCREDIA certificate 00263.

EPA 300.1

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.

Scope as published by ACCREDIA

5 lines
ACCREDIA

ISO/IEC 17025

Active

00263

View scope

Accredited scope, certificate 00263

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 11731:2017; APAT CNR IRSA 3200 A2 Man 29 2003; Rapporti ISTISAN 2007/31; MI-157 Rev.4 Anno 2025 "Acido Monocloroacetico (MCAA) - Acido Dicloroacetico (DCAA) - Acido Tricloroacetico (TCAA) - Acido Monobromoacetico (MBAA) - Acido dibromoacetico (DBAA)"; UNI EN ISO 14189:2016Drinking waterSee scope document
2UNI CEI EN ISO/IEC 17025:2018; UNI EN 17892:2024; UNI EN ISO 16266:2008; UNI EN ISO 9308-2:2014; Rapporti ISTISAN 2007/31; AFNOR IDX 33/03-10/13; APAT CNR IRSA 3030 Man 29 2003; Rapporti ISTISAN 2019/07Acque destinate al consumo umano/Drinking waters, Acque di balneazione/Bathing waters, Acque di piscina/Swimming pool waters, Acque di pozzo/Well water, Acque di scarico/Waste waters, Acque naturali (non saline)/Natural waters (not marine), Acque minerali naturali/Natural mineral waters, Acque sotterranee/Ground waters, Acque superficiali/Surface waters0.002 to µg/L
3UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 7899-2:2003; Rapporti ISTISAN 2007/31 pag 187; Met ISS CAD004; Rapporti ISTISAN 2019/07 pag 86 Met ISS CAB039; UNI EN ISO 17294-2:2023; EPA 300.1 1997 part B + EC 1999; APAT CNR IRSA 4030 C Man 29 2003; APAT CNR IRSA 4050 Man 29 2003; APAT CNR IRSA 5030 Man 29 2003; APAT CNR IRSA 4030 + 4050 + 4020 + 5030 Man 29 2003; DPGP-Trento 26/01/1987 BUR n 9 17/02/1987 Art 15 + APAT CNR IRSA 2090 B Man 29 2003; APHA Standard Methods for Examination of Water and Wastewater 4500-O G (2021); APHA Standard Methods for Examination of Water and Wastewater 5210 B (2019) + 4500-O G (2021); ISO 15705:2002; APAT CNR IRSA 2090 C Man 29 2003; APAT CNR IRSA 2090 B Man 29 2003Drinking water0.25 to 10 µg/l
4APAT CNR IRSA 8030 Man 29 2003; APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 3030 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; UNI EN ISO 10304-1:2009; UNI EN 13657:2004 par 6.1; APAT CNR IRSA 3200 A2 Man 29 2003; CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1Waste water-
5-Drinking water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Dolomiti Energia Holding S.p.A. Via Fersina 23 38123 Trento TN Allegato al certificato di accreditamento n. 00263 rev. 6 del 23/01/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 67 Sede A Data: 02/12/2025 pag. 5 di 5 ELENCO Prove Accreditate - Con Campo Flessibile Acque destinate al consumo umano/Drinking waters, Acque sotterranee/Ground waters, Acque superficiali/Surface waters, Acque/Waters, Eluati da test di cessione/Eluates from leaching test Denominazione della prova / Campi di prova Metodo di prova Tecnica di prova O&I Azoto nitrico (da calcolo)/Nitric nitrogen (calculation), Bromuri/Bromide, Cloriti/Chlorite, Cloruri/Chloride, Fluoruri/Fluoride, Fosfati/Phosphate, Nitrati/Nitrate, Nitriti/Nitrite, Solfati/Sulphates Vedere elenco dei dettagli delle prove flessibili/See list of flexible scope details IC Legenda/Note Il simbolo (1), se presente, indica: "Materiale/Prodotto/Matrice" non previsto dal metodo ma assimilabile/The symbol (1), if present, means: Material/Product/Matrix not provided for by the method but acceptable Per la definizione della “categoria" di prova indicata nel titolo, si veda il Regolamento Generale ACCREDIA RG-02/For the definition of the test “category” indicated in the title, see ACCREDIA General Regulation RG-02. Il QRcode consente di accedere direttamente al sito www.accredia.it per verificare la validità dell'elenco prove e del certificato di accreditamento rilasciato al laboratorio/The QRcode allows to directly access to the website www.accredia.it to verify the validity of the test list and of the accreditation certificate issued to the laboratory. L’eventuale simbolo “X” riportato nella colonna “O&I” indica che il laboratorio è accreditato anche per fornire opinioni e interpretazioni basate sui risultati delle specifiche prove contrassegnate/Any "X" symbol in the "O&I" column indicates that the laboratory is also accredited to provide opinions and interpretations based on the results of the specific marked tests. L'eventuale simbolo (*) indica che è attiva una sospensione dell’accreditamento per la specifica attività riportata a fianco/Any symbol (*) indicates that a suspension of accreditation is active for the specific activity shown next to it.
-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Fersina 23, Trento, 38123, IT

46.04564, 11.12042

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.