Grand Rapids Metrology
4215 Stafford Avenue, SW, 49548, Grand Rapids, MI, United States
Visit website- Scope lines
- 18
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 18 scope lines.
A2LA certificate 1489.01 · 18 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 90 ° |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 2 of 17
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Gage Balls
(0.125 to 1) in
(20 + 7D) µin
P&W Labmaster
TM, gage
block masters
Gage Blocks
(0.005 to 12) in
(3.9 + 3.0L) µin
P&W Labmaster
TM, gage
block masters
Height Gages
3
Up to 40 in
(600 + 41L) µin
Gage blocks, surface
plate
Snap Gages
(0.25 to 8) in
(18 + 7L) µin
P&W Labmaster
TM,
master rings
Bore Gage
Up to 8 in
58 µin
Master rings
Micrometers3 –
Outside
Up to 12 in
(12 to 60) in
(55 + 8L) µin
(530 + 5L) µin
Gage blocks
Optical Comparator
3 –
Axis Linearity
Magnification
Angle
Up to 12 in
(10, 20, 50, 100, 125,
250) x
Up to 90°
(260 + 0.5L) µin
(620 + 0.5L) µin
0.3°
Glass master scales,
angle blocks
Rules & Tape
Measures
3
Up to 100 ft
0.6R in
Gage blocks
Thread Plugs –
Pitch Diameter:
(0.3 to 80 TPI)
Major Diameter
Up to 4 in
Up to 4 in
(88 + 6D) µin
(13 + 8D) µin
P&W Labmaster
TM, gage
block masters, thread
wire masters
TPI = Threads per Inch | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 3 of 17
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Thread Wires
Up to 0.500 in
diameter
(31 + 6D) µin
P&W Labmaster
TM, gage
block masters, plug gage
masters
Protractors
Up to 360°
0.08°
Sine plate, gage blocks
Surface Plates
3 –
Flatness
Repeatability
Up to 144 in
Up to 144 in
(72 + 0.3L) µin
49 µin
Planekator
Repeat-o-meter
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC
2, 5, 6 (±)
Comments
DC Voltage – Generate
3
(0 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(100 to 1000) V
20 µV/V + 1 µV
11 µV/V + 2 µV
12 µV/V + 20 µV
18 µV/V + 150 µV
18 µV/V + 1.5 mV
Fluke 5522A
DC Voltage – Measure3
(0 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 9) kV
14 µV/V + 3 µV
7 µV/V + 0.3 µV
6 µV/V + 0.05 µV
10 µV/V + 0.3 µV
9 µV/V + 0.1 µV
0.12 %
Hewlett Packard
3458A opt 002
Vitrek 4700
DC Current – Measure
3
(0 to 100) nA
100 nA to 1 µA
(1 to 10) µA
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
59 µA/A + 0.4 nA
90 µA/A + 0.04 nA
66 µA/A + 0.01 nA
29 µA/A + 0.008 nA
25 µA/A + 0.005 µA
25 μA/A + 5 μA
40 μA/A + 5 μA
120 μA/A + 10 μA
Hewlett Packard
3458A opt 002 | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 4 of 17
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
DC Current – Measure
3
(cont)
(1 to 10) A
(10 to 100) A
(100 to 500) A
(500 to 1000) A
(1000 to 1500) A
0.29 %
0.29 %
1.4 %
2.9 %
4.3 %
Empro shunt w/
Agilent 3458A
DC Current – Generate
3
(0 to 330) μA
(0 to 3.3) mA
(0 to 33) mA
(0 to 330) mA
(0 to 1.1) A
(1.1 to 3) A
(0 to 11) A
(11 to 20.5) A
(20.5 to 150) A
(150 to 1000) A
0.26 % + 0.02 µA
0.029 % + 0.05 µA
0.011 % + 0.25 µA
0.024 % + 2.5 µA
0.024 % + 40 µA
0.039 % + 40 µA
0.055 % + 500 µA
0.10 % + 750 µA
0.9 %
0.89 %
Fluke 5522A
Fluke 5522A w/
5500A/coil
Resistance – Generate
3
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.33 to 1.1) GΩ
100 MΩ to 1 TΩ
41 µΩ/Ω + 0.001 Ω
30 µΩ/Ω + 0.0015 Ω
29 µΩ/Ω + 0.0014 Ω
28 µΩ/Ω + 0.002 Ω
28 µΩ/Ω + 0.002 Ω
28 µΩ/Ω + 0.02 Ω
28 µΩ/Ω + 0.02 Ω
28 µΩ/Ω + 0.2 Ω
28 µΩ/Ω + 0.2 Ω
32 µΩ/Ω + 2 Ω
33 µΩ/Ω + 2 Ω
60 µΩ/Ω + 30 Ω
0.013 % + 50 Ω
0.025 % + 2.5 kΩ
0.051 % + 3 kΩ
0.30 % + 100 kΩ
1.5 % + 500 kΩ
2.4 %
Fluke 5522A
IET HRRS-5kV
Resistance – Measure
3
(0 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
22 µΩ/Ω + 50 µΩ
18 µΩ/Ω + 0.5 µΩ
11 µΩ/Ω + 0.5 mΩ
11 µΩ/Ω + 5 mΩ
11 µΩ/Ω + 50 mΩ
19 µΩ/Ω + 2 Ω
Hewlett Packard
3458A opt 002 | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 5 of 17
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Resistance – Measure
3
(cont)
(1 to 10) MΩ
(10 to 100) MΩ
100 MΩ to 1 GΩ
61 µΩ/Ω + 100 Ω
0.052 % + 1 kΩ
0.52 % + 10 kΩ
Hewlett Packard
3458A opt 002
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Capacitance –
Generate
3
(220 to 399.9) pF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) μF
(1.1 to 3.299 99) μF
(3.3 to 10.9999) μF
(11 to 32.9999) μF
(33 to 109.999) μF
(110 to 329.999) μF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
(10 to 10 000) Hz
(10 to 10 000) Hz
(10 to 3000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.41 % + 10 pF
0.39 % + 0.01 nF
0.39 % + 0.01 nF
0.20 % + 0.01 nF
0.19 % + 0.01 nF
0.19 % + 0.01 nF
0.19 % + 0.03 nF
0.56 % + 1 nF
0.26 % + 3 nF
0.20 % + 10 nF
0.31 % + 30 nF
0.35 % + 100 nF
0.35 % + 300 nF
0.35 % + 1 μF
0.35 % + 3 μF
0.35 % + 10 μF
0.60 % + 30 μF
0.43 % + 100 μF
Fluke 5522A
AC Voltage – Generate
3
(1 to 33) mV
(33 to 330) mV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(45 Hz to 10 kHz)
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
0.10 % + 6 µV
0.042 % + 6 µV
0.046 % + 6 µV
0.12 % + 6 µV
0.39 % + 12 µV
0.95 % + 50 µV
0.042 % + 8 µV
0.032 % + 8 µV
0.033 % + 8 µV
0.046 % + 8 µV
0.094 % + 32 µV
0.22 % + 70 µV
Fluke 5522A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 6 of 17
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Generate
3
(cont)
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10 kHz
0.041 % + 50 µV
0.031 % + 60 µV
0.034 % + 60 µV
0.041 % + 50 µV
0.078 % + 130 µV
0.26 % + 600 µV
0.24 % + 650 µV
0.031 % + 600 µV
0.037 % + 600 µV
0.045 % + 600 µV
0.098 % + 1.6 mV
0.020 % + 2 mV
0.022 % + 6 mV
0.027 % + 6 mV
0.032 % + 6 mV
0.22 % + 50 mV
0.031 % + 10 mV
0.026 % + 10 mV
0.031 % + 10 mV
Fluke 5522A
AC Voltage – Measure
3
Up to 10 mV
10 mV to 10 V
(10 to 100) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
0.030 % + 3 µV
0.020 % + 1.1 µV
0.030 % + 1.1 µV
0.10 % + 1.1 µV
0.50 % + 1.1 µV
4.0 % + 2 µV
0.007 % + 0.4 mV
0.007 % + 0.2 mV
0.014 % + 0.2 mV
0.030 % + 0.2 mV
0.080 % + 0.2 mV
0.30 % + 1.0 mV
1.0 % + 1.0 mV
1.5 % + 1.0 mV
0.020 % + 4 mV
0.020 % + 2 mV
Hewlett Packard
3458A opt 002 | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 7 of 17
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Measure
3
(cont)
(10 to 100) V
(100 to 1000) V
(0.7 to 9) kV
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(50 to 60) Hz
0.020 % + 2 mV
0.035 % + 2 mV
0.12 % + 2 mV
0.40 % + 10 mV
1.5 % + 10 mV
0.040 % + 40 mV
0.040 % + 20 mV
0.060 % + 20 mV
0.12 % + 20 mV
0.30 % + 20 mV
0.15 % + 0.1 V
Hewlett Packard
3458A opt 002
Vitrek 4700
AC Current – Generate
3
(29 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.23 % + 0.1 µA
0.32 % + 0.1 µA
0.16 % + 0.1 µA
0.35 % + 0.15 µA
0.86 % + 0.2 µA
1.7 % + 0.4 µA
0.21 % + 0.15 µA
0.13 % + 0.15 µA
0.11 % + 0.1 µA
0.21 % + 0.2 µA
0.51 % + 0.3 µA
1.0 % + 0.6 µA
0.19 % + 2 µA
0.10 % + 2 µA
0.053 % + 2 µA
0.090 % + 2 µA
0.21 % + 3 µA
0.41 % + 4 µA
0.19 % + 20 µA
0.10 % + 20 µA
0.053 % + 20 µA
0.12 % + 50 µA
0.23 % + 100 µA
0.46 % + 200 µA
Fluke 5522A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 8 of 17
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Current – Generate
3
(cont)
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
Clamp-On Only:
(20.5 to 150) A
(150 to 1000) A
(20.5 to 150) A
(150 to 450) A
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(45 to 65) Hz
(65 to 440) Hz
(65 to 440) Hz
0.21 % + 100 µA
0.098 % + 100 µA
0.70 % + 1 mA
3.0 % + 5 mA
0.19 % + 100 µA
0.070 % + 100 µA
0.63 % + 1 mA
2.7 % + 5 mA
0.080 % + 2 mA
0.12 % + 2 mA
3.0 % + 2 mA
0.15 % + 5 mA
0.18 % + 5 mA
3.0 % + 5 mA
0.42 %
0.44 %
1.2 %
1.2 %
Fluke 5522A
Fluke 5522A w/
5500A/coil
AC Current – Measure3
(0 to 100) µA
(1 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
(45to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
0.40 % + 0.03 µA
0.15 % + 0.03 µA
0.060 % + 0.03 µA
0.060 % + 0.03 µA
0.40 % + 20 µA
0.15 % + 30 µA
0.060 % + 20 µA
0.030 % + 20 µA
0.060 % + 20 µA
0.40 % + 40 µA
0.55 % + 0.15 mA
0.40 % + 200 µA
0.16 % + 200 µA
Hewlett Packard
3458A opt 002 | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 9 of 17
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Current – Measure3 (cont)
(0.1 to 1) A
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
0.080 % + 200 µA
0.10 % + 200 µA
0.30 % + 200 µA
1.0 % + 400 µA
Hewlett Packard
3458A opt 002
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Oscilloscopes3 –
Square Wave Signal:
(1 kHz Input):
50 Ω Load @ 1 kHz
1 MΩ Load @ 1 kHz
DC Volt Amplitude:
50
Ω Load
1 MΩ Load
Leveled Sine Wave:
Frequency
Square Wave Signal:
(1 kHz Input):
Leveled Sine
Wave Amplitude
Flatness
(Bandwidth)
Time Marker
Rise Time
1 mV to 6.6 V
pk – pk
1 mV to 130 Vpk – pk
(0 to 6.6) V
(0 to 130) V
(0 to 1100) MHz
50 kHz (Reference)
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
5 s to 50 ms
20 ms to 1 ns
≥ 300 ps
0.19 % + 40 μV
0.08 % + 40 μV
0.19 % + 40 μV
0.04 % + 40 μV
2.3 μHz/Hz
1.6 % + 300 μV
2.7 % + 300 μV
3.1 % + 300 μV
4.7 % + 300 μV
5.4 % + 300 μV
1.2 % + 100 μV
1.6 % + 100 μV
3.1 % + 100 μV
3.9 % + 100 μV
(19 + 1000t) μs/s
1.4 μs/s
79 ps
Fluke 5522A
SC1100
t = time in seconds | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 10 of 17
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicators3 –
Pt 385, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
Pt 3916, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.06 °C
0.06 °C
0.09 °C
0.1 °C
0.1 °C
0.2 °C
0.3 °C
0.05 °C
0.05 °C
0.05 °C
0.07 °C
0.2 °C
0.2 °C
0.2 °C
0.2 °C
0.05 °C
0.06 °C
0.06 °C
0.07 °C
0.1 °C
0.1 °C
0.1 °C
0.2 °C
0.04 °C
0.04 °C
0.05 °C
0.06 °C
0.08 °C
0.08 °C
0.09 °C
0.3 °C
0.3 °C
0.06 °C
0.06 °C
0.08 °C
0.09 °C
0.1 °C
0.2 °C
0.2 °C
0.3 °C
Fluke 5522A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 11 of 17
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicators3 – (cont)
Pt 3926, 100 Ω
PtNi 385, 100 Ω
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.06 °C
0.06 °C
0.09 °C
0.2 °C
0.2 °C
0.2 °C
0.1 °C
0.1 °C
0.2 °C
0.4 °C
Fluke 5522A
Thermocouple
Simulation
3 –
Type E
Type J
Type K
Type R
Type S
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to 100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
0.52 °C
0.17 °C
0.15 °C
0.17 °C
0.22 °C
0.33 °C
0.17 °C
0.15 °C
0.18 °C
0.24 °C
0.59 °C
0.19 °C
0.17 °C
0.26 °C
0.40 °C
0.63 °C
0.43 °C
0.37 °C
0.43 °C
0.52 °C
0.40 °C
0.39 °C
0.48 °C | ||
| 12 | ASTM class 6 | - | See scope document |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 13 of 17
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Balances
3 (cont)
(200 to 1000) g
(1000 to 2000) g
(2000 to 10 000) g
(10 000 to 20 000) g
(20 000 to 40 000) g
0.002 %
0.002 %
0.002 %
0.002 %
0.002 %
Verification w/ class
1, 3 & F weights
Mass, Fixed Points
(1, 2, 3, 5) mg
(10, 20, 30, 50) mg
(100, 200, 300) mg
500 mg
1 g
2 g
(3, 4, 5) g
(10, 20) g
(30, 40) g
50 g
100 g
200 g
300 g
(400, 500) g
1 kg
(2, 3, 4) kg
5 kg
10 kg
20 kg
25 kg
(1/32, 1/16, 1/8) oz
(1/4, 1/2) oz
(1, 2) oz
4 oz
8 oz
0.001 lb
0.002 lb
0.005 lb
0.01 lb
0.02 lb
0.05 lb
0.1 lb
0.2 lb
1 lb
2 lb
(3, 4, 5) lb
10 lb
(20, 25) lb
50 lb
0.006 mg
0.006 mg
0.007 mg
0.007 mg
0.01 mg
0.01 mg
0.01 mg
0.02 mg
0.10 mg
0.10 mg
0.10 mg
0.15 mg
20 mg
20 mg
20 mg
22 mg
22 mg
270 mg
250 mg
420 mg
0.000 004 oz
0.000 005 oz
0.000 017 oz
0.000 017 oz
0.000 17 oz
0.000 000 22 lb
0.000 000 15 lb
0.000 000 2 lb
0.000 000 15 lb
0.000 000 22 lb
0.000 000 31 lb
0.000 000 57 lb
0.000 000 75 lb
0.000 021 lb
0.000 013 lb
0.000 035 lb
0.000 044 lb
0.0006 lb
0.000 93 lb
Comparison to
Class 1 standard
weights | ||
| 14 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 14 of 17
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Scales
3
Up to 200 000 lb
0.02 %
Verification w/ class
F weights
Indirect Verification of
Rockwell Hardness
Testers
3
HRC:
Low
Medium
High
HRBW:
Low
Medium
High
0.69 HRC
0.94 HRC
1.6 HRC
2.2 HRBW
0.66 HRBW
0.66 HRBW
Master blocks
Indirect Verification of
Rockwell A & N,
Hardness Testers
3
HRA:
Low
Mid
High
HR15N:
Low
Mid
High
HR30N:
Low
Mid
High
0.36 HRA
0.61 HRA
0.31 HRA
0.67 HR15N
0.58 HR15N
0.42 HR15N
0.62 HR30N
0.62 HR30N
0.68 HR30N
Master blocks
Indirect Verification of
Vickers Hardness
Testers
3
Vickers, ≤ 1 kg:
(100 to 240) HV
(241 to 600) HV
(600 to > 650) HV
3.5 HV
8.6 HV
11 HV
Master blocks
Tachometers (Non-
Contact)
3
(1 to 99 999) rpm
0.000 29 % + 0.58R
Fluke 5522A w/
LED emitter
RPM (Non-Contact) –
Measure3
(6 to 99 999) rpm
0.033 % + 0.58R
Shimpo DT-2100
tachometer | to 200000 lb |
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 15 of 17
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Temperature – Measure
3
(-200 to 0) °C
(0 to 350) °C
(350 to 704) °C
(704 to 1250) °C
(-35 to 0) °C
(0 to 150) °C
(150 to 375) °C
3.6 °C
1.7 °C
3.3 °C
5.8 °C
0.13 °C
0.13 °C
0.14 °C
Fluke 744, SLE type
T thermocouple
Fluke 744, SLE type
K thermocouple
1560 black stack,
2560 probe module,
SPRT probe
Temperature –
Thermometers,
Temperature Probes,
Measuring Equipment
3
(-80 to -35) °C
(-35 to 0) °C
(0 to 150) °C
(150 to 375) °C
0.37 °C
0.13 °C
0.13 °C
0.14 °C
1560 black stack,
2560 probe module,
SPRT probe
Infrared Temperature
Devices
0 °C
(35 to 100) °C
(100 to 200) °C
(200 to 350) °C
(350 to 500) °C
0.8 °C
1.0 °C
1.5 °C
2.7 °C
3.5 °C
Ice bath
Fluke 4181
blackbody calibrator
Relative Humidity –
Measure
(10 to 90) % RH
(90 to 98) % RH
1.8 % RH
2.6 % RH
Vaisala MI70 w/
HMP77 probe
V. Time & Frequency
Parameter/Equipment
Range
CMC
2, 8 (±)
Comments
Stopwatches & Timers
3
0.1 s to 24 hr
(+10 to -10) s/day
0.068 s
0.07 s/day
HP 53131A opt 010
timometer 4500
Frequency – Measuring
Equipment
3
(0.01 to 119.99) Hz
(120.0 to 1199.9) Hz
(1.200 to 11.999) kHz
(12.00 to 119.99) kHz
(120.0 to 1199.9) kHz
(1.200 to 2.000) MHz
0.01 % + 5 µHz
0.01 % + 5 µHz
0.01 % + 5 µHz
0.01 % + 5 µHz
0.07 % + 5 µHz
0.2 % + 5 µHz
Fluke 5522A | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 16 of 17
SATELLITE LABORATORY
GRAND RAPIDS METROLOGY, INC.
28500 Eureka Rd.
Romulus, MI 48174
Jennifer Turner Phone: 734 942 0696
I. Mechanical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Analytical Balances
3
3 mg to 300 g
0.61 mg
Verification with Class 1
weights
Balances3
(300 to 1000) g
(1000 to 2000) g
(2000 to 10 000) g
(10 000 to 20 000) g
(20 000 to 40 000) g
0.002 %
0.002 %
0.002 %
0.002 %
0.002 %
Verification with Class 1,
3 and F weights
Scales
3
(0 to 200 000) lb
0.02 %
Verification with Class F
weights
______________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC. | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1489.01) Revised 02/27/2026 Page 17 of 17
4 In the statement of CMC, R is the numerical value of the resolution of the device under test in RPM or in
pounds-force or in microinches, and L is the numerical value of the nominal length of the device measured
in inches. D is the numerical value of the nominal diameter of the device measured in inches.
5 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
6 The stated measured values are determined usin g the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
7 This scope meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calib rated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 18 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- MetroCalKentwood, MI · ~11 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Howmet Research CenterWhitehall, MI · ~74 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- International Certification Measurements, Inc. (subsidiary of Leader Corporation)Shelby Township, MI · ~89 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Consumers Energy/Laboratory ServicesJackson, MI · ~130 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - DetroitHowell, MI · ~147 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.