South Carolina Department of Public Health
8231 Parklane Road, 29223, Columbia, SC, United States
- Accredited standards
- 13
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 13 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
AOAC13
AOAC 986.33
AOAC 989.10
AOAC 990.12
AOAC 991.14
AOAC 996.08
AOAC 999.06
AOAC 2003.07
AOAC 2003.08
AOAC 2003.11
AOAC 2004.03
AOAC 2004.06
AOAC 2013.01
AOAC 2013.10
AOAC 990.12; AOAC 986.33; AOAC 989.10; BAM Chapter 14; AOAC PTM#051201; AOAC PTM#040702; BAM Chapter 16; AOAC 2003.07; AOAC 2003.08; AOAC 2003.11; BAM Chapter 4A; AOAC PTM#060903; AOAC 991.14; BAM Chapter 4; BAM Chapter 10; AOAC 999.06; AOAC 2004.06; AOAC 2013.10
BAM Chapter 5 (modified); AOAC 996.08 (modified); AOAC 2004.03 (modified); AOAC 2013.01(modified)
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active4001.01
The scope document we hold says it was valid until 2026-06-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 4001.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | AOAC 990.12; AOAC 986.33; AOAC 989.10; BAM Chapter 14; AOAC PTM#051201; AOAC PTM#040702; BAM Chapter 16; AOAC 2003.07; AOAC 2003.08; AOAC 2003.11; BAM Chapter 4A; AOAC PTM#060903; AOAC 991.14; BAM Chapter 4; BAM Chapter 10; AOAC 999.06; AOAC 2004.06; AOAC 2013.10 | Feed | - |
| 2 | BAM Chapter 5 (modified); AOAC 996.08 (modified); AOAC 2004.03 (modified); AOAC 2013.01(modified) | - | - |
| 3 | ISO/IEC 17025:2017; A2LA R204 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- South Carolina Department of Agriculture Consumer Protection Division - Laboratory ServicesWest Columbia, SC · ~3 kmA2LAShares 1 accredited materialFeed
- Core Catalyst Food SciencesGreenville, SC · ~157 kmA2LAShares 1 accredited test methodAOAC 990.12
- ALS Food Safety, LLC - Henderson, NC DivisionHenderson, NC · ~207 kmA2LAShares 1 accredited test methodAOAC 990.12
- Tyson Food Safety and Laboratory Services also doing business as WBA AnalyticalWilkesboro, NC · ~239 kmA2LAShares 1 accredited test methodAOAC 990.12
- EMSL AnalyticalMorrisville, NC · ~286 kmA2LAShares 1 accredited test methodAOAC 990.12
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.