Ledford Gage
P.O. Box 100, 227 Industrial Drive, 67110, Mulvane, KS, United States
Visit website- Accredited standards
- 1
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E18
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active1560.01
The scope document we hold says it is valid until 2027-12-31.
Accredited scope, certificate 1560.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 1 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1560.01) 10/09/2025 Page 2 of 4
Parameter/Equipment
Range CMC2, 4 (±) Comments
Optical Comparators3 –
Linearity
Up to 6 in
(220 + 3.4L) µin
Glass master scales
Indicators – Dial, Digital
Test Type
20 µin Graduation
50 µin Graduation
100 µin Graduation
500 µin Graduation
1000 µin Graduation
Up to 2 in
(19 + 1.0L + 0.6R)
µin
LabConcept
Plug Gages –
Plain, Cylindrical
Threaded, 60o
Pitch Diameter
Major Diameter
Up to 10 in
Up to 10 in
Up to 2 in
Up to 2 in
(15 + 1.7L) µin
(18 + 1.9L) µin
51 µin
28 µin
LabConcept
TULM 210
Supermicrometer™, thread
wires
Supermicrometer™
Ring Gages –
Plain, Cylindrical
Threaded, 60
o
Pitch Diameter
Up to 10 in
Up to 10 in
Up to 2 in
Up to 2 in
(17 + 1.3L) µin
(17 + 1.7L) µin
200 µin
200 µin
LabConcept
TULM 210
LabConcept
Set plug masters
Labconcept Trimos
Universal Measuring
Machines3 –
Length
Up to 80 in
(4.0 + 1.1L) µin
Optodyne laser system | to 6 in |
| 3 | ASTM E18 | - | See scope document |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1560.01) 10/09/2025 Page 4 of 4
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches,
T = torque measured value, and R is the numerical value of the resolution of the device under test in µin.
5 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 5 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Johnson Gage and InspectionWichita, KS · ~25 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- Probata CorporationEdmond, OK · ~203 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- Trescal, Inc. - Dallas, TXIrving, TX · ~518 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- Technical Maintenance, Inc. - DallasDallas, TX · ~524 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- Technical Maintenance, Inc. - COLORADO SPRINGSColorado Springs, CO · ~680 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.