Toruńskie Wodociągi Sp z o.o.
ul. Rybaki 31/35, 87-100, Toruń, Poland
- Accredited standards
- 33
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 33 standard numbers and the 33 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO24
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6058Water quality - Determination of calcium content - EDTA titrimetric method
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6332Water quality - Determination of iron - Spectrometric method using 1,10-phenanthroline
ISO 6878Water quality - Determination of phosphorus - Ammonium molybdate spectrometric method
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9280Water quality - Determination of sulfate - Gravimetric method using barium chloride
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
Show all 24
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 9377-2Water quality - Determination of hydrocarbon oil index - Part 2: Method using solvent extraction and gas chromatography
ISO 9963-1Water quality - Determination of alkalinity - Part 1: Determination of total and composite alkalinity
ISO 10301Water quality - Determination of highly volatile halogenated hydrocarbons - Gas-chromatographic methods
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10304-4Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 4: Determination of chlorate, chloride and chlorite in water with low contamination
ISO 10523Water quality - Determination of pH
ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 14911Water quality - Determination of dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography - Method for water and waste water
ISO 15061Water quality - Determination of dissolved bromate - Method by liquid chromatography of ions
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 19458Water quality - Sampling for microbiological analysis
EN6
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 1622Water quality - Determination of the threshold odour number (TON) and threshold flavour number (TFN)
EN 25663Water quality - Determination of Kjeldahl nitrogen - Method after mineralization with selenium
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
ISO 5667 series3
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 5667-6Water quality - Sampling - Part 6: Guidance on sampling of rivers and streams
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
PN-ISO 5667-10:2021-11; PN-EN 872:2007+Ap1:2007; PN-EN ISO 10523:2012; PN-ISO 9280:2002; PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010; PN-ISO 9297:1994; PN-ISO 15705:2005; PN-EN 26777:1999; PN-82/C-04576/08; PN-EN 25663:2001; PN-EN ISO 5815-1:2019-12; PN-ISO 15705:2005
PN-EN ISO 5667-6:2016-12; PN-ISO 5667-5:2017-10; PN-EN ISO 10523:2012; PN-EN ISO 7887:2012 + Ap1:2015-06; PN-EN ISO 7027-1:2016-09; PN-EN 27888:1999; PN-EN ISO 9963-1:2001+Ap1:2004; PN-ISO 6059:1999; PN-EN 26777:1999; PN-ISO 6058:1999; PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010; PN-ISO 9297:1994; PN-EN 1622:2006
PN-EN ISO 19458:2007; PN-EN ISO 6222:2004; PN-EN ISO 9308-1:2014-12 +A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 9308-2:2014-06
PN-EN ISO 14911:2002; PN-EN ISO 10304-1:2009+AC:2012; PN-EN ISO 10304-4:2022-08; PN-EN ISO 15061:2003; PN-EN ISO 11885:2009; PN-ISO 6332:2001+Ap1:2016-06; PN-EN 1484:1999; PN-EN ISO 9377-2:2003
PN-EN ISO 10301:2002; PN-EN ISO 11885:2009
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
6 lines
ISO/IEC 17025
ActiveAB 386
The scope document we hold says it is valid until 2030-02-21.
Accredited scope, certificate AB 386
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Drinking waterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 386
Scope of accreditation No. AB 386
p.o. KIEROWNIKA DZIAŁU AKREDYTACJI
BADAŃ CHEMICZNYCH
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 386 z dnia 26.11.2019 r.
Cykl akredytacji od 23.01.2026 r. do 21.02.2030 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 386 of 26.11.2019
Accreditation cycle from 23.01.2026 to 21.02.2030
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 23, 23.01.2026 1/7
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 386
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 23 z/of 23.01.2026
Nazwa i adres / Name and address
TORUŃSKIE WODOCIĄGI Sp. z o.o.
ul. Rybaki 31/35
87-100 Toruń
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- C/28/P; C/29/P;
C/30/P
- Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków / Chemical
tests and sampling of water, drinking water, sewage
- K/28/P; K/29/P - Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi /
Microbiological tests and sampling of water, drinking water
- N/28/P; N/29/P;
N/30/P
- Q/28/P; Q/29/P
- Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków
/ Physical properties and sampling of water, drinking water, sewage
- Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi / Sensory tests and
sampling of water, drinking water
Wersja strony/Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl
AB 386 | - |
| 2 | PN-EN ISO 5667-6:2016-12; PN-ISO 5667-5:2017-10; PN-EN ISO 10523:2012; PN-EN ISO 7887:2012 + Ap1:2015-06; PN-EN ISO 7027-1:2016-09; PN-EN 27888:1999; PN-EN ISO 9963-1:2001+Ap1:2004; PN-ISO 6059:1999; PN-EN 26777:1999; PN-ISO 6058:1999; PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010; PN-ISO 9297:1994; PN-EN 1622:2006 | Water | See scope document |
| 3 | PN-EN ISO 10301:2002; PN-EN ISO 11885:2009 | Water | See scope document |
| 4 | PN-EN ISO 14911:2002; PN-EN ISO 10304-1:2009+AC:2012; PN-EN ISO 10304-4:2022-08; PN-EN ISO 15061:2003; PN-EN ISO 11885:2009; PN-ISO 6332:2001+Ap1:2016-06; PN-EN 1484:1999; PN-EN ISO 9377-2:2003 | Water | See scope document |
| 5 | PN-EN ISO 19458:2007; PN-EN ISO 6222:2004; PN-EN ISO 9308-1:2014-12 +A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 9308-2:2014-06 | Water | - |
| 6 | PN-ISO 5667-10:2021-11; PN-EN 872:2007+Ap1:2007; PN-EN ISO 10523:2012; PN-ISO 9280:2002; PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010; PN-ISO 9297:1994; PN-ISO 15705:2005; PN-EN 26777:1999; PN-82/C-04576/08; PN-EN 25663:2001; PN-EN ISO 5815-1:2019-12; PN-ISO 15705:2005 | Waste water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- AQUANET Laboratorium Spółka z o.o.Poznań · ~132 kmPCAShares 5 accredited methods and materialsEN ISO 10304-1:2009+AC:2012EN ISO 19458:2007Drinking water
- LabAnalitykaBrzeg Dolny · ~233 kmPCAShares 5 accredited methods and materialsEN ISO 10301:2002ISO 5667-10:2021-11Drinking water
- Eko-Projekt W. Z. Żywczyk Spółka JawnaOstrowiec Św. · ~301 kmPCAShares 5 accredited methods and materialsEN ISO 19458:2007ISO 5667-10:2021-11Drinking water
- MS LAB Spółka z ograniczoną odpowiedzialnościąRypin · ~54 kmPCAShares 4 accredited methods and materialsEN ISO 10301:2002EN ISO 10304-1:2009+AC:2012Drinking water
- ORLEN Laboratorium S.A.Płock · ~92 kmPCAShares 4 accredited methods and materialsEN ISO 10301:2002ISO 5667-10:2021-11Waste water
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.