PerkinElmer Scientific UV Reference Material Certification
710 Bridgeport Ave., 06484, Shelton, CT, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 3112.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3112.01) 01/14/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
PERKINELMER SCIENTIFIC UV REFERENCE MATERIALS
CERTIFICATION LABORATORY
710 Bridgeport Ave.
Shelton, CT 06484
Frederic Ranoux Phone: +33633398332
CALIBRATION
Valid To: January 31, 2027 Certificate Number: 3112.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations1, 5:
I. Optical Quantities
Parameter/Equipment
Range
CMC2, 3, 4, 6 (±)
Comments
Optical Density –
Measure
(0.3 to 1.0) nominal
optical density
(440.0 to 2300) nm
0.0048 A
Certification of secondary
UV/VIS-NIR neutral
density glass photometric
standards
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to t he behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, A = Absorbance (also called optical density) a measure of the light -absorbing
ability of an object, expressed as the logarithm to base 10 of the reciprocal of the internal transmittance
(Aλ = -log10 (I/Io) where I is the intensity of light at a specified wavelength λ that has passed through a
sample (transmitted light intensity) and I0 is the intensity of the light before it enters the sample or incident
light intensity (or power). | 0.3 to 1 |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3112.01) 01/14/2025 Page 2 of 2
4 The CMC claim is smaller than that of the expanded uncertainty claim for ( NIST) as listed in the BIPM
Key Comparison Database. A2LA has evaluated the laboratory’s CMC claim and has verified this
information to be correct and appropriate.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.