Registers refreshed 2026-11-08.See refresh dates
United States

Parker Medical

43 Old Ridgebury Road, 06810, Danbury, CT, United States

A2LA 6374.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 6374.01 · 6 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6374.01) Revised 7/23/2025 Page 1 of 5 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 PARKER MEDICAL, INC. 43 Old Ridgebury Road Danbury, CT 06810 Timothy Holland Phone: 860 350 1627 CALIBRATION Valid To: June 30, 2027 Certificate Number: 6374.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Dynalyzers and High Voltage Dividers – DC High Voltage (kVp) Bipolar Monopole (Negative Polarity) Nominal Voltage Ratio: 1 k, 10 k, 100 k (5 to 100) kV (30 to 175) kV 0.022% of Voltage Ratio 0.027% of Voltage Ratio Spellman HVD-200- 1 / Keysight DAQ973A data acquisition system Spellman HVD-200- 1 / Fluke Multimeters Dynalyzers and High Voltage Dividers – Voltage Divider Frequency Response Anode Current Sensor Nominal Voltage Ratio: 1 k, 10 k, 100 k 10 Hz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 1 mA to 1 A 0.18 % of DC Voltage Ratio 0.32% of DC Voltage Ratio 1.4% of DC Voltage Ratio 0.18% Keysight DAQ973A data acquisition system / Fluke multimeter Keysight DAQ973A data acquisition system
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6374.01) Revised 7/23/2025 Page 2 of 5 Parameter/Equipment Range CMC2, 3, 5 (±) Comments Dynalyzers and High Voltage Dividers – Filament Current Sensor Nominal Voltage Ratio: 1 k, 10 k, 100 k (1 to 10) A 60 Hz to 5 kHz 5 kHz to 10 kHz 0.35% 0.79% Keysight DAQ973A Data Acquisition System / Fluke Multimeter Dynalyzer Digital Displays – Peak Voltage Anode Current Anode Current Filament Exposure Time (10 to 150) kV 1 mA to 1 A (1 to 10) A 60 Hz to 20 kHz 1 ms to 1.5 s 0.01% 0.01% 0.11% 0.02% Keysight DAQ973A data acquisition system HP Counter MAS Meter 1 mAs to 1 As 0.18% Keysight DAQ973A data acquisition system / HP counter DC Voltage – Generate Up to 330 mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V 330 V to 1.02 kV 0.0069 % + 3.5µV 0.0058 % + 5.8µV 0.0058 % + 57µV 0.0064 % + 0.58mV 0.0065 % + 1.4mV Fluke 5500A-SC600 multiproduct calibrator Resistance – Generate Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω 330 Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ 330 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ 0.014 % + 9.3mΩ 0.014 % + 17mΩ 0.001 % + 17mΩ 0.016 % + 11mΩ 0.011 % + 69mΩ 0.01 % + 73mΩ 0.01 % + 0.69Ω 0.01 % + 0.69Ω 0.013 % + 6.9Ω 0.014 % + 6.9Ω 0.017 % + 64Ω 0.018 % + 57Ω 0.069 % + 0.64kΩ Fluke 5500A SC600, multiproduct calibrator
1 to 10 A
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6374.01) Revised 7/23/2025 Page 3 of 5 Parameter/Equipment Range CMC2, 3 (±) Comments Resistance – Generate (cont.) (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ 0.12 % - 0.11kΩ 0.58 % + 6.4kΩ 0.68 % - 94kΩ Fluke 5500A SC600, multiproduct calibrator DC Current – Generate Up to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 2.2 A (2.2 to 11) A 0.015 % + 0.058µA 0.012 % + 0.29µA 0.012 % + 3.8µA 0.035 % + 51µA 0.071 % + 0.35mA Fluke 5500A SC600, multiproduct calibrator Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (1 to 33) mV (33 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.40 % + 23µV 0.17 % + 23µV 0.23 % + 23µV 0.29 % + 23µV 0.40 % + 38µV 1.2 % + 69µV 0.38 % + 36µV 0.058 % + 23µV 0.12 % + 23µV 0.18 % + 46µV 0.28 % + 0.20mV 0.81 % + 0.38mV 0.17 % + 0.29mV 0.035 % + 70µV 0.092 % + 70µV 0.16 % + 0.35mV 0.28 % + 2.0mV 0.58 % + 3.8mV 0.17 % + 2.9mV 0.046 % + 0.71mV 0.094 % + 2.6mV 0.22 % + 5.8mV 0.28 % + 0.02V Fluke 5500A SC600, multiproduct calibrator
to 11 A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6374.01) Revised 7/23/2025 Page 4 of 5 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (cont.) (33 to 330) V 330 V to 1.02 kV 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.058 % + 7.6mV 0.092 % + 19µV 0.10 % + 37µV 0.058 % + 93mV 0.23 % + 0.13mV 0.23 % + 0.66mV Fluke 5500A SC600, multiproduct calibrator AC Current – Generate (29 to 330) μA 330 μA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 2.2 A (2.2. to 11) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 10 Hz to 20 Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz 0.28 % + 0.21µA 0.14 % + 0.20µA 0.14 % + 0.29µA 0.13 % + 1.3µA 1.40 % + 0.18µA 0.23 % + 0.42µA 0.11 % + 0.41µA 0.11 % + 0.4µA 0.23 % + 0.4µA 0.69 % + 0.36µA 0.24 % + 3.4µA 0.12 % + 3.5µA 0.10 % + 3.5µA 0.23 % + 3.5µA 0.69 % + 3.5µA 0.26 % + 26µA 0.12 % + 34µA 0.12 % + 29µA 0.23 % + 34µA 0.69 % + 35µA 0.23 % + 43µA 0.23 % + 28µA 0.11 % + 80µA 0.87 % + 12µA 0.07 % + 0.1mA 0.12 % + 0.11mA 0.38 % + 0.11mA Fluke 5500A SC600, multiproduct calibrator ____________________________________________________________ 1 This laboratory offers commercial calibration services.
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6374.01) Revised 7/23/2025 Page 5 of 5 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
6

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited PARKER MEDICAL, INC. Danbury, CT for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 12th day of June 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6374.01 Valid to June 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

43 Old Ridgebury Road, Danbury, CT, 06810, US

41.39482, -73.45401

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.