What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 6374.01 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6374.01) Revised 7/23/2025 Page 1 of 5
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
PARKER MEDICAL, INC.
43 Old Ridgebury Road
Danbury, CT 06810
Timothy Holland Phone: 860 350 1627
CALIBRATION
Valid To: June 30, 2027 Certificate Number: 6374.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 4:
I. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Dynalyzers and High
Voltage Dividers –
DC High Voltage
(kVp) Bipolar
Monopole (Negative
Polarity)
Nominal Voltage Ratio:
1 k, 10 k, 100 k
(5 to 100) kV
(30 to 175) kV
0.022% of Voltage Ratio
0.027% of Voltage Ratio
Spellman HVD-200-
1 / Keysight
DAQ973A data
acquisition system
Spellman HVD-200-
1 / Fluke Multimeters
Dynalyzers and High
Voltage Dividers –
Voltage Divider
Frequency Response
Anode Current Sensor
Nominal Voltage Ratio:
1 k, 10 k, 100 k
10 Hz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
1 mA to 1 A
0.18
% of DC Voltage Ratio
0.32% of DC Voltage Ratio
1.4% of DC Voltage Ratio
0.18%
Keysight DAQ973A
data acquisition system
/ Fluke multimeter
Keysight DAQ973A
data acquisition system | ||
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6374.01) Revised 7/23/2025 Page 2 of 5
Parameter/Equipment
Range
CMC2, 3, 5 (±)
Comments
Dynalyzers and High
Voltage Dividers –
Filament Current Sensor
Nominal Voltage Ratio:
1 k, 10 k, 100 k
(1 to 10) A
60 Hz to 5 kHz
5 kHz to 10 kHz
0.35%
0.79%
Keysight DAQ973A
Data Acquisition System
/ Fluke Multimeter
Dynalyzer Digital Displays
–
Peak Voltage Anode
Current Anode
Current Filament
Exposure Time
(10 to 150) kV
1 mA to 1 A
(1 to 10) A
60 Hz to 20 kHz
1 ms to 1.5 s
0.01%
0.01%
0.11%
0.02%
Keysight DAQ973A
data acquisition system
HP Counter
MAS Meter
1 mAs to 1 As
0.18%
Keysight DAQ973A
data acquisition system
/ HP counter
DC Voltage – Generate
Up to 330 mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
330 V to 1.02 kV
0.0069 % + 3.5µV
0.0058 % + 5.8µV
0.0058 % + 57µV
0.0064 % + 0.58mV
0.0065 % + 1.4mV
Fluke 5500A-SC600
multiproduct calibrator
Resistance – Generate
Up to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330 Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
0.014 % + 9.3mΩ
0.014 % + 17mΩ
0.001 % + 17mΩ
0.016 % + 11mΩ
0.011 % + 69mΩ
0.01 % + 73mΩ
0.01 % + 0.69Ω
0.01 % + 0.69Ω
0.013 % + 6.9Ω
0.014 % + 6.9Ω
0.017 % + 64Ω
0.018 % + 57Ω
0.069 % + 0.64kΩ
Fluke 5500A SC600,
multiproduct calibrator | 1 to 10 A |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6374.01) Revised 7/23/2025 Page 3 of 5
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Resistance – Generate
(cont.)
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
0.12 % - 0.11kΩ
0.58 % + 6.4kΩ
0.68 % - 94kΩ
Fluke 5500A SC600,
multiproduct calibrator
DC Current – Generate
Up to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 2.2 A
(2.2 to 11) A
0.015 % + 0.058µA
0.012 % + 0.29µA
0.012 % + 3.8µA
0.035 % + 51µA
0.071 % + 0.35mA
Fluke 5500A SC600,
multiproduct calibrator
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
(1 to 33) mV
(33 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.40 % + 23µV
0.17 % + 23µV
0.23 % + 23µV
0.29 % + 23µV
0.40 % + 38µV
1.2 % + 69µV
0.38 % + 36µV
0.058 % + 23µV
0.12 % + 23µV
0.18 % + 46µV
0.28 % + 0.20mV
0.81 % + 0.38mV
0.17 % + 0.29mV
0.035 % + 70µV
0.092 % + 70µV
0.16 % + 0.35mV
0.28 % + 2.0mV
0.58 % + 3.8mV
0.17 % + 2.9mV
0.046 % + 0.71mV
0.094 % + 2.6mV
0.22 % + 5.8mV
0.28 % + 0.02V
Fluke 5500A SC600,
multiproduct calibrator | to 11 A |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6374.01) Revised 7/23/2025 Page 4 of 5
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
(cont.)
(33 to 330) V
330 V to 1.02 kV
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.058 % + 7.6mV
0.092 % + 19µV
0.10 % + 37µV
0.058 % + 93mV
0.23 % + 0.13mV
0.23 % + 0.66mV
Fluke 5500A SC600,
multiproduct calibrator
AC Current – Generate
(29 to 330) μA
330 μA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 2.2 A
(2.2. to 11) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
10 Hz to 20 Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
0.28 % + 0.21µA
0.14 % + 0.20µA
0.14 % + 0.29µA
0.13 % + 1.3µA
1.40 % + 0.18µA
0.23 % + 0.42µA
0.11 % + 0.41µA
0.11 % + 0.4µA
0.23 % + 0.4µA
0.69 % + 0.36µA
0.24 % + 3.4µA
0.12 % + 3.5µA
0.10 % + 3.5µA
0.23 % + 3.5µA
0.69 % + 3.5µA
0.26 % + 26µA
0.12 % + 34µA
0.12 % + 29µA
0.23 % + 34µA
0.69 % + 35µA
0.23 % + 43µA
0.23 % + 28µA
0.11 % + 80µA
0.87 % + 12µA
0.07 % + 0.1mA
0.12 % + 0.11mA
0.38 % + 0.11mA
Fluke 5500A SC600,
multiproduct calibrator
____________________________________________________________
1 This laboratory offers commercial calibration services. | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6374.01) Revised 7/23/2025 Page 5 of 5
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
PARKER MEDICAL, INC.
Danbury, CT
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 12th day of June 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6374.01
Valid to June 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.