Sweden
Radonova Laboratories AB
Södra Depågatan 2, 754 54, Uppsala, Sweden
SWEDAC|A003783-001SWEDAC|a003783-001ISO/IEC 17025Register collected 2026-09-11
Certificates
2
Scope items
8
Locations
1
Contact this laboratory
Work at Radonova Laboratories AB?
Claim this profile to keep it accurate.
Register record
- SWEDACCollected
- A003783-001Active
- a003783-001Active
Certificates and scope
2SWEDAC
ISO/IEC 17025
ActiveA003783-001
Accredited scope, certificate A003783-001
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| chemical | SS-EN ISO/IEC 17025:2018; SS-EN ISO 11665-5:2020; SS-ISO 11665-11:2016; SS-ISO 11665-4:2021; SS-ISO 11665-4:2021/EPA Protocol for the measurement of radon in homes & workplaces, May 2019; SS-ISO 11665-4:2021/ CNRPP-AL-DF | Ambient air | 10 to 1000000 Bq/m3 |
| chemical | SS-ISO 11665-4:2021/DSA; SS-EN ISO 11665-5:2020 | Ambient air | 10 to 150000 Bq/m3; kBqh/m3 |
| chemical | SS-ISO 11665-4:2021/SSM metodbeskrivning – Mätning av radon i bostäder, 2013; SS-ISO 11665-4:2021/SSM metodbeskrivning - Mätning av radon på arbetsplatser, 2021; ANSI/AARST MAH-2023; ANSI/AARTS MA-MFLB-2023 | Ambient air | 20 to 150000 Bq/m3; pCi/L |
| food | ISO 19581:2017; ISO 19581:2017/SSM metodbeskrivning - Analys av radon i vatten, 2013 | Drinking water | 0.4 to Bq |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
SWEDAC
ISO/IEC 17025
Activea003783-001
Accredited scope, certificate a003783-001
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| Chemical Testing | ISO 19581:2017 | Ambient air | 0.4 to 2500 pCi/L; Bq; Bq/kg; Bq/l |
| chemical | SS-EN ISO 11665- 5:2020/SSM metodbeskrivning - M; SS-ISO 11665-4:2021/SSM metodbeskrivning; SS-ISO 11665-4:2021/SSM metodbeskrivning - M; SS-ISO 11665-4:2021/PHE- CRCE-040:2018 Track film measurements; ISO 11665- 5:2020 | Ambient air | 10 to 100000 Bq/m3 |
| chemical | SS-EN ISO/IEC 17025:2018 Radonova Laboratories AB Uppsala Accreditation number 1489 A003783-001 Activity measurement Technical area Parameter Method Technique Measure Material Note Radon SS-EN ISO 11665-5:2020 Continuous radon monitor with semiconductor detector 10 - 100000 Bq/m3 Air SS-ISO 11665-11:2016 Track film measurements; SS-ISO 11665-4:2021 Track film measurements; SS-ISO 11665-4:2021/ CNRPP-AL-DF Track film measurements; ISO/IEC 17025:2018 Radonova Laboratories AB Uppsala Accreditation number 1489 A003783-001 Activity measurement Technical area Parameter Method Technique Measure Material Note Radon SS-EN ISO 11665-5:2020 Continuous radon monitor with semiconductor detector 10 - 100000 Bq/m3 Air SS-ISO 11665-11:2016; ISO 11665-4:2021 | Ambient air | 10 to 1000000 Bq/m3 |
| environmental | SS-ISO 11665-4:2021/EPA Protocol for the measurement of radon in homes; SS-ISO 11665-4:2021/DSA M; SS-ISO 11665- 4:2021/Inhouse method; SS-EN ISO 11665- 5:2020/SSM metodbeskrivning; ISO 11665-4:2021 | Ambient air | 10 to 150000 Bq/m3; kBqh/m3 |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in Sweden
- Eurofins PegasuslabUppsala · ~1 kmSWEDACShares 2 accredited materialsAmbient airDrinking water
- ALS ScandinaviaDanderyd · ~51 kmSWEDACShares 2 accredited materialsAmbient airDrinking water
- Mikrolab StockholmSollentuna · ~43 kmSWEDACShares 1 accredited materialDrinking water
- SGS Analytics SwedenLinköping · ~203 kmSWEDACShares 1 accredited materialDrinking water
- SGS Analytics SwedenKarlstad · ~244 kmSWEDACShares 1 accredited materialDrinking water
Accreditation data refreshed from the SWEDAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the SWEDAC entry linked above.