Registers refreshed 2026-11-20.See refresh dates
China

UL-CCIC Company

No. 2, Chengwan Road, Suzhou Industrial Park, Suzhou, 215122, People's Republic of China, Suzhou, China

Visit website

No active accreditation in the register.

Register refreshed 2026-11-20
Part of the UL Solutions group: 28 sites in our directory.

We check which accredited labs can do it and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Withdrawn

4829.01

View scope

Accredited scope, certificate 4829.01

LineMethodMatrixRange
1CFR 47, FCC Part 15B (using ANSI C63.4-2014); CFR 47, FCC Part 18 (using FCC MP-5:1986); ICES-001; ICES-003; EN 55032; BS EN 55032; ICES-005; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; BS EN IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; BS EN IEC 61000-3-3; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5; IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6; IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; BS EN IEC 61000-4-11-to 100 A/m
2EN 55024; CISPR 24; AS/NZS CISPR 24; BS EN 55024; EN 55035; CISPR 35; BS EN 55035; EN 50130-4; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 300-386; ETSI EN 300 328; MIC Notice No.88 Appendix No.43 & 44; ETSI EN 301 893; MIC Notice No.88 Appendix No.45 & 47; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-2; ETSI EN 300 330; ETSI EN 300 440; CFR 47, FCC Part 15 Subpart C; FCC Part 15 Subpart E; FCC Part 15 Subpart F; ANSI C63.10-2013; ANSI C63.10:2020; FCC Public Notice DA 00-705; FCC KDB 905462 D02 UNII DFS Compliance Procedures New Rules; KDB 905462 D07 UNII Overview v02; KDB 905462 D03 UNII Clients Without Radar Detection New Rules; KDB 905462 D04 Operational Modes for DFS Testing New Rules; KDB 905462 D06 802.11 Channel Plans New Rules; KDB 905462 D07 UNII Overview v02; RSS-GEN; RSS-247; AS/NZS 4268; RSS-210; RSS-310; IEEE C95.1; IEEE C95.3; RSS-102; IEC/EN 62479; BS EN 62479; IEC/EN 62311; BS EN IEC 62311; IEC/EN 50385; BS EN 50385; IEC/EN 50663; BS EN 50663; IEC/EN 50665; BS EN 50665--
3ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB Publication 905462 D02 (v02)-to 40000 MHz
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited UL-CCIC COMPANY LTD. Suzhou, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 28th day of June 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 4829.01 Valid to June 30, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .