Italy
ESIA s.r.l.
Via G. Ferraris 146, 80146, Napoli, Italy
ACCREDIA|00691ISO/IEC 17025Register collected 2026-08-05
Certificates
1
Scope items
6
Locations
1
Contact this laboratory
Register record
- ACCREDIACollected
- 00691Active
Certificates and scope
1ACCREDIA
ISO/IEC 17025
Active00691
Accredited scope, certificate 00691
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| chemical | UNI CEI EN ISO/IEC 17025:2018; Rapporti ISTISAN 2007/31; EPA 3005A 1992; EPA 6010D 2018; UNI EN ISO 9308-1:2017; APAT CNR IRSA 2090 A Man 29 2003; APAT CNR IRSA 4030 A2 Man 29 2003; APAT CNR IRSA 4050 Man 29 2003; APAT CNR IRSA 3150 C Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2050 Man 29 2003; APAT CNR IRSA 2080 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; UNI EN ISO 11731:2017 | Drinking water | 1.68 to 12 µS/cm |
| chemical | UNI CEI EN ISO/IEC 17025:2018; EPA 3005A 1992; EPA 6010D 2018; APAT CNR IRSA 5120 B1 Man 29 2003; APAT CNR IRSA 2090 B Man 29 2003; APAT CNR IRSA 5130 Man 29 2003; EPA 3510C 1996; EPA 8270E 2018; APAT CNR IRSA 2010 B Man 29 2003; APAT CNR IRSA 5160 A2 Man 29 2003; APAT CNR IRSA 5160 A1 Man 29 2003; UNI 10511-1:1996/A1:2000; APAT CNR IRSA 5170 Man 29 2003; Legge n 319 10/05/1976 GU n 141 29/05/1976 Tab A p.to 5 + APAT CNR IRSA 2090 B Man 29 2003; MU 1998:13; MU 2010:11; UNI EN 13284-1:2017 | Waste water | 0.0005 to mg/l |
| chemical | UNI CEI EN ISO/IEC 17025:2018; EPA 3050B 1996; EPA 6010D 2018; UNI EN 12457-2:2004; APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 5130 Man 29 2003 | Soil | 0.1 to 1288 µS/cm |
| chemical | CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008; MI001 rev.03 anno 2024; UNI EN 14039:2005; ISPRA Man 75 2011; UNI EN ISO 21528-2:2017/EC 1:2018; UNI EN ISO 4833-2:2022 | Soil | 1 to mg/Kg |
| chemical | UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 14189:2016; UNI EN ISO 8467:1997; EPA 5030C 2003; EPA 8260D 2018; APAT CNR IRSA 2020 A Man 29 2003; APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 2110 Man 29 2003; EPA 3005A 1992; EPA 6010D 2018 | Drinking water | - |
| - | APAT CNR IRSA 1030 Man 29 2003; UNI 9432:2011 + UNI EN ISO 9612:2011; UNI ISO 2631-1:2014; UNI EN ISO 5349-2:2015; DM 16/03/1998 GU n 76 01/04/1998 All B; UNI EN 12619:2013/EC1:2013; UNI EN 14792:2017; UNI EN 15058:2017; UNI EN 14789:2017; UNI EN ISO 16911-1:2013 (solo Annex A); UNI 10393:1995 cap 7.2.1; ISO 18593:2018 | Waste water | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in Italy
- BUCCIARELLI LABORATORIAscoli Piceno · ~235 kmACCREDIAShares 5 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003EN ISO 14189:2016Drinking water
- AmbienteMessina · ~309 kmACCREDIAShares 5 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008Drinking water
- AmbientaleLecce · ~331 kmACCREDIAShares 5 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008Drinking water
- CIERRE s.r.l.Arezzo · ~353 kmACCREDIAShares 5 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003EN ISO 14189:2016Drinking water
- White Lab srl - L.A.V.Rimini · ~383 kmACCREDIAShares 5 accredited methods and materialsCNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008EPA 6010D 2018Drinking water
Accreditation data collected from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.