Registers refreshed 2026-11-08.See refresh dates
Germany

Framatome GmbH Technical Center, Thermohydraulik und Komponententests

Paul-Gossen-Straße 100, 91052, Erlangen, Germany

DAKKS D-PL-21039-02-00DAKKS D-PL-21039-02-01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
7
DAKKS certificates
2
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

DAKKS certificate D-PL-21039-02-00 · 1 line

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS certificate D-PL-21039-02-01 · 6 lines

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001--
2-components and systems of power or process plants
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Annex to the Accreditation Certificate D-PL-21039-02-01 Valid from : 04.08.2025 Date of issue : 04.08.2025 page 2 of 6 This document is a translation. The definitive version is the original German annex to the accreditation certificate. Tests in the fields: thermal, fluidic and process-engineering investigations and diagnostics of components and systems of power or process plants under operational and accident conditions as well as type and repeated in-service tests Flexible Scope of Accreditation: Within the indicated test areas the testing laboratory is permitted without being required to prior inform and obtain approval from DAkkS [Flex C] to modify, develop or further develop test methods. The test methods listed are examples. The testing laboratory has an up-to-date list of all test methods within the flexible scope of accreditation. The list is publicly available on the website of the testing laboratory. The used test methods are identified with the symbols of the locations stated below: ER = Erlangen KA = Karlstein
-
3FAW T-1001 (ER, KA); FAW T-3036 (KA); FAW T-3021 (KA); FAW T-3009 (KA); Quality management manual FAW T-0001components and systems of power and process plant technology; devices, facilities and components of power and process plants-
4FAW-T-1001; FAW-T-3009; FAW-T-3021; FAW-T-3036--
5FAW T-2001; FAW T-3006; FAW T-0001Components and systems of power and process plants-
6FAW T-2003 (ER); FAW T-0001; DIN; EN; IEC; ISOcomponents of power and process plants; Valves of all types (e.g. safety valves, check valves, diaphragm valves) with actuators (e.g. elektrical, solenid, pneumatic, SIEKA), safety valves, pilot valves, components of nuclear auxiliary systems (e.g. pumps, condensators) and comparable facilities in installed or work shop conditions – or comparable components-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Paul-Gossen-Straße 100, Erlangen, 91052, DE

49.57591, 11.00845

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.