Timet UK
No.1 Plant, Holford Drive, Witton, Birmingham, B42 2TU, West Midlands, United Kingdom
Visit website- Accredited standards
- 11
- UKAS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the UKAS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 11 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM7
ASTM E8Standard Test Methods for Tension Testing of Metallic Materials
ASTM E21Standard Test Methods for Elevated Temperature Tension Tests of Metallic Materials
ASTM E139
ASTM E292
ASTM E539
ASTM E1447
ASTM E2371
ISO4
ISO 204Metallic materials - Uniaxial creep testing in tension - Method of test
ISO 6506-1Metallic materials - Brinell hardness test - Part 1: Test method
ISO 6892-1Metallic materials - Tensile testing - Part 1: Method of test at room temperature
ISO 6892-2Metallic materials - Tensile testing - Part 2: Method of test at elevated temperature
BS EN ISO 6892-1:2019 ASTM E8/E8M16; BS EN ISO 6892-2:2018 ASTM E21-17; BS EN ISO 204:2018 ASTM E139-11; BS EN ISO 204:2018 ASTM E139-11 ASTM E292-18; BS EN ISO 6506-1:2014
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; ASTM E539; ASTM E2371; ASTM E1447
Read from the scope as published by UKAS. Register refreshed 2026-11-06.
Scope as published by UKAS
3 lines
ISO/IEC 17025
Active0090
Accredited scope, certificate 0090
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | Metal | - |
| 2 | BS EN ISO 6892-1:2019 ASTM E8/E8M16; BS EN ISO 6892-2:2018 ASTM E21-17; BS EN ISO 204:2018 ASTM E139-11; BS EN ISO 204:2018 ASTM E139-11 ASTM E292-18; BS EN ISO 6506-1:2014 | Metal | to 1000 °C |
| 3 | ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; ASTM E539; ASTM E2371; ASTM E1447 | TITANIUM and Titanium Alloys | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
No.1 Plant, Holford Drive, Witton, Birmingham, West Midlands, B42 2TU, GB
52.52108, -1.89186
Open in MapsLabs with overlapping accredited scope in United Kingdom
- Oracle Test Laboratory part of LoneStar Fasteners HydroboltWest Midlands · ~10 kmUKASShares 1 accredited materialMetal
- WQ Inspection & CertificationWest Midlands · ~10 kmUKASShares 1 accredited materialMetal
- BES Group Testing RotechWest Midlands · ~11 kmUKASShares 1 accredited materialMetal
- Element Materials Technology Aerospace UKWest Midlands · ~14 kmUKASShares 1 accredited materialMetal
- RMR Materials Testing CoWest Midlands · ~16 kmUKASShares 1 accredited materialMetal
Accreditation data refreshed from the UKAS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.