Registers refreshed 2026-11-20.See refresh dates
United Kingdom

EUROFINS E&E CML

Newport Business Park, New Port Road, CH65 4LZ, Ellesmere Port, United Kingdom

Visit website
UKAS 8175ISO/IEC 17025Register refreshed 2026-11-20
Part of the Eurofins group: 318 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
27
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

Our reading of the UKAS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 27 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60079 series10
IEC 60079-0
IEC 60079-1
IEC 60079-2
IEC 60079-5
IEC 60079-15
IEC 60079-18
IEC 60079-25
IEC 60079-31
IEC 60079-35-1
IEC 60079-35-2
EN6
EN 1755
EN 13012
EN 13616
EN 13760
EN 14678-1
EN 14986
EN 13617 series4
EN 13617-1
EN 13617-2
EN 13617-3
EN 13617-4
IEC 60068 series3
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ISO 80079 series3
ISO 80079-36Explosive atmospheres - Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements
ISO 80079-37Explosive atmospheres - Part 37: Non-electrical equipment for explosive atmospheres - Non-electrical type of protection constructional safety ''c'', control of ignition sources ''b'', liquid immersion ''k''
ISO/IEC 80079-38Explosive atmospheres - Part 38: Equipment and components in explosive atmospheres in underground mines
Other standards1
IEC 60529Degrees of protection provided by enclosures (IP Code)

Read from the scope as published by UKAS. Register refreshed 2026-11-20.

Scope as published by UKAS

8 lines
UKAS

ISO/IEC 17025

Active

8175

View scope

Accredited scope, certificate 8175

LineMethodMatrixRange
1ISO/IEC 17025:2017--
2EN 1755:2000; EN 1755:2015; EN 13012:2001; EN 13616:2004; EN 13617-1:2012; EN 13617-1:2004; EN 13617-2:2012; EN 13617-2:2004; EN 13617-3:2012; EN 13617-3:2004; EN 13617-4:2004; EN 13760:2003; EN 14678-1:2006; EN 14986:2007; EN 14986:2017Petroleum products-
3BS EN IEC 60068-2-30:2005 BS EN IEC 60068-2-78:2013 GB/T2423; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60079-0; IEC 60068-2-1Electrical Apparatus, Systems, Components, Accessories and Enclosures for use in potentially Explosive Atmospheres; Electrostatic hand-held spraying equipment; Stationary electrostatic application equipment for ignitable liquid coating material; Stationary electrostatic application equipment for ignitable coating powders; Stationary electrostatic application equipment for ignitable flock material; Group 1 Category M1 Equipment; Electrical apparatus for potentially explosive atmospheresSee scope document
4ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60079-1; IEC 60079-2; IEC 60079-5Oil-
5ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60079-15; IEC 60079-18; IEC 60079-25Electrical Apparatus, Systems, Components, Accessories and Enclosures for use in potentially Explosive Atmospheres-
6ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60079-31; IEC 60079-35-1; IEC 60079-35-2Electrical Apparatus, Systems, Components, Accessories and Enclosures for use in potentially Explosive Atmospheres; Caplights for use in mines susceptible to firedamp; Electrical apparatus for use in the presence of combustible dust; Electrical resistance trace heating systems for industrial and commercial applications; Cable glands for electrical installations-
7ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO IEC 80079-38:2016; ISO 80079-36: 2016 ISO 80079-36: 2016 Explosive atmospheres -Part 37; ISO 80079-37:2016 ISO 80079-37:2016; IEC 17025Non-electrical equipment for potentially explosive atmospheres-
8ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60529waterSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Newport Business Park, New Port Road, Ellesmere Port, CH65 4LZ, GB

53.27141, -2.87239

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.