A2LA 7585.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 7585.01 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7585.01) 11/17/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 UT MD ANDERSON CANCER CENTER 1515 Holcombe Boulevard Room B1.4832 Houston, TX 77030 Stephanie Lampe Phone: 713 792 3233 CALIBRATION Valid To: December 31, 2027 Certificate Number: 7585.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 4: I. Ionizing Radiation & Radioactivity Parameter/Equipment Range CMC2, 3 (±) Comments Thimble Ionization Chambers – 60Co: Air Kerma / Exposure 60Co: Absorbed Dose 1 Gy/min / 100 R/min 1 Gy/min 1.3 % 1.3 % Reference & field class instruments Well-Ionization Chambers – LDR: 137Cs LDR: 125I, 103Pd, 131Cs LDR: 192Ir Up to 150 U (0.2 to 25) U LDR 2.3 % 2.3 % 2.3 % Reference & field class instruments
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7585.01) 11/17/2025 Page 2 of 2 Parameter/Equipment Range CMC2, 3 (±) Comments Radioactive Sources – LDR: 137Cs LDR: 125I, 103Pd, 131Cs LDR: 192Ir Up to 150 U (0.2 to 25) U LDR 2.3 % 2.3 % 2.3 % Single sources Electrometers – Charge Current (0.1 to 600) nC 5 pA to 1000 nA 0.26 % 0.26 % Therapy: to interface with either thimble or well-ionization chambers ___________________________________________ 1 This laboratory is conditionally available for commercial service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1515 Holcombe Boulevard, Room B1.4832, Houston, TX, 77030, US

29.75894, -95.36770

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.