UT MD Anderson Cancer Center
1515 Holcombe Boulevard, Room B1.4832, 77030, Houston, TX, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 7585.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7585.01) 11/17/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
UT MD ANDERSON CANCER CENTER
1515 Holcombe Boulevard
Room B1.4832
Houston, TX 77030
Stephanie Lampe Phone: 713 792 3233
CALIBRATION
Valid To: December 31, 2027 Certificate Number: 7585.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations1, 4:
I. Ionizing Radiation & Radioactivity
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Thimble Ionization Chambers –
60Co: Air Kerma / Exposure
60Co: Absorbed Dose
1 Gy/min / 100 R/min
1 Gy/min
1.3 %
1.3 %
Reference & field
class instruments
Well-Ionization Chambers –
LDR: 137Cs
LDR: 125I, 103Pd, 131Cs
LDR: 192Ir
Up to 150 U
(0.2 to 25) U
LDR
2.3 %
2.3 %
2.3 %
Reference & field
class instruments | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7585.01) 11/17/2025 Page 2 of 2
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Radioactive Sources –
LDR: 137Cs
LDR: 125I, 103Pd, 131Cs
LDR: 192Ir
Up to 150 U
(0.2 to 25) U
LDR
2.3 %
2.3 %
2.3 %
Single sources
Electrometers –
Charge
Current
(0.1 to 600) nC
5 pA to 1000 nA
0.26 %
0.26 %
Therapy: to interface
with either thimble
or well-ionization
chambers
___________________________________________
1 This laboratory is conditionally available for commercial service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.