Registers refreshed 2026-11-08.See refresh dates
United States

Function Compliance Services

Morrison, CO, United States

A2LA 6716.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 6716.01 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6716.01) 03/19/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 FUNCTION COMPLIANCE SERVICES 4285 S. Eldridge St. Morrison, CO 80465 Carl Bjork Phone: 303 859 3354 CALIBRATION Valid To: December 31, 2026 Certificate Number: 6716.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Electrical – RF/Microwave Parameter/Equipment Range CMC2 (±) Comments Temperature Simulation3 -30 °C 0 °C 20 °C 60 °C -10 °F 32 °F 72 °F 140 °F 0.19 °C 0.19 °C 0.19 °C 0.19 °C 0.34 °F 0.34 °F 0.34 °F 0.34 °F Cooper Atkins 9320TT II. Thermodynamics Parameter/Equipment Range CMC2, 4, 6 (±) Comments Temperature3 – Measuring Equipment (-200 to -80) °C (-80 to 0) °C (0 to 125) °C (-328 to -112) °F (-112 to 32) °F (32 to 257) °F (0.0012T + 0.0082) °C (0.001T + 0.17) °C (0.0006T + 0.17) °C (0.0012T + 0.0241) °F (0.001T + 0.274) °F (0.0006T + 0.287) °F Fluke thermometer with class A RTD
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6716.01) 03/19/2025 Page 2 of 2 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Temperature3 – Measuring Equipment (cont) (-30 to 65) °C (-20 to 150) °F 0.40 °C 0.74 °F Type K thermocouple thermometer Parameter/Equipment Range CMC2, 4, 6 (±) Comments Humidity3 – Measuring Equipment (10 to 95) % RH (0.0067H + 1.47) % RH Rotronics Hygropalm HP32 / HC2A-S ___________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavi or of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 In the statement of CMC, T is the numerical value of temperature measured, H is the numerical value of humidity measured.
-30 to 65 °C
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited FUNCTION COMPLIANCE SERVICES Morrison, CO for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 19th day of March 2025. _______________________ Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6716.01 Valid to December 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.