TÜV Informationstechnik GmbH Unternehmensgruppe TÜV NORD Prüflabor für IT-Qualität
Am TÜV 1, 45307, Essen, Germany
Visit website- Accredited standards
- 3
- DAKKS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
IEC 15408
ISO 15408
ISO/IEC 18045Information security, cybersecurity and privacy protection - Evaluation criteria for IT security - Requirements and methodology for IT security evaluation
ISO/IEC TS 23532-1:2021; ISO/IEC 15408; IEC 15408
ISO/IEC 15408:2022; ISO/IEC 18045:2022
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
8 lines
ISO/IEC 17025
ActiveD-PL-12022-01-00
Accredited scope, certificate D-PL-12022-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; VO2019/881; EMVCo Security Evaluation Process | Produkten aus dem Bereich der Informations- und Kommunikationstechnik (ICT) | - |
| 2 | ISO/IEC 15408:2022; ISO/IEC 18045:2022 | - | - |
| 3 | - | N1, N2, N3, N4, N5, N6, N7, N8, N9; H1, H2, H3, SC, SBShow page textExtracted from the scope document; tables may not line up. View scope for the original. Anlage zur Akkreditierungsurkunde D-PL-12022-01-00
Gültig ab: 19.02.2025
Ausstellungsdatum: 19.02.2025 Seite 3 von 8
Die Prüfungen erfolgen bei nachfolgenden Technologien und anhand nachfolgender Assurance
Families. Alle Protection Profiles, deren Anforderungen gleich hoch sind wie oder unter den hier
gelisteten EAL Niveaus liegen, können bewertet werden. Etwaige Anforderungen an die Assurance
Class „Life-cycle support“ (ALC) innerhalb eines Protection Profiles sind dabei nicht zu berücksichtigen.
Die Assurance Class ALC wird nicht durch das Prüflabor als akkreditierte Leistung erbracht, die
Ergebnisse sind jedoch in die weiterführenden Prüfung zu integrieren.
Zulässige
Assurance Family
Prüfungen
Prüfobjektgruppen (Target of
Evaluation)
Maximales
Assurance Family
Level
Ausreichend
für EAL
(informativ)
ACE_INT S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 -
ACE_ CCL S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 -
ACE_SPD S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 -
ACE_OBJ S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
2 -
ACE_ ECD S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 -
ACE_REQ S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
2 -
ACE_MCO S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 -
ACE_CCO S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 -
APE_INT S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 -
APE_CCL S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 -
APE_SPD S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 -
APE_OBJ S1, S2, S3, S4, S5, S6, S7 2 - | - |
| 4 | - | N1, N2, N3, N4, N5, N6, N7, N8, N9; H1, H2, H3, SC, SB; S1, S2, S3, S4, S5, S6, S7Show page textExtracted from the scope document; tables may not line up. View scope for the original. Anlage zur Akkreditierungsurkunde D-PL-12022-01-00
Gültig ab: 19.02.2025
Ausstellungsdatum: 19.02.2025 Seite 4 von 8
Zulässige
Assurance Family
Prüfungen
Prüfobjektgruppen (Target of
Evaluation)
Maximales
Assurance Family
Level
Ausreichend
für EAL
(informativ)
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
APE_ECD S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 -
APE_REQ S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
2 -
ADV_ARC S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 EAL7
ADV_FSP S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
6 EAL7
ADV_IMP S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
2 EAL7
ADV_INT S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
3 EAL7
ADV_SPM S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 EAL7
ADV_TDS S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
6 EAL7
ADV_COMP S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 EAL7
AGD_OPE S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 EAL7
AGD_PRE S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 EAL7
ASE_INT S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 EAL7
ASE_CCL S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
H1, H2, H3, SC, SB
1 EAL7
ASE_SPD S1, S2, S3, S4, S5, S6, S7
N1, N2, N3, N4, N5, N6, N7, N8, N9
1 EAL7 | - |
| 5 | EUCC SCHEME STATE-OF-THE-ART DOCUMENT ACCREDITATION OF ITSEFs FOR THE EUCC SCHEME Version 1.6c | - | - |
| 6 | ISO/IEC TS 23532-1:2021; ISO/IEC 15408; IEC 15408 | - | - |
| 7 | ISO/IEC 15408:2022; ISO/IEC 18045:2022 | - | - |
| 8 | DIN; EN; IEC; ISO | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- SEWA Laborbetriebsgesellschaft mbHEssen · ~4 kmDAKKSShares 1 accredited test methodDIN
- Verein des Hygiene-Instituts des Ruhrgebiets e.V. Hygiene-Institut des Ruhrgebiets Institut für Umwelthygiene und ToxikologieGelsenkirchen · ~5 kmDAKKSShares 1 accredited test methodDIN
- AKUVIB Engineering and TestingBochum · ~9 kmDAKKSShares 1 accredited test methodDIN
- Techno LaborBottrop · ~10 kmDAKKSShares 1 accredited test methodDIN
- ALBO-tec Technologiezentrum für Analytik und Bodenmechanik Gesellschaft mit beschränkter HaftungMülheim an der Ruhr · ~11 kmDAKKSShares 1 accredited test methodDIN
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.